Bticino D45 User manual

1
322031
45
A (mm) B (mm) C (mm)
125 325 63
7
6
1
2
3
3
A C
B
D45 System
Description
20 Pushbuttons colour video entrance panel
D45 System entrance panel (EP) with colour camera and 20 backlighted call pushbuttons
with possibility to direct call to the porter switchboard.
Possibility to send an alarm message to the switchboard when opening over 2 minutes
of the associated lock or when trying to remove the device.
Setup key functions via programming, physical configurators insertion or through
the dedicated software supplied with the product. Flush mounting installation with
dedicated box (supplied with the product).
Related items
322033 additional 32 pushbuttons panel
Technical data
Power supply: 30 Vdc
Stand by absorption: ≤ 14 mA @ 30 V
Max. operating absorption: ≤ 230 mA @ 30 V
Camera sensor: 1/3”
Camera resolution: 540 TV lines (horizontal)
Lens: F3.6 mm
Illumination of the viewing field: white LEDs
Operating temperature: (-25) – (+55) °C
Protection index: IP54
Protection index against mechanical impact: IK07
Dimensional data Legend
1. LEDs for night lighting of the shooting field
2. Light sensor for automatic switching on of the night backlighting
3. Call pushbuttons (n° 20)
4. Microphone
5. Nameplates (n° 20)
6. Loudspeaker
7. Colour camera
Front view
BT00766-a-EN 03/06/2013
2
322031
11
14
13
9
8 4
7
6
5
3
2
1
10
12
N
#I
N
#I F F I I
20 Pushbuttons colour video entrance panel
Rear view
Legend
1. Switch (ON - OFF) - enable/disable anti removal (tamper) function
2. SPK : loudspeaker volume adjust
3. MIC : microphone volume adjust
4. Status jumper socket
5. RJ45 system BUS connector
6. 4 poles connector (GND /DAS/LOCK-/LOCK+). GND/DAS = electrical door lock status
connector - LOCK-/LOCK+ = electrical door lock connector
7. RJ45 additional pushbuttons panel connector
8. Mode jumper socket
9. ISP : entrance panel software upgrade connector
10.Room number reset/door lock status setting pushbutton
11.Configurations socket
12.DIP-SWITCH for video gain setting - see specific section
13.Anti-thief switch
14. VIDEO-IN/GND/NC/+12V/LED : entrance panel camera and compensation lamp
connector
Two different configuration ways available:
Configuration by inserting phisical configurators - WAY 1
Configuration by using SF2 software and PC connection - WAY 2
Entrance panel have two status, one is work status, another is setting status.
In work status, entrance panel can call internal unit and work with internal unit. En-
trance panel usually is in this status.
In setting status, entrance panel can’t call and work with internal unit,but can set room
number or SCS address of corresponding pushbutton.
After finished set, exit setting status by jumper insertion (NA).
By inserting jumper (NA), entrance panel is in work status. By inserting jumper (CF),
entrance panel is in setting status.
Call mode
D45 system have two call modalities, one is room number mode, another is SCS ad-
dress mode (direct call mode). In room number mode, internal unit can be set according
to the room number; visitor type room number in entrance panel to call resident.
Factory default is in room number mode.
In SCS address mode (direct call mode),internal unit can be set according to SCS address.
Visitor just type SCS address to call resident, for example just type 1.
For pushbuttons entrance panel, must be defined each pushbutton math a room num-
ber or SCS address.
Configuration define in setting status as for below table:
Configuration define in work status as for below table:
ROOM NUMBER MODE SCS ADDRESS MODE
#I#I maximum apartment quantity per oor Don’t use
FF oor number of corresponding pushbutton SCS address high digit of corresponding
pushbutton
II apartment number corresponding
pushbutton
SCS address low digit of corresponding
pushbutton
DEFINE
NN Entrance panel number
FF Don’t use
II Don’t use
Entrance panel status setting
Configuration
BT00766-a-EN 03/06/2013
3
322031
→504
→502
→404
→402
→304
→302
→204
→202
→104
→102
503 ←
501 ←
403 ←
401 ←
303 ←
301 ←
203 ←
201 ←
103 ←
101 ←
SCS RM CF NA
SCS RM CF NA
SCS RM CF NA
20 Pushbuttons colour video entrance panel
Configuration
Configuration settings by inserting physical resistor configuration - WAY 1:
Factory default is room number, see pushbutton corresponding room number as follows:
BT00766-a-EN 03/06/2013
Setting of entrance panel number :
Jumper select (NA) enter work status - insering the jumper between (NA pins), NN con-
figurators indicates the entrance panel number (range from 01 to 80).
Example - set the entrance panel number as 03:
while entrance panel power supply is OFF, insert a jumper between NA pins, put con-
figurators 03 in NN sockets.Then put power supply ON, the entrance panel will save the
03 number.
NOTE (A) : phisical configurator insertion has higher priority. If NO configurator inserted,
the EP number is the last value we got by configurators or by SF2 software. Default num-
ber is 01.
NOTE (B) : the entrance panel number MUST BE the same as for the associated addi-
tional pushbutton panel.
Assign room number or SCS address for each pushbutton
Room mode number
First select (CF) entering setting status, than select (RM) entering room number mode,
insert configurators, last press the pushbutton which you want to set in the front of the
panel until a long tone be heard. A long tone will indicates that room number has been
successfully completed.
Repeat configurators insertion to set all room number corresponding pushbutton.
After finished to set all room number, jumper must select (NA) to exit setting status.
Example - set the 1st. right pushbutton as 203 - number of aparments per floor = 06 :
- jumper select (CF) enter setting status, jumper select (RM) enter room number mode
- insert configurators 02 in FF sockets and configurators 03 in II sockets and insert con-
figurators 06 in #I #I
- press the 1st. pushbutton left on the front of the panel. A long tone indicates setting
well done. If you heard three short tones it means that setting is wrong. (We cannot set
FF and II as 00).
- repeat this setting sequence for all pushbuttons. At the end, insert a jumper between
(NA pins). The setting procedure is finished.
POSITION VALUE FOR CONFIGURATOR
N 0
N 6
F 0
F 2
I 0
I 3
POSITION VALUE FOR CONFIGURATOR
N
N
F 0
F 1
I 2
I 3
(SCS) - SCS address mode
(RM) - Room number mode
(CF) - Setting status
(NA) - Work status
SCS address mode (direct call mode)
First, jumper select (CF) entering setting status, than jumper select (SCS) entering SCS
address mode. Insert configurators, last press the pushbutton which you want to set in
the front of panel until a long tone be heard. A long tone will indicates SCS address has
been successfully completed.
Repeat configurators insertion to set all SCS address corresponding pushbutton.
After finished to set all SCS address, jumper must select (NA) to exit setting status.
Example - set the 1st. right pushbutton as 0123:
- jumper select (CF) enter setting status, jumper select (CF) enter SCS address mode
- insert configurators 0123 in FFII sockets
- press the 1st. pushbutton left on the front of the panel. A long tone indicates setting
well done. If you heard three short tones it means that setting is wrong. (Max. SCS
configuration address is 4000).
- repeat this setting sequence for all pushbuttons. At the end, insert a jumper between
(NA pins). The setting procedure is finished.
Setting of porter switchboard call :
same procedure as for the SCS address mode setting but porter switchboard address is
fixed to 4000. Means that FFII must be set as 4000.
4
322031
1 2
ON
OFF
ON OFF
20 Pushbuttons colour video entrance panel
Configuration
Setting of anti removal (tamper) function:
This function indicates the removal of the device from the wall. If someone try to re-
move the device from the wall, an alarm message will be sent to the porter switchboard.
On the back of the entrance panel, there are two ON - OFF switches : one is the anti
tampering function enable switch; the other is to set ON or OFF this function.
Configuration by using SF2 Software and PC connection- WAY 2 :
This is the enhanced way to download the device configuration to entrance panel previ-
ously created by using SF2 configuration software and a personal computer. To transfer
use the configuration hardware tool 323020 serial interface
WARNING : to ensure that the communication is successful, entrance panel must
be powered and NOT phisically configured.
Distance 1 2
0 –300 m OFF OFF
300 – 700 m ON OFF
700 – 1000 m ON ON
The entrance panel has two video compensation gears, we can let the video signal
output adapt to different transmission distance. See followings:
DIP SWITCH SETTINGS FOR B/W. AND COLOUR SYSTEM
Video gain setting
323020
configuration
tool
BT00766-a-EN 03/06/2013
Setting of door lock status:
device in stand by status - press and mantain for about 3 seconds the key located
on the back of the entrance panel. A short tone indicates that device detect the actual
door lock status (always ON or OFF - this status will be signalled to porter switchboard).
Reset of factory default room number for each pushbutton
device in stand by status - press and mantain for about 6 seconds the key located on
the back of the entrance panel until one long tone is heard. This indicates that the reset
has been successfully completed.
0 3 sec.
Setting
of door lock status
Reset factory default
room number for each pushbutton
6 sec.

Other manuals for D45

5

This manual suits for next models

1

Other Bticino IP Access Controllers manuals

Bticino 374000 User manual

Bticino

Bticino 374000 User manual

Bticino 374005 User manual

Bticino

Bticino 374005 User manual

Bticino IP DES User manual

Bticino

Bticino IP DES User manual

Popular IP Access Controllers manuals by other brands

Verkada ACC-MNT-11 install guide

Verkada

Verkada ACC-MNT-11 install guide

smart home MP7 quick start guide

smart home

smart home MP7 quick start guide

UNIONCOMMUNITY UBio-X Face user guide

UNIONCOMMUNITY

UNIONCOMMUNITY UBio-X Face user guide

Iron logic Matrix-IV EHT Keys Metal user manual

Iron logic

Iron logic Matrix-IV EHT Keys Metal user manual

UNIONCOMMUNITY AC-7000 user guide

UNIONCOMMUNITY

UNIONCOMMUNITY AC-7000 user guide

Entrematic AXR7 installation manual

Entrematic

Entrematic AXR7 installation manual

Paradox DB7 Quick installation

Paradox

Paradox DB7 Quick installation

EDS SK-30 installation manual

EDS

EDS SK-30 installation manual

Gianni Industries GEM DG Series manual

Gianni Industries

Gianni Industries GEM DG Series manual

Cansec Zodiac FR100 Operator's guide

Cansec

Cansec Zodiac FR100 Operator's guide

Kaba Access Manager 200 Quick setup

Kaba

Kaba Access Manager 200 Quick setup

Security Brands 16-X1 quick start guide

Security Brands

Security Brands 16-X1 quick start guide

Ascent 16-X1 Plus quick start guide

Ascent

Ascent 16-X1 Plus quick start guide

Roger PR411DR installation guide

Roger

Roger PR411DR installation guide

Feig Electronic ID MAX.U500i Series Quick installation

Feig Electronic

Feig Electronic ID MAX.U500i Series Quick installation

Roger PRT12MF-DES installation manual

Roger

Roger PRT12MF-DES installation manual

Prisma H701 user manual

Prisma

Prisma H701 user manual

Motorola SDC1000 operating manual

Motorola

Motorola SDC1000 operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.