BRK electronic SC9120B User manual

CAT. SC9120B
10YR CO SENSOR
10YR ALARM LIFE
SMOKE & CO COMBO
Electrochemical CO sensor; Ionization
smoke sensor.
LATCHING ALARM
INDICATOR
Remembers which unit initiated an alarm.
SILENCE FEATURE
Silences nuisance alarms.
END OF LIFE SIGNAL
Provides audible notice when alarm
needs to be replaced after 10 years.
Description:
The BRK Brands, Inc. model SC9120B is a wire-in, 120V AC 60Hz single and/
or multiple station smoke and CO alarm specifically designed for residential and
institutional applications including sleeping rooms of hospitals, hotels, motels, dor-
mitories and other multi-family dwellings as defined in standard NFPA 101. The
SC9120B complies with UL217, UL2034, CSFM, NFPA 72, NFPA 720, HUD, FHA
and other agencies that model their codes after the above agencies. They meet
building codes where AC/DC with Silence smoke and CO alarms are required ei-
ther separately or in combination. The alarms are interconnectable with up to 18
devices, of which 12 can be smoke alarms.
The BRK®SC9120B alarm features a dual ionization smoke sensing chamber and
an electrochemical carbon monoxide sensor, an 85dB horn and a “silence” feature.
“Intelligent Sensing Technology” system is designed to reduce nuisance alarms.
“Latching Alarm Indication” remembers which unit initiated an alarm. When in-
terconnected in a series, the unit that triggered the alarm rapidly flashes its red
LED indicator. After the alarm condition subsides, the initiating unit will store in
memory or “latch” the information and begin to flash the LED indicator 2 seconds
on, 2 seconds off. The “Perfect Mount” system features a gasketless base and a
mounting bracket that keeps the alarm secure over a wide rotation range to al-
low for true alignment. Other Contractor Preferred features include a dust cover
to keep alarm clean during construction, keyhole slots in the mounting bracket
eliminate the need to remove the electrical box screws for installation. Two locking
features are provided to prevent battery theft and/or theft of the unit. Connection
to AC power is made with a “Quick-Connect” wiring harness. Installation is quick,
easy and cost effective.
120V AC, 60Hz Wire-in
with 9V Battery Backup
SMOKE & CO
COMBO
ALARM
CAT. SC9120B
ARCHITECTURAL AND ENGINEERING SPEC
TECHNICAL SPECS
SHIPPING SPECS
INSTALLATION OF ALARM
The combination smoke and CO alarm shall be a BRK Model SC9120B and shall provide at
a minimum the following features and functions:
1. An ionization smoke sensing chamber and an electrochemical CO sensor both with a
10 year service life.
2. Powered by 120V AC, 60Hz and have a monitored 9V battery backup and a solid state
piezo horn rated at 85dB at 10 ft. and be capable of self restoring.
3. The unit shall perform self diagnostic tests and issue a malfunction warning (three
chirps) if the unit malfunctions.
4. The unit shall have an “End of Life” signal (5 chirps). This signal should be capable of
temporarily being silenced for up to 2 days. After about 2 days, the signal will resume.
After about 2-3 weeks the signal cannot be silenced.
5. A visual power-on indicator to confirm unit is receiving AC power or has switched to
battery backup mode. Separate LED ‘s to indicate a smoke or CO alarm.
6. The CO sensor is adjusted not to detect CO levels below 30 PPM and will not alarm
when exposed to constant levels of 30 PPM for 30 days. It will alarm at the following
levels: 400 PPM CO between 4 and 15 minutes, 150 PPM CO between 10 and 50
minutes and 70 PPM CO between 60 and 240 minutes.
7. Two Latching features: Alarm Latch to easily identify initiating alarm after alarm
condition has subsided. Low battery latch: to visually identify which unit is in low
battery condition. Two Silence Features: Alarm Silence to temporarily silence nuisance
alarms. Low Battery Silence to silence low battery chirp for up to 8 hours.
8. Two Locking features - tamper resistant locking pins that lock battery drawer
and/or alarm to mounting bracket.
9. The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and
relative humidity between 10% and 95%.
10. The unit shall have a plug in connector and be capable of interconnection of up to 18
alarms, 12 of which can be smoke alarms.
11. The unit shall at a minimum meet the requirements of UL217 and UL2034, CSFM,
NFPA 72 and 720 and the ICC.
Alarm Dimensions: 5.6”dia. x 2.0”H
Weight: 8.5 oz
Operating Voltage: 120V AC 60Hz w/ 9V alkaine battery backup
Operating Current: 0.09 amps (standby/alarm)
Temperature Range: 40°F (4°C) to 100°F (38°C)
Humidity Range: 10% to 95% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Test/Silence: Electronically simulates smoke or CO condition, causing the
unit to alarm. Press and hold test/silence button.
Alarm Reset: Automatic when smoke or CO clears
Interconnections: Up to 18 units of First Alert or BRK Smoke, CO and Heat
Alarms. Maximum of 12 smoke alarms. See user’s manual
for details.
Smoke Sensor: Dual Ionization
CO Sensor: Electrochemical
Indicator Lights/Sounds:
AC Power: Constant Green LED
DC Power: Intermittent Green LED
Local Alarm: Red LED flashes rapidly
Remote Alarm: Red LED out.
Latching Alarm: Red LED flashes 2 sec. on/2 sec. off after local alarm
Low Battery Latch: Green LED flashes on for 2 seconds, off for 2 seconds.
Listing: Listed to UL217 and UL2034 Standards
Individual Carton Dimensions 5.69”L x 2.25”W x 5.59”H
Weight 0.63 lbs.
Cube 0.04 ft3
UPC 0 29054 51306 9
Master Carton Dimensions 14.43”L x 6.19”W x 12.63”H
Master Pack 12
Weight 8.1 lbs.
Cube: 0.65 ft3
I2of5: 100 29054 51306 6
Pallet Information
Cases per Layer 19
Number of Layers: 3
Cases per Pallet: 57
Units per Pallet: 684
Cube: 42.2 ft3
Weight: 527 lbs.
©2015 BRK Brands, Inc. a Jarden Corporation
Company (NYSE: JAH)
3901 Liberty Street Road
Aurora, IL 60504-8122
All rights reserved
First Alert is a registered trademark of the First Alert Trust
BRK is a registered trademark of BRK Brands, Inc.
CM3233
brkelectronics.com
Installation of this smoke alarm must conform to all local electrical
codes and Article 760 of the National Electrical Code (NFPA 70) and
NFPA 72. Interconnected units must meet the following requirements:
Total length of wire interconnecting units should be less than 1000 feet,
be #18 gauge or larger and be rated at least 300V. It is recommended
that all units be on the same fuse or circuit breaker. If local codes
do not permit, be sure the neutral wire is common to both phases.
THE PARTS OF THIS SMOKE ALARM
1. Mounting bracket
2. Mounting Slots
3. Locking Pins
4. Hot (Black) AC Wire
5. Nuetral (White) AC Wire
6. Interconnect (Orange) Wire
7. Battery Drawer Latch
8. Battery Drawer - Install 9V
battery here
9. Quick-Connect Plug
MOUNTING
BRACKET
TOP VIEW SIDE VIEW
5.6”
2.0”
1
2
3
5
6
4
2
3
9
7
8
678
43 1
5 2
A
B
}}
43 15
1. Smoke /CO Alarm
2. Ceiling or Wall
3. Power Connector
4. Wire Nut
5. Junction Box
6. Neutral Wire (White)
7. Interconnect Wire (Orange)
8. Hot Wire (Black)
A. Unswitched 120VAC 60 Hz source
B. To additional units; Maximum = 18 total
(Maximum 12 Smoke Alarms)

Other BRK electronic Smoke Alarm manuals

BRK electronic 7030BSL User manual

BRK electronic

BRK electronic 7030BSL User manual

BRK electronic PRC700VB User manual

BRK electronic

BRK electronic PRC700VB User manual

BRK electronic 9120LBLA User manual

BRK electronic

BRK electronic 9120LBLA User manual

BRK electronic SA520B User manual

BRK electronic

BRK electronic SA520B User manual

BRK electronic SL177 User manual

BRK electronic

BRK electronic SL177 User manual

BRK electronic 83RN User manual

BRK electronic

BRK electronic 83RN User manual

BRK electronic FG250 User manual

BRK electronic

BRK electronic FG250 User manual

BRK electronic 7010BSL User manual

BRK electronic

BRK electronic 7010BSL User manual

BRK electronic 4010YR User manual

BRK electronic

BRK electronic 4010YR User manual

BRK electronic SCO2B User manual

BRK electronic

BRK electronic SCO2B User manual

BRK electronic PC910B User manual

BRK electronic

BRK electronic PC910B User manual

BRK electronic 83RN User manual

BRK electronic

BRK electronic 83RN User manual

BRK electronic SC7010B User manual

BRK electronic

BRK electronic SC7010B User manual

BRK electronic 9120 Series User manual

BRK electronic

BRK electronic 9120 Series User manual

BRK electronic 7010BA User manual

BRK electronic

BRK electronic 7010BA User manual

BRK electronic SC7010BV User manual

BRK electronic

BRK electronic SC7010BV User manual

BRK electronic First Alert P1010 User manual

BRK electronic

BRK electronic First Alert P1010 User manual

BRK electronic Smoke Alarms User manual

BRK electronic

BRK electronic Smoke Alarms User manual

BRK electronic SA350B User manual

BRK electronic

BRK electronic SA350B User manual

BRK electronic 650M User manual

BRK electronic

BRK electronic 650M User manual

BRK electronic 4120 AC User manual

BRK electronic

BRK electronic 4120 AC User manual

BRK electronic 5919/5919 TH User manual

BRK electronic

BRK electronic 5919/5919 TH User manual

BRK electronic 83R-UK User manual

BRK electronic

BRK electronic 83R-UK User manual

BRK electronic HD6135FB User manual

BRK electronic

BRK electronic HD6135FB User manual

Popular Smoke Alarm manuals by other brands

ELRO FC400211 instruction manual

ELRO

ELRO FC400211 instruction manual

Ei Electronics Ei160e Series instruction manual

Ei Electronics

Ei Electronics Ei160e Series instruction manual

Longsin LS-828-27 manual

Longsin

Longsin LS-828-27 manual

LOXONE 100142 manual

LOXONE

LOXONE 100142 manual

Elektrotechnik Schabus GX-D500P operating instructions

Elektrotechnik Schabus

Elektrotechnik Schabus GX-D500P operating instructions

ADEMCO 5707 installation instructions

ADEMCO

ADEMCO 5707 installation instructions

S&S Northern Merlin FAB-1 user guide

S&S Northern

S&S Northern Merlin FAB-1 user guide

Smoky Mountain 3495GLA Assembly and owner's manual

Smoky Mountain

Smoky Mountain 3495GLA Assembly and owner's manual

Lexing LX-SO-98A-D user manual

Lexing

Lexing LX-SO-98A-D user manual

Fire Fighting Enterprises FIRERAY 2000 EExd installation guide

Fire Fighting Enterprises

Fire Fighting Enterprises FIRERAY 2000 EExd installation guide

Honeywell V-PLEX 5192SD manual

Honeywell

Honeywell V-PLEX 5192SD manual

Kidde I12020 Specifications

Kidde

Kidde I12020 Specifications

Vision ZS 6101 IN Installation & operation manual

Vision

Vision ZS 6101 IN Installation & operation manual

Kidde 910 user guide

Kidde

Kidde 910 user guide

Simplex MINIPLEX 4100-9600 manual

Simplex

Simplex MINIPLEX 4100-9600 manual

Emos P56501 manual

Emos

Emos P56501 manual

Tanda TX7100 Installation and operation manual

Tanda

Tanda TX7100 Installation and operation manual

Kyla KSEN-231 Easy start guide

Kyla

Kyla KSEN-231 Easy start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.