TriTech Motion Detector
ISC-CDL1-W15H, ISC-CDL1-W15K
© 2015 Bosch Security Systems, Inc. F.01U.304.624 | 05 | 2015.06
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, NY 14450
USA
www.boschsecurity.com
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany
Voltage (operating) 9 to 15 VDC, 9-15 V
9-15 Vcc
de 10 à 15 mA @ 12 Vcc en veille/en alarme, source limitée en
puissance, ondulation résiduelle 1 V.
Current (max) <35 mA
Alarm relay /Tamper <100 mA, 25 V , 2.5W
Wiring loops Ø 1.29 mm to 0.40 mm
(16 AWG to 26 AWG)
Operating temperature -30°C to +55°C (-22°F to +130°F)
UL 0°C to +49°C (+32°F to +120°F)
AFNOR/CNPP -10°C to +55°C
Relative humidity 95% non-condensing
UL and C-UL 93%
0 m 2 m 4 m 6 m 8 m 10 m
15 m
0 ft 7 ft 13 ft 20 ft 26 ft 33 ft
50 ft
0 m
7.5 m
6 m
4 m
2 m
0 m
2 m
4 m
6 m
7.5 m
0 ft
25 ft
20 ft
13 ft
7 ft
0 ft
7 ft
13 ft
20 ft
25 ft
≥2.3 m ≥7.5 ft
≤2.75 m ≤9 ft
12 m
39 ft
14 m
46 ft
90°
Changes or modifications not expressly
approved by Bosch Security Systems, Inc.
can void the user’s authority to operate the
equipment.
FCC/IC
This device complies with part 15 of the
FCC Rules and Industry Canada licence-
exempt RSS standard(s). Operation is
subject to the following two conditions:
(1) this device may not cause interference,
and
(2) this device must accept any
interference, including interference that may
cause undesired operation of the device.
Optional Brackets: B328, B338, B335
A mounting bracket can reduce the
detector’s range and create dead zones. Not
investigated by UL. Not EN50131 compliant.
La certificazione IMQ decade nel caso di
installazione del rilevatore con gli snodi
opzionali.
Microwave:
If necessary, adjust microwave range slightly
until required coverage is met.
Au besoin, ajuster légèrement la portée
hyperfréquence jusqu’à atteindre le champ de
détection souhaité.
This product is intended for use in
the following countries within the European
Union and in other countries outside the
European Union:
ISC-CDL1-W15G (10.525 GHz): United
States, Canada, Austria, Belgium, Denmark,
Finland, Greece, Italy, Luxembourg,
Netherlands, Norway, Portugal, Spain,
Sweden.
ISC-CDL1-W15H (10.588 GHz): France,
United Kingdom
ISC-CDL1-W15K (9.35 GHz): Germany
SELV
Connect all wiring to a safety extra-low
voltage (SELV) circuit only.
Ligue todas as cablagens apenas a um
circuito de segurança de tensão extra baixa.
Conecte el cableado únicamente a un circuito
de seguridad para voltajes muy bajos.
Sluit alle bedrading uitsluitend aan op een
circuit met een extra lage veiligheidsspanning.
Prenez soin de connecter tous les câbles à
un circuit à très basse tension de sécurité
(TBTS).
Collegare tutti i cavi esclusivamente a un
circuito di sicurezza a bassissima tensione).
UL/C-UL
Use only a Listed Class 2 Power Limited
power source.
Standby power: The Listed control unit or a
Listed burglary power supply must provide 4
hours of standby power.
Install the unit in accordance with National
Electrical Code NFPA 70 and Part 1 of the
Canadian Electrical code CSA C22.1.
Models ISC-CDL1-W15H & ISC-CDL1-W15K
are not UL or C-UL Listed.
Under Industry Canada regulations, this
radio transmitter may only operate using
an antenna of a type and maximum (or
lesser) gain approved for the transmitter by
Industry Canada.
Conformément à la réglementation
d’Industrie Canada, le présent émetteur
radio peut fonctionner avec une antenne
d’un type et d’un gain maximal (ou inférieur)
approuvé pour l’émetteur par Industrie
Canada.
Dans le but de réduire les risques de
brouillage radioélectrique à l’intention
des autres utilisateurs, il faut choisir le
type d’antenne et son gain de sorte que la
puissance isotrope rayonnée équivalente
(p.i.r.e.) ne dépasse pas l’intensité
nécessaire à l’établissement d’une
communication satisfaisante.
Le présent appareil est conforme aux CNR
d’Industrie Canada applicables aux appareils
radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes :
Se necessario, regolare leggermente il
range delle microonde fi no a raggiungere la
copertura richiesta.
(1) l’appareil ne doit pas produire de
brouillage, et
(2) l’utilisateur de l’appareil doit accepter
tout brouillage radioélectrique subi,
même si le brouillage est susceptible d’en
compromettre le fonctionnement.
To reduce potential radio interference to
other users, the antenna type and its gain
should be so chosen that the equivalent
isotropically radiated power (e.i.r.p.) is not
more than that necessary for successful
communication.
Test yearly
Bosch Security Systems, Inc. | 2
1
6 |
12
5 |
4 |
2
3 |
=
B328
B338
B335
1
2
2 |
1 |
2,3 m - 2,75 m
(7.5 ft - 9 ft)
Bosch Security Systems, Inc. | 3
HI
LO
1 2
ON
1 2
ON
LED
PIR
EN Grade 2
9 | 10.1 |
2 min
2 s 2 s
1
3
2
7.3 |7.2 |
7.1 |
7.4 | 8 |
1
2
2.2 k
1.0 k
2.2 k
33 k
1.0 k
NC NC
T
T
NC NC T
T
12
9 to 15 VDC
1
2
2.2 k
1.0 k
2.2 k
33 k
1.0 k
1
2
2.2 k
1.0 k
2.2 k
33 k
1.0 k
1
2
2.2 k
1.0 k
2.2 k
33 k
1.0 k
NC NC T
T
1
2
2.2 k
1.0 k
2.2 k
33 k
1.0 k
1
2
2.2 k
1.0 k
2.2 k
33 k
1.0 k
NC NC T
T
9 to 15 VDC
NC
NC
T
T
2
9 to 15 VDC
NC NC
T
T
12
NC NC T
T
1
2
2.2 k
1.0 k
2.2 k
33 k
1.0 k
9 to 15 VDC
Bosch Security Systems, Inc. F.01U.304.624 | 05 | 2015.06 | 4
Copyright
This document is the intellectual property of Bosch Security Systems, Inc., and is protected
by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document are likely to be registered
trademarks and must be treated accordingly.
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to the
Bosch Security Systems, Inc. website at http://www.boschsecurity.com/datecodes/.
Region Agency Certification
US FCC FCC Part 15 Class B
UL -W15G: Intrusion Detection Unit Type: S
Canada CUL -W15G: Intrusion Detection Unit Type: S
IC Model ISC-CDL1-W15G 1249A-CDL1
Europe EN Standards EN 50131-2-4
EN 50130-5
Environmental Class II,
Grade 2 / IP41 / IK04 (EN60529, EN 62262)
France AFNOR/
CNPP/NFA2P
ISC-CDL1-W15G Cert # 2800200015
NF&A2P Grade 2
ISC-CDL1-W15H Cert # 2820200013
RTC 50131-2-4
NF-324-H58 – 110P2
AFNOR Certification: www.afnor.org
CNPP Cert.: www.cnpp.com
Sécurité contre la fraude: Autosurveillance à l’ouverture et à
l’arrachement, Immunité champ magnétique.
Germany VdS VdS Gxxxxxx
Class B
2110EN Enviromental Class 2
EN50131-2-4 + VdS2312en : Grade 2 ISC-CDL1-W15K
Australia ACMA RCM
Italy IMQ Certificato IMQ sistemi di sicurezza 3° livello di prestazione
secondo CEI79-2:1998 + Ab:2000 (modello W15G)
Sweden SBSC For svensk installationsanvisning se www.boschsecurity.se
ON
1 2
10.2 |
1
2
MIN MAX
10.3 |
2 min
2 s 2 s
1
3
2

This manual suits for next models

1

Other Bosch Security Sensor manuals

Bosch Analog Detector Series Operating instructions

Bosch

Bosch Analog Detector Series Operating instructions

Bosch DS778 User manual

Bosch

Bosch DS778 User manual

Bosch Anatel Professional Series User manual

Bosch

Bosch Anatel Professional Series User manual

Bosch WEU PDO Multi User manual

Bosch

Bosch WEU PDO Multi User manual

Bosch ISC-SM-90 User manual

Bosch

Bosch ISC-SM-90 User manual

Bosch CRS-WM-TA869 User manual

Bosch

Bosch CRS-WM-TA869 User manual

Bosch FCP-O 500 User manual

Bosch

Bosch FCP-O 500 User manual

Bosch 200 C User manual

Bosch

Bosch 200 C User manual

Bosch TriTech DS950 Series User manual

Bosch

Bosch TriTech DS950 Series User manual

Bosch 440 Series User manual

Bosch

Bosch 440 Series User manual

Bosch Blue Line Q1 User manual

Bosch

Bosch Blue Line Q1 User manual

Bosch ISC-PPR1-WA16G User manual

Bosch

Bosch ISC-PPR1-WA16G User manual

Bosch Multi-Detector DMD4 Assembly instructions

Bosch

Bosch Multi-Detector DMD4 Assembly instructions

Bosch DS 935 LSN User manual

Bosch

Bosch DS 935 LSN User manual

Bosch DS938Z Series User manual

Bosch

Bosch DS938Z Series User manual

Bosch DS432i-CHI User manual

Bosch

Bosch DS432i-CHI User manual

Bosch ISC-BDL2-WP12 User manual

Bosch

Bosch ISC-BDL2-WP12 User manual

Bosch BMA400 Instruction Manual

Bosch

Bosch BMA400 Instruction Manual

Bosch Blue Line P1 User manual

Bosch

Bosch Blue Line P1 User manual

Bosch Blue Line D1-P User manual

Bosch

Bosch Blue Line D1-P User manual

Bosch PROFESSIONAL wallSCANNER D-TECT 100 concrete User manual

Bosch

Bosch PROFESSIONAL wallSCANNER D-TECT 100 concrete User manual

Bosch D-tect 150 Professional User manual

Bosch

Bosch D-tect 150 Professional User manual

Bosch ISC-PDL1-W18H User manual

Bosch

Bosch ISC-PDL1-W18H User manual

Bosch Photobeam 5000 Operating instructions

Bosch

Bosch Photobeam 5000 Operating instructions

Popular Security Sensor manuals by other brands

Aling Conel 72203 installation manual

Aling Conel

Aling Conel 72203 installation manual

NEW TRIBE AERO HUNTER User instructions

NEW TRIBE

NEW TRIBE AERO HUNTER User instructions

jablotron JA-83P manual

jablotron

jablotron JA-83P manual

VOLTCRAFT LSG-10 operating instructions

VOLTCRAFT

VOLTCRAFT LSG-10 operating instructions

Honeywell Home PROSiXPANIC Quick installation guide

Honeywell Home

Honeywell Home PROSiXPANIC Quick installation guide

NAPCO GEMC-WL-CO installation instructions

NAPCO

NAPCO GEMC-WL-CO installation instructions

Preiffer adixen ASM 380 operating instructions

Preiffer

Preiffer adixen ASM 380 operating instructions

Vulkan Lokring LOKATOR VL30 instruction manual

Vulkan

Vulkan Lokring LOKATOR VL30 instruction manual

RIDGID NaviTrack Battery Sonde instructions

RIDGID

RIDGID NaviTrack Battery Sonde instructions

EMX Industries CarSense202 CS202 instruction manual

EMX Industries

EMX Industries CarSense202 CS202 instruction manual

Siemens Sinteso FD20 Guideline

Siemens

Siemens Sinteso FD20 Guideline

ETC echoflex MOS-IR A Series installation guide

ETC

ETC echoflex MOS-IR A Series installation guide

GJD D-TECT Universal GJD630 manual

GJD

GJD D-TECT Universal GJD630 manual

Teletek electronics SensoMAG R20 Installation instruction

Teletek electronics

Teletek electronics SensoMAG R20 Installation instruction

DELTA DORE Tyxal+ DME 180 manual

DELTA DORE

DELTA DORE Tyxal+ DME 180 manual

Teracom TSM400-1-CP user manual

Teracom

Teracom TSM400-1-CP user manual

Niko SG360KNX/KLR RA 16 m instruction manual

Niko

Niko SG360KNX/KLR RA 16 m instruction manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.