1.0 Description
The DS820i and DS820iT Series are high performance TriTech Passive Infrared (PIR)/Microwave (MW) Intrusion Detectors which use advanced signal
processing to provide outstanding catch performance and unsurpassed false alarm immunity. They are designed to detect movement of a human body in the
interior of a structure as it moves across the Detector’s field of view. When motion is detected, the Detector sends an alarm signal to the control panel. With
Bosch Security Systems Pet Friendly® pet immunity, these Detectors will not detect a dog up to 100 pounds (45 kg) or two 60 pound (27 kg) dogs, up to 10 cats,
numerous rodents or flying birds. This pet immunity feature has not been tested by Underwriters Laboratories.
• Input Power: 6 to 15 VDC, 16 mA nominal standby (up to 35 mA
during walk testing and alarm). Use only Limited Power
Source up to 5 A maximum.
• Standby Power: No internal standby battery. For UL Certificated
installations, 4 hours (64 mAh) standby power must
be provided by the control unit or by a Listed burglary
power supply.
• Alarm Relay: Silent operating Normally Closed reed relay. Contacts
rated 3 W, 125 mA, 28 VDC maximum for DC
resistive loads; and protected by a 4.7 Ω, 1/2 W
resistor in the common “C” leg of the relay. Do not
use with capacitive or inductive loads.
• Temperature: The storage and operating temperature range is
-40°F to +120°F (-40°C to +49°C). For UL Certificated
installations, the temperature range is +32°F to +120°F
(0°C to +49°C).
•Microwave Frequency:
DS820i/820iT: 10.525 GHz (UL Listed)
DS820iTA: 10.687 GHz (Export only, not UL Listed)
DS820iTB: 9.9 GHz (Export only, not UL Listed)
•Coverage: 20 ft. by 20 ft. (6 m by 6 m)
•Tamper: (“T” models only) Normally Closed (with cover on).
Contacts rated at 28 VDC, 125 mA max. Connect
tamper circuit to a 24-hour protection circuit.
•Options: B335LowProfileSwivelMountBracket,B338Ceiling
Mount Bracket. (The use of brackets is not
recommended for pet applications and may reduce
range and increase dead zone areas).
• Reading Bosch Security Systems, Inc. Product Date Codes
For Product Date Code information, refer to the Bosch Security Systems,
Inc. Web site at: http://www.boschsecurity.com/datecodes/
3.2 Press the vertical adjust tab
toward the side of the base and
lift out the board.
LED ON
7.5-9ft
7.5-9ft
3.3 Select a mounting location.
Mountthe sensorwhere an
intruder will most likely cross
throughthecoverage pattern.
3.5 Observe the Pet Immunity mounting recommendations.
Pet
Immune
Area
NO
OK
NOTE: The upper areas are
not pet immune.
7.5 -9 ft.
(2.3 - 2.7 m)
Mount the detector 7.5 to 9 feet
(2.3 to 2.7 meters) above the floo
r
Installation Instructions
DS820i/DS820iT Series
TriTech PIR/Microwave Intrusion Detectors with Pet Immunity
Don't point where pets can climb.
2.0 Specifications
3.0 Installation
3.1 Remove the cover using
asmall flat-blade
screwdriver.
3.4 Avoid:
Bottom of Detector
Insert screwdriver here or here
Optional anti-tamper
screws at each end
Moving Objects
Heat
Sources
Windows
and
Uninsulated
Walls
Direct Hot or
Cold
Drafts
Mounting
Outdoors
Direct Sunlight
Air
Conditioning
Outlets
2/11
DS820i/DS820iT Series Installation Instructions
P/N: F01U035073-11 Page 2
© 2011 Bosch Security Systems, Inc.
130 Perinton Parkway, Fairport, New York 14450
www.boschsecurity.com
3.6 Wire the detector. 3.7 Snap the board into the base so
the notch aligns with the tab.
3.8 Select LED operation.
LED ON
7.5-9ft
7.5-9ft
7.5-9ft
LED ON
LED ON
7.5-9ft
7.5-9ft
ON OFF
3.11 Walk test the detector. Perform this
test at the time of installation and
annuallythereafter.
3.10 Microwave range is pre-set. Field
adjustment is not required.
NOTE: If you choose to adjust the range, set
the adjustment as low as possible for
proper catch performance. Be sure to
walk test throughout the coverage
pattern after any adjustment.
3.9 In non-pet applications only, if
look-down is desired, peel away
the look-down mask. Do not
remove the clear plastic lens.
LED ON
7.5-9ft
7.5-9ft
INCREASE
LED ON
7.5-9ft
7.5-9ft
Peel away
the mask
4.0 Coverage Patterns
5.0 FCC Notice
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference, including interference that may cause undesired operation.
Changes or modifications not expressly approved by Bosch Security Systems can void the user’s authority to operate the equipment.
Although generally not
required, the lens
diagram shows the
appropriate areas to
be masked. Use an
opaque material (such
as, electrical tape) to
mask the desired
areas.
0
10
10 200 Feet
6
0Meters
10 3
3
0
1234
5
6
7
8
9
10
11
This detector contains an environmental
stabilization circuit which requires
approximately 2 minutes after initial
power-up to warm up. During this time
the detector will not respond to any
movement.
Please wait 2 minutes after initial power-up
to perform any walk tests.
G
r
een = PIR detect
Yellow = MW detect
Red = Alarm
DS820i Lens
(inside view)
1234567891011
12 22
23 33
34 44
45 55
56 66
67 77
Microwave
Coverage
PIR
Coverage
Microwave
Coverage
PIR
Coverage
3.5 Mount the detector.
NOTE: To avoid possible circuit board damage, use
only the mounting hardware provided in the
appropriate
punch-out
mounting
holes.
Do not use
excessive
force when
adjusting the
microwave
pot.
0
0020
6310 Meters
Feet
0
10
7.5
Look
Down 67-
77 56-
66 45-
55 34-
44 23-
33 12-
22 1-
11
NOTE: UseonlyLimitedPower Source
up to 5 A maximum.
Remove
Don't overtighten the mounting screws
Cover may not attach correctly
Corner Mount
Surface
Mount
Thinwall knockouts
for wiring
=
7.5 - 9 ft.
(2.3 - 2.7 m)
Areas
if using the
B335 Bracket
Do not use
the B335
Bracket in
pet
applications
LED
+
-
6-15
VDC Alarm
Contacts
Tamper
Contacts
Normally Closed contacts
(DS820iT
only)

This manual suits for next models

1

Other Bosch Security Sensor manuals

Bosch Blue Line Gen2 ISC-BPR2 User manual

Bosch

Bosch Blue Line Gen2 ISC-BPR2 User manual

Bosch ISC-CDL1-W15H User manual

Bosch

Bosch ISC-CDL1-W15H User manual

Bosch ISN?SM?80 User manual

Bosch

Bosch ISN?SM?80 User manual

Bosch DS778 User manual

Bosch

Bosch DS778 User manual

Bosch F220 User manual

Bosch

Bosch F220 User manual

Bosch DS820 User manual

Bosch

Bosch DS820 User manual

Bosch ISC-SM-90 User manual

Bosch

Bosch ISC-SM-90 User manual

Bosch FCS-LWM-1 User manual

Bosch

Bosch FCS-LWM-1 User manual

Bosch TriTech+ Professional ISC-PDL1-WAC30G User manual

Bosch

Bosch TriTech+ Professional ISC-PDL1-WAC30G User manual

Bosch DS940 User manual

Bosch

Bosch DS940 User manual

Bosch DS1109i Operating instructions

Bosch

Bosch DS1109i Operating instructions

Bosch DS9360 User manual

Bosch

Bosch DS9360 User manual

Bosch ISP-SM90-120 User manual

Bosch

Bosch ISP-SM90-120 User manual

Bosch CS LD 1.0 User manual

Bosch

Bosch CS LD 1.0 User manual

Bosch ISP-PPR1-WA16K User manual

Bosch

Bosch ISP-PPR1-WA16K User manual

Bosch RF940E Series User manual

Bosch

Bosch RF940E Series User manual

Bosch Truvo User manual

Bosch

Bosch Truvo User manual

Bosch D-tect 120 Professional User manual

Bosch

Bosch D-tect 120 Professional User manual

Bosch ISW-ZPR1-WP13 User manual

Bosch

Bosch ISW-ZPR1-WP13 User manual

Bosch TriTech DS970 Series User manual

Bosch

Bosch TriTech DS970 Series User manual

Bosch LTC 2210 Series User manual

Bosch

Bosch LTC 2210 Series User manual

Bosch FCP-O 500 User manual

Bosch

Bosch FCP-O 500 User manual

Bosch RF940E Operation and maintenance manual

Bosch

Bosch RF940E Operation and maintenance manual

Bosch D-tect 150 User manual

Bosch

Bosch D-tect 150 User manual

Popular Security Sensor manuals by other brands

Roland R4000 manual

Roland

Roland R4000 manual

KJB PRO-10G user manual

KJB

KJB PRO-10G user manual

TriBrer AFD600 user guide

TriBrer

TriBrer AFD600 user guide

CCI Controls 7770 operating instructions

CCI Controls

CCI Controls 7770 operating instructions

Sercomm SZ-PIR04N installation guide

Sercomm

Sercomm SZ-PIR04N installation guide

Leuze electronic MLC 300 Series manual

Leuze electronic

Leuze electronic MLC 300 Series manual

eufy Security Smart Buoy user manual

eufy Security

eufy Security Smart Buoy user manual

Visonic SRN-2000 SERIES installation instructions

Visonic

Visonic SRN-2000 SERIES installation instructions

Winland Vehicle Alert Installation and operation instructions

Winland

Winland Vehicle Alert Installation and operation instructions

Visonic NEXT PLUS Series installation instructions

Visonic

Visonic NEXT PLUS Series installation instructions

Saso PA-0112 installation instructions

Saso

Saso PA-0112 installation instructions

NDT EVOTIS Operation manual

NDT

NDT EVOTIS Operation manual

PCB Piezotronics ICP W105C12/003AG030FW Installation and operating manual

PCB Piezotronics

PCB Piezotronics ICP W105C12/003AG030FW Installation and operating manual

BEA LZR-FLATSCAN SW quick guide

BEA

BEA LZR-FLATSCAN SW quick guide

PCB Piezotronics TORKDISC 5302D-02A Installation and operating manual

PCB Piezotronics

PCB Piezotronics TORKDISC 5302D-02A Installation and operating manual

Micropack FDS300 installation guide

Micropack

Micropack FDS300 installation guide

SMT monilog quick guide

SMT

SMT monilog quick guide

Elko iNels RFMD-100 quick start guide

Elko

Elko iNels RFMD-100 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.