Cap Press Two in One Manual
brildor.com
V.
Maintenance
1. No action after turn on the machine
1). Check the plug whether it connects well or whether it is broken.
2). Check the power switch or digital controller whether it is broken.
3). Check the fuse whether it has been burnt out.
4). Indicating light is on, but no display on screen, check the 5 cable of Railway transformer. If it’s loosening,
showing the problem is poor connection. If they connects well, showing that the Transformer is faulty.
2. The display screen are working well, but no temperature increasing on the heating element.
1). Check whether the thermocouple of the heating element touches well. If the thermocouple is loose, the display
will show 255℃. and machine keeps beeping.
2). Check if the indicating light of solid-state relay is on, if not, check if the relay or digital controller is broken.
3). If you already changed the new solid-state relay but the heating element still can’t heating up, check if the cap
heater is faulty or the heating element’s power cable is loose, need to change by new heating element.
3. The display screen show 255℃once you power on.
1). Check whether the thermocouple is loose or not.
2). If the thermocouple touches is not in loose state, but still show 255℃, then it is faulty.
4. The machine is heating during 0~180
, but display number jumps to above 200
or 300
suddenly, or
the numbers on display jumps irregularly.
1). Check whether the thermocouple of the heating element touches well.
2). If the thermocouple is good, It shows that the program of digital controller is broken, which namely IC or is
broken, need to change by new controller.
5. The temperature is out of control: Set 180℃,but the actual temperature is above 200℃。
1). It means the solid-state relay is broken, out of control, need to change the relay.
2). Or the digital controller is faulty and it keeps conveying electric to relay, need to change controller.
6. The setting temp and time becomes abnormal after exchange the heating element.
1). Please reset the temp and time according the operation process manual.
7. Other notice
1). In order to prolong the machine service life, please add the lubrication oil regularly on the joints.
2). In order to keep the cap heater's good transfer effect, pls protect it carefully whenever you are using or not.
3). Please keep the machine in dry place.
4). If you are not able to solve the electrical parts problem, please kindly contact the supplier and get technical
support.
VI.
Trouble shooting for transfer print quality
1. If the print color is pale: the temperature is too low / the pressure is not correct / or not pressed long enough.
2. If the print color is too brown or the transfer paper is almost burnt: reduce the setting temperature.
2. If the print is blurring: too much transfer time causes proliferation.
3. If print color is different/ partial transfer effect is not good enough: the pressure is not enough / or not pressed
long enough / or poor quality transfer paper.
4. If transfer paper stick to the object after transfer: the temperature is too high/ or poor quality printing ink.