Troubleshooting
Notes
Symptom Cause Remedy
No flow or
low flow
rate
Partially closed isolation valve. Open isolation valve.
Instantaneous water heater cycles on
and o as flow rate or pressure is too
low.
Increase water flow rate or pressure through system.
Head of water is below the
minimum distance required.
Refer to specification for minimum distance required.
Hot or cold water being drawn o
elsewhere causing pressure changes or
instantaneous boiler temperature
changes.
Do not use other water outlets when using the taps.
Airlock or partial blockage in the supply
pipework.
Flush through pipework to ensure removal of debris
and any airlocks.
Water
dripping
from taps
This is normal for a short time after using
the taps.
This is caused by residual water tension, the build up
of water in the tap body.
If water continues to drip,
possibly due to the ceramic disc valves
Remove valves and clean, refer to 'Maintenance'
section before starting any maintenance.
Taps do not
turn on
Closed isolation valve. Open isolation valve.
Mains water supply turned o. Turn on mains water supply.
123
Please use this space for any notes you or your installer may have regarding the
installation/plumbing of this product.
Installation - Wall Bracket
Check handset sits securely on the
wall bracket and there is no movement
3
2
1
Maintenance - Cleaning/Replacing Valves
Remove the
valves.
Place valves in a suitable
solution and soak until
fully de-scaled.
4Reverse the
maintenance
steps to replace
the handles.
12
3
You may need to use
adjustable spanner
Bristan products are made from premium materials,
with hand polishing and
electroplated finishes.
Your taps or shower should be regularly cleaned
with warm water, a mild pH-neutral liquid soap, and
polished with a soft cloth. Any residues from soap,
toothpaste,
shampoos and shower gels can cause blemishes if
not rinsed o straight after use.
Household bleaches and cleaners contain harsh
chemicals and may damage the surface finish. Avoid
using abrasive cloths, scouring pads, scrub sponges,
steel wool
or anything similar.
Some surfaces such as nickel and pewter may be af-
fected by the dye found in some cloths, so it is also
important to avoid
hanging cloths on spouts.
General Cleaning
Cold
Hot
On
On
Push diverter
down for
Bath Fill
Pull up
diverter for
Handset
At Bristan, we want to make things as easy as possible for our customers. That’s why we oer
solid guarantees on all our products, eective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product.
Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where our expert team
of advisors will be able to oer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/service-centre/guarantees.
Position the wall
bracket where you
want it and mark out
where to drill.
Drill holes where marked and fit
rawl plugs. Secure wall bracket to
wall using screws provided.
IMPORTANT
Prior to drilling
into walls check
there are
no hidden electrical
wires, cables or
water supply
pipes
Unscrew gently to remove
the outlet with adjustable
spanner.
Check for damage. Soak
using a suitable solution
to de-scale.
Screw back into the tap body
to replace the outlet.
Maintenance - Outlet Cleaning
IMPORTANT
Isolate the
water supply
before
starting!
Remove indice and grub
screw to pull o handle.
Undo screw and remove
spline adaptor.
IMPORTANT
Isolate
the water
supply before
starting!
Operation