Bullard NXT User manual

Thank you and congratulations on your purchase
of the Bullard NXT
The Bullard NXT offers numeric and bar temperature measurement as well as
automatic tri-color Super Red Hot (SRH) high heat colorization in all modes of
operation. Optionally, if so equipped, digital video recording (DVR) also operates
in all modes. Depending on your unit’s configuration, additional optional features
are available inTI BASIC PLUS mode, including ElectronicThermalThrottle®(ETT)
manual colorization and 2X / 4X digital zoom.
The benefits of using thermal imaging technology as a firefighting tool encompass
nearly every aspect of a firefighter’s job.Thermal imaging is not, however, a
technology designed to replace current firefighting tactics. Rather, it is a tool that
allows the firefighter to be more effective and make better decisions. Some of the
many uses for your Bullard NXTThermal Imager include:
• Search and rescue
• Scene assessment
• Locating the seat of the fire
• Determining the spread of the fire
• Locating hot spots
• Identifying potential flashover situations
• Determining ventilation points
• Determining entry and exit points
• Overhaul
• Hazmat
• Wildland firefighting
• Incident investigation
•Training
�WARNING
Read all instructions and warnings before using this product.
Your thermal imager is like any other tool. It must be used properly and safely.
All users should be trained on the proper and safe use of thermal imaging
prior to using the Bullard NXTThermal Imager. This is especially important
for users who may use this product in hazardous or IDLH (Immediately
Dangerous to Life and Health) environments.
FAILURE TO FOLLOW THIS INFORMATION COULD RESULT IN DEATH OR
SERIOUS INJURY.
www.bullard.com
Bullard NXT Thermal Imager
User Manual
Overview of the Bullard NXT
Display window
POWER button/ ON indicator and LED
indicator (ExitsTI BASIC PLUS mode)
RIGHT button
(controls DVR and ETT)
(ETT inTI BASIC PLUS Mode)
(DVR in all modes)
Front Plate
Germanium Lens
Digital Zoom: LEFT and RIGHT
Buttons (long press)
(TI BASIC PLUS Mode)
TI BASIC PLUS Mode:
long-press LEFT button
LEFT button
(controls ETT)
(TI BASIC PLUS Mode)

www.bullard.com
2
General Operation
To turn ON your Bullard NXT, depress the green power button located on top of the
unit.The screen will display the Bullard NXT logo and the green power button will
illuminate. A thermal image will appear within a few seconds. This image consists
of black, white, and grey elements which indicate heat signatures of objects and
scene dynamics. Warmer elements appear as lighter shades, while cooler elements
appear as darker shades.
NOTE:
You will periodically observe a momentary freeze in the imager. This is normal
and is a function of the self-calibration
shutter.The shutter will activate several
times during the first 5 minutes,
depending on the environment.
To turn OFF your Bullard NXT, depress and hold
the power button until the “red” power icon
located in the top left of the display illuminates
and then changes from red to green. When
the icon changes from red to green, release
and the unit will power off.
System LED Indications
The power button LED will be illuminated when the imager is powered ON. In
addition, the same LED changes colors to communicate other system conditions
related to charging, as indicated below. Note that ONLY the green power indication
functions when theTI is not connected to a charging system (i.e. standalone
operation).
SOLID GREEN Imager is powered ON (not charging)
SOLID GREEN Imager is fully charged (via desktop or truck mount)
PULSING GREEN Imager is “thinking” (charge system processing)
PULSING RED Imager battery is charging (via desktop or truck mount)
FLASHING YELLOW Error condition (problem with theTI or charging system)
On-Screen Indications
TI BASIC Mode
Overview
The Bullard NXT always powers up inTI BASIC Mode. This is a simplified mode
intended to provide easy operation as well as standardization of thermal imaging
features and user interface functions as follows.
Heat Color Reference Bar
Indicates scene temperature (see Super Red Hot Colorization).
Sensitivity (Gain) Modes
The imager automatically switches between low and high sensitivity (gain) modes
based on ambient scene temperatures in order to protect the thermal sensor
from overload in high-temperature situations.The low sensitivity mode activates
in high-heat situations, and deactivates as ambient heat decreases (i.e. lower
temperatures).The low sensitivity mode indicator consists of a green triangle
located in the upper left of the viewing area.
Overheat Indicator
A visual warning flashes which indicates to the user that the thermal imager might
cease to operate due to internal overheating, as mandated by NFPA 1801 standard.
The imager’s internal electronics remain functionally useful within the range of
-20° C to 85° C.
Power Source Indicator (Battery Status Indicator)
(1)Four green segments displayed (76-100% charge)
(2)Three green segments displayed (51-75% charge)
(3)Two yellow segments displayed (26-50% charge)
(4)One red segment displayed (0-25% charge)
(5)One red segment flashing (at least 5 minutes of runtime remains)
Estimated operation time on fully charged power source in available mode.
FULL power (green) 4.5 ->6
hours
75% power (green) 3.0 - 4.5
hours
50% power (yellow) 1.5 - 3.0
hours
25% power (red) 1.5 hours
Will begin to flash when at least 5 minutes of
available power source remains (red)
> 5
minutes
NOTE:
(1) During operation the bar will deplete from left to right.
(2)
THE BULLARD NXT’S INTERNAL LITHIUM ION BATTERY PACK IS
DESIGNED FOR MAXIMUM LIFE WHEN THE BATTERY IS KEPT FULLY
CHARGED. BULLARD RECOMMENDS LEAVING THE NXT CONNECTED
TO YOUR PREFERRED CHARGING SYSTEM WHEN THE UNIT IS NOT IN
USE.
(3) Power off the imager during charging.
Temperature Bar
TheTemperature Bar is a bar-graph style temperature gauge in the right portion
of the display. The bar/numeric indicator displayed represents the approximate
temperature of the object viewed within theTemperature Measurement Zone
in the center of the display. Accuracy of indication is dependent on numerous
factors including the distance from the object being viewed (accuracy decreases
as distance increases) and its emissivity (heat radiation properties). Your Bullard
NXT is factory-calibrated to emissivity corresponding with normal construction
materials. Objects with emissivity varying greatly from this (particularly reflective
objects such as metals and shiny materials) reduces accuracy of the temperature
indication.
Detail of Power Source Indicator

www.bullard.com
Numeric Temperature Indicator
Displays next to theTemperature Bar and indicates the measured temperature of
an object in theTemperature Measurement Zone (center of the display).
NOTE:
The indicators provide a quick reference to compare objects of similar
emissivity in order to assist with identification of intense heat sources. Due to
the inherent issues with accuracy, use these features with caution and verify
indicated heat levels through traditional means whenever possible.
Super Red Hot (SRH) Colorization
The Bullard NXT utilizes easy-to-use Super Red Hot (SRH) colorization which
displays heat levels in yellow, orange, and red hues.This feature identifies specific
heat layers, thus alerting firefighters to areas of intense heat through visual
awareness of the hottest objects in a scene.The SRH feature automatically adds
colorization at temperatures above 500° F (260º C).
SRH colorization engages automatically at temperatures 500° F (260º C) or greater.
Temperatures below 500° F (260° C) remain grayscale (white hot polarity). Objects
between 500° F (260° C) and 799° F (426° C) appear yellow; objects 800° F
(427° C) to 999° F (537° C) appear orange; objects 1000° F (538° C) or hotter
appear red.The SRH overlay remains semi-transparent, allowing the scene detail
such as thermal flows to remain visible under the SRH colorization.
SRH has a Heat Color Reference Bar adjacent to the Temperature Bar. The
temperature is illustrated by the filled height of theTemperature Bar and by the
NumericTemperature Indicator below the bar. The color reference bar is a visual
indicator to quickly allow the user to determine the meaning of the color displayed
on the screen. For example, if the Temperature Measurement Zone is pointed to an
object at 1000° F (538º C) the bar fills to the mark located above the 900º F
(482º C).
TI BASIC PLUS Mode Indicator (Optional Features)
TI BASIC PLUS mode provides access to additional optional features of the
Bullard NXT, including Electronic ThermalThrottle (ETT), digital zoom (2X / 4X), and
USB connection for downloading recorded video files, dependent on your unit’s
configuration.
To activate TI BASIC PLUS mode, depress the left button for approximately three (3)
seconds.TheTI BASIC PLUS mode is indicated by the “plus sign” (+) transparent
square box in the lower left of the display. In this mode, icons associated with
features appear in the center left of the display (Additional Information Area).
Depressing the Green power button always reverts toTI BASIC Mode.
Electronic Thermal Throttle® (ETT)
As an optional feature, your Bullard NXT may be equipped with the Electronic
ThermalThrottle (ETT), which is a hot-spot indicator ideal for locating hot spots
during overhaul and size-up, searching for overheated electrical equipment, finding
victims, and clarifying objects in low ambient temperature (non-fire) situations.
When engaged, ETT senses the hottest area in the scene and colors it blue. If
ETT is engaged while viewing an object /scene and most of the area is the same
temperature, a greater amount of the scene is colored blue.
To engage ETT, enter TI BASIC PLUS mode by depressing the left button for
approximately three (3) seconds. After the PLUS mode indicator is illuminated in
the lower left of the display, then press the left button again to engage ETT. “TT**”
will appear on the screen. As the algorithm engages more of the scene, the blue
will become lighter in hue to help differentiate objects in the scene. Cycling through
the scene and sensitivity adjustment displays the “TT” symbol and a corresponding
number in the upper left hand corner of the display. The “TT” indicates “Thermal
Throttle” mode. The number (0-99) is a reference point indicating the relative level
of ETT engagement; by itself it has no specific meaning. Most of the benefits of the
ETT are accomplished with the first few presses of the button.While engaged, the
ETT sensitivity is adjusted by the left and right buttons.
Digital Zoom
As an optional feature, your Bullard NXT may be equipped with 2X and 4X digital
zoom capability. This feature is available in TI BASIC PLUS mode only. If present
in your unit’s configuration, to enable this functionality, depress the left button for
approximately three (3) seconds. After the PLUS mode indicator is illuminated in the
lower left of the display, then depress both buttons again for approximately three
(3) seconds to engage the zoom function. A second long-press of both buttons will
change from 2X to 4X zoom, and a third long-press of both buttons reverts to the
Imager’s standard view with no zoom.
SceneCatcher Digital Video Recorder (DVR)
As an optional feature, your Bullard NXT may be equipped with a SceneCatcher
DVR.
If so equipped, the DVR is accessible from withinTI BASIC orTI BASIC PLUS
Mode.To activate the DVR in either mode, press and hold the right button for
approximately three (3) seconds, until a red circle appears on the left side of the
display. This indicates recording to the unit’s internal memory. To deactivate the
DVR, press and hold the right button until the red circle disappears.To download
recorded video, connect the imager to a computer via the Micro USB port on the
bottom of the imager. When connected in this manner and powered ON, the internal
Secure Digital (SD) card will behave as any other USB mass storage device (i.e.
flash key, hard drive, etc).
NOTE:
Upon initial imager startup, the SceneCatcher DVR will not be available for 8
seconds while it initializes. During this time, the red dot will be displayed with
an “X” crossing it.
The SceneCatcher DVR has 8 GB of solid state memory, which will store more than
5.5 hours of video. When storage is full, the unit automatically overwrites the oldest
file available. Video files are recorded for a maximum of 3 minutes each.That is, if a
video being recorded is longer than 3 minutes, it will be stored in 3-minute segment
files.To make it easier to manage multiple videos from differentThermal Imagers,
the video file names have the following format: AANNNNNN.avi, where AA is an
alphabetic combination and NNNNNN is a numeric pattern.
Charging the Battery
Your Bullard NXT’s battery can be charged with one of three charging systems: the
included Wireless Desktop Charger, the included USB Wall Charger, or the optional
WirelessTruck Mount Charger. To charge a battery in the Desktop orTruck Mount
chargers, place the imager on the charger. When seated correctly, a BLUE LED
on the right side of the charger indicates a connection with the imager. When the
connection has been verified and the battery is charging, the Bullard NXT’s power
button LED will pulse RED. When fully charged, the same LED will change to steady
GREEN. Note: more detailed information is available in the user’s manual for these
charging devices.
To charge with the USB Wall Charger, open the USB cover located on the rubber
boot at the bottom of the display side of the imager. Plug the USB power cord into a
dedicated wall outlet using the included AC adapter. When the connection has been
verified and the battery is charging, the Bullard NXT’s power button LED will pulse
RED. When fully charged, the same LED will change to steady GREEN.
With any charging system, if the Bullard NXT’s internal control software determines
that internal temperatures are too high or too low for battery charging, then the
power button will flash YELLOW until the imager’s internal temperature stabilizes
to a range appropriate for charging.This is normal operation as the battery pack
must be at moderate temperatures to support charging. Upon and while charging,
the imager’s power button pulses RED, and when fully charged, the LED displays
solid GREEN.
NOTE:
If your Bullard NXT has been stored in extremely cold temperatures for
an extended period of time, especially with a depleted battery, it may
take approximately one minute to start up.To avoid this behavior, Bullard
recommends leaving the unit attached to a charging system when not in use.
3
Bullard NXT Thermal Imager
User Manual

www.bullard.com
4
NOTES ON BATTERY CHARGING:
(1) Connection to a computer via USB is intended for the purpose of
downloading video and/or communicating with the imager. Use of the USB
computer connection is not recommended for battery charging due to
extremely slow charge speed with this method.
(2)The battery’s charging temperature range is 32º F (0°C) to +113º F
(+45°C).
(3)THE BULLARD NXT’S INTERNAL LITHIUM ION BATTERY PACK IS
DESIGNED FOR MAXIMUM LIFE WHEN THE BATTERY IS KEPT FULLY
CHARGED. BULLARD RECOMMENDS LEAVINGTHE NXT CONNECTEDTO
YOUR PREFERRED CHARGING SYSTEMWHENTHE UNIT IS NOT IN USE.
(4) Power off the imager during charging.
Hardware Reset Functions
Like most portable electronic devices with internal batteries, the Bullard NXT
is equipped with a function which permits a full hardware reset. If the imager
appears unresponsive, it may require a hardware reset. To accomplish this,
depress and hold the Power button for 30 seconds.
The Bullard NXT is also equipped with a safety feature in the battery system which
provides automatic shutoff to protect the electronics if they experience prolonged
excessive temperatures.To reset the battery’s safety circuit, plug the imager into
the included Bullard USB Power Supply.
Care and Storage Instructions
The Bullard NXTThermal Imager requires little maintenance. For best results, after
each use:
• Clean and disinfect the outside of the unit with mild soap or detergent.
• Wipe the lens with a soft cloth.
• Clean the display with a soft cloth.
• Check screw tightness on cover display.
• Store your Bullard NXT on the included Desktop Charger, the optionalTruck Mount
Charger, or in the delivery case provided. Bullard recommends leaving the unit to
charge when not in use for best performance.
• Maintain thermal imagers using a programmed system.
NOTE:
You may place department and/or company information on your Bullard NXT.
When adding stickers or other markings, ensure that you do not cover the
information label, the thermal imager lens, cover window, or the display. Do
not engrave in the plastic material as this can damage the unit and jeopardize
sealing.
NOTE:
As an option, the Bullard NXT may be ordered with aTruck Mount Charger
for installation into a vehicle. This charger is designed to be mounted in a
vehicle and securely charge and store the imager in accordance with NFPA
1901-14.1.11.2.TheTruck Mount Charger is designed for permanent vehicle
installation. Consult the Bullard XT SeriesTruck Mount instruction manual for
detailed instructions of installing in a vehicle.
Cleaning the Lens
The Bullard NXTThermal Imager lens is recessed in an impact resistant bezel
covered with a germanium lens.The lens can be cleaned with a soft cloth and soapy
water as required.
Replacing the Video Display Cover Window
The display cover has a scratch-resistant hard coating to minimize marring.
However, if heavy scratching or gouging occurs, the cover window can be replaced.
To accomplish this, remove the four Phillips screws along the sides of the window.
Lift the USB cover (lower portion of the Rear Boot) and pull over the D-ring while
pulling forward on the Rear Boot. The Rear Boot and Window will disengage from
the imager. Pull the Display Cover Window from the slot and replace it with the
new Display Cover Window. Stretch the Rear Boot/Window assembly over the
screen and feed the D-ring through the hold in the boot. Press the USB cover into
the lower housing.Take care NOT to overtighten the screws during reassembly.
(Replacement part number: XTWINDOW).
Shipment
As with all electronics with internal lithium-ion batteries, special considerations
must be observed when shipping the Bullard NXT.
When shipping the Bullard NXT, by regulation the exterior case must have a
red-bordered announcement with the following text: “CAUTION – LITHIUM ION
BATTERY – DO NOT LOAD OR TRANSPORT PACKAGE IF DAMAGED”. Additionally,
further regulations stipulate that the imager must not have greater than two bars
of battery charge if shipping by air. Air shipments must also be packed in a carton
with a secondary over-pack carton.

Service
If your Bullard NXT is not performing properly, contact Bullard Customer Service
call +1-859-234-6611. Describe the problem to the Bullard representative as
completely as possible. For your convenience, your representative will attempt to
help you diagnose or correct the problem over the phone. Before returning your
Bullard NXT, you should verify with your representative that the product should
be returned to Bullard. Bullard Customer Service will provide you with written
permission and a Return Authorization (RA) number.
If the return is a non-warranty repair, a Bullard Customer Service Representative
or your local distributor will provide you with a repair invoice estimate.To authorize
repair, you must provide a Purchase Order to your distributor for the amount of the
estimate. Once Bullard or your distributor authorizes the repair, Bullard will issue
a Return Authorization (RA) number for return of the unit to Bullard. Bullard will
repair the unit and ship it from our factory within 48 business hours. If the cost
of repairs exceeds the stated quote either 15% or greater than $100, a Bullard
representative will reestimate your repair and Bullard or your local distributor will
contact you for authorization to complete repairs. After repairs are completed and
the goods have been returned to you, Bullard or your distributor will invoice you for
the actual repair amount.
Prior to returning your Bullard NXT, decontaminate and clean the thermal imager
to remove any hazardous or contaminated materials which may have settled on
the product during use. Laws and/or shipping regulations prohibit the shipment of
hazardous or contaminated materials. Products suspected of contamination will be
professionally decontaminated at the customer’s expense.
Returned products will be inspected upon return to the Bullard facility. If the repair
is under warranty, Bullard will repair the unit and ship it from our factory within 48
business hours.
Product recycling, replacement, and retirement
Your Bullard NXT is designed to provide a long and useful life. When replacing or
retiring your Bullard NXT please contact local recycling or waste management
facilities to see if components can be recycled. When selling or transferring the
Bullard NXT, ensure compliance with export control regulations.The infrared core
in the Bullard NXT is export-controlled outside of the US and Canada. If you have
questions about proper procedures for disposing of the unit, contact Bullard.
Warranty
Bullard warrants to the original purchaser that the Bullard NXT and all features/
accessories installed in the unit as well as battery charging units, are free of
defects in materials and workmanship under intended use and service for a period
of five (5) years from date of manufacture. Bullard’s obligation under this warranty
is limited to repairing or replacing, at Bullard’s option, articles returned within the
warranty period and which, after examination, are shown to Bullard’s satisfaction
to be defective, subject to the following limitations:
a) Article must be returned to Bullard with shipping charges prepaid.
b) Article must not be altered from its original configuration.
c) Article must not have been misused, abused, or damaged in transport.
d) Maintenance and field replaceable items, if defective, are covered under
warranty for a ninety (90) day period from the date of purchase.These items
include straps, display covers, AC/DC adapters.
Review the user manuals for Bullard accessories to obtain warranty information
specific to those accessories. Since some accessories do not have user manuals,
contact Bullard if you are unsure about the warranty for a particular product or
accessory.
Bullard provides a limited lifetime warranty on the Bullard NXT’s outer shell. This
warrants that the outer shell is free of defects in materials and workmanship under
intended use and service for the original purchaser. Bullard’s obligation under this
warranty is limited to repairing or replacing, at Bullard’s option, articles that after
examination are shown to Bullard’s satisfaction to be defective, subject to the
following limitations:
a) Article must not be altered from its original configuration.
b) Article must not have been misused, abused, or damaged in transport.
c) When the outer shell is obsolete and Bullard no longer stocks the part, the limited
lifetime warranty will be terminated.
In no event shall Bullard be responsible for damages, loss of use, or other indirect,
incidental, consequential or special costs, expenses or damages incurred by the
purchaser, notwithstanding that Bullard has been advised of the possibility of such
damages.
Any implied warranties, including warranties of merchantability and fitness for
a particular purpose, are limited in duration to five (5) years from the date of
manufacture. Some states do not allow the exclusion of limitation of incidental or
consequential damages, or allow how long implied warranty last, so the above
limitations or exclusions may not apply to you. This warranty gives you specific legal
rights, and you may have other rights which vary from state to state.
5
Bullard NXT Thermal Imager
User Manual
www.bullard.com

www.bullard.com
Safety Considerations and Limitations of Use
�WARNING
EXPLOSION HAZARD. DO NOT CONNECT OR DISCONNECT THE EQUIPMENT
TO ANY CHARGER IN A HAZARDOUS LOCATION.
�WARNING
DO NOT CHARGE IN A HAZARDOUS LOCATION.
�WARNING
DO NOT SHORT CIRCUIT, CRUSH, INCINERATE, OR DISASSEMBLE.
�WARNING
RISK OF FIRE, EXPLOSION, OR BURNS.
�WARNING
ONLY CHARGE USING BULLARD DESKTOP, BULLARDTRUCK MOUNT, OR
BULLARD PROVIDED USB PLUG.
POWER SOURCE: 3.6v 6400 mAh Li-Ion 23.04 wH
INTERNALLY HOUSED, NOT FIELD REPLACEABLE
�WARNING
DO NOT ATTEMPT TO DISASSEMBLE THE BULLARD NXT THERMAL IMAGER.
IFTHE UNIT IS NOT FUNCTIONING PROPERLY, RETURN ITTOTHE BULLARD
SERVICE CENTER FOR EVALUATION.
�WARNING
DO NOT ATTEMPT TO REPLACE THE INTERNAL BATTERY PACK. RETURN IMAGER
TO BULLARD SERVICE CENTER. BATTERY PACK MUST BE RECYCLED OR
DISPOSED OF PROPERLY.
�WARNING
DO NOT USE ANY CHARGER OTHER THAN THAT SPECIFICALLY PROVIDED BY
BULLARD FOR USE WITH THE BULLARD NXT THERMAL IMAGER.
�WARNING
THERMAL IMAGING IS NOT ATECHNOLOGY DESIGNEDTO REPLACE CURRENT
FIREFIGHTINGTACTICS. RATHER, IT IS A TOOL WHICH ALLOWS THE
FIREFIGHTERTO BE MORE EFFECTIVE ANDTO MAKE BETTER DECISIONS.
FIREFIGHTERS CANNOT STOP USING BASIC FIREFIGHTING SAFETY TACTICS.
ALL FIREFIGHTERS SHOULD RECEIVE PROPERTRAINING ON: HOW THERMAL
IMAGERS WORK, THEIR USES AND LIMITATIONS, IMAGE INTERPRETATION,
AND SAFETY CONSIDERATIONS FORTHERMAL IMAGING USE.
�WARNING
THE BULLARD NXTTHERMAL IMAGER IS EXTREMELY SENSITIVE TO INTENSE,
RADIANT HEAT SOURCES. NEVER POINTTHE BULLARD NXTTHERMAL IMAGER
AT THE SUN OR ANY OTHER SOURCE OF EXTREME RADIANT HEAT, AS THIS
COULD CAUSE SEVERE DAMAGE.
�WARNING
DO NOT USE SOLVENTS OR PAINTTHINNERSTO CLEANTHE BULLARD NXT
THERMAL IMAGER ASTHEY COULD PERMANENTLY MAR THE SURFACE
OR DEGRADE THE PROTECTIVE PROPERTIES OF THE CASING. DO NOT
INTENTIONALLY SUBMERGETHE UNIT UNDER WATER OR SUBJECTTHE UNIT
TO HIGH PRESSURE WATER. FOLLOW CARE INSTRUCTIONS
(SEE CARE INSTRUCTIONS).
�WARNING
BATTERY PACK CHARGING TEMPERATURE 0ºC - 45ºC
�WARNING
ALWAYS USE THE CORRECT CHARGER AND REFERTOTHE MANUFACTURER’S
INSTRUCTIONS FOR PROPER CHARGING INSTRUCTIONS.
RETAIN THE ORIGINAL PRODUCT LITERATURE FOR FUTURE REFERENCE.
6

Technical Specifications
Physical
Configuration Small HandheldThermal Imager
Weight (w/ battery) 2.4 lbs. (1.09 kg)
Dimensions H 5.4” (137 mm), W 4.6 (117 mm), L 8.2” (208 mm)
Housing Material Ultem®Thermoplastic
Upper Housing Colors Red (standard), Metallic Blue, Blue, Yellow,
Lime-Yellow, Orange, White, Black
Lower Housing Color Black
Electrical
Power Source Lithium-ion Rechargeable Battery
Battery Capacity 6400 mAh
Battery Cycles > 800 @ 70% Capacity
Start-upTime < 4 Seconds
OperatingTime >6 hours (with or without DVR operating); 7-8 hours
in routine conditions
RechargeTime 5 hours from fully depleted
Infrared Detector
DetectorType Microbolometer
Detector Sensing Material Vanadium Oxide
Detector Resolution 320 x 240 or 240 x 180
Spectral Response 7-14 µ
Update Rate 60 Hz
NETD < 30 mK
Dynamic Range 1100° F (593º C)
Pixel Pitch 17 µm
Video Polarity White-Hot
Lens
Material Germanium
Field of View 31° V x 40° H
Focus 1 m to ∞
Speed f/1.3
Display
Type Digital, Liquid Crystal Display (LCD)
Size 3.5” (89 mm) DiagonalTFT Active Matrix
Pixel Format RGB
Brightness 500 cd/m2 (minimum)
Contrast Ratio 350:1 (typical)
Viewing Angle (Typical) Top = 60°, Bottom = 40°, Left / Right = 60°
Standard Features and Accessories
Temperature Measurement Numeric and Bar Style
Super Red Hot Colorization Engages automatically
above 500°F (260º C)
Optional Features and Accessories (if so equipped)
ElectronicThermalThrottle Blue Hot Spot Colorization (Manually activated)
Digital Zoom 2X/4X
SceneCatcher Digital Video Recorder (DVR)
Video Format NTSC
Video FileType AVI
Video Image Size 720 x 480
Video RecordTime 5.5 hours
Connection Micro USB
Retract Strap
Hard Case
Charging Systems
Wireless Desktop Charging System (standard)
WirelessTruck Mount Charger (optional)
Performance
500° F (260º C) Heat Resistance 5 minutes with no damage to electronics
300° F (150 ºC) Heat Resistance 15 minutes of continued operation
with no damage
-4° F (-20º C) Cold Resistance Continued operation
Water Resistance IP67
Impact Resistance 2 meter drops on concrete with no damage
Hazardous Locations NEC/CEC Class 1, Division 2
ANSI/ISA-12.12.01-2015
CSA-C22.2 No. 60079-0:15
IEC 60079-0:2011, MOD
Encapsulation IP67 (ANSI/IEC 60529)
Radiated Emissions FCC 47 CFR Part 15B EN 55022:2006
Electromagnetic Immunity IEC 61000-6-1:2005 EN 55024:2010
Internal Battery UN/DOT 38.3 IEC 62133 2nd edition
NFPA 1801-2013,
Standard onThermal Imagers for the Fire Service
Warranty
Five (5) years on both thermal imager and battery
7
www.bullard.com
Bullard NXT Thermal Imager
User Manual

ISO 9001
certified
60510011229A AM EN (1116)
©2016 Bullard. All rights reserved.
Electronic Thermal Throttle is a registered
trademark of Bullard.
www.bullard.com
Americas:
Bullard
1898 Safety Way
Cynthiana, KY 41031-9303 • USA
Toll-free within USA: 877-BULLARD (285-5273)
Tel: +1-859-234-6616
Fax: +1-859-234-8987
Europe:
Bullard GmbH
Lilienthalstrasse 12
53424 Remagen • Germany
Tel: +49-2642 999980
Fax: +49-2642 9999829
Asia-Pacific:
Bullard Asia Pacific Pte. Ltd.
LHK Building
701, Sims Drive, #04-03
Singapore 387383
Tel: +65-6745-0556
Fax: +65-6745-5176
For accessories, upgrades and replacement parts, visit www.bullard.com,
call 877-BULLARD or, + 1-859-234-6611 or contact your local Bullard distributor.
Other manuals for NXT
1
Table of contents
Other Bullard Laboratory Equipment manuals

Bullard
Bullard Powerhouse User manual

Bullard
Bullard TI User manual

Bullard
Bullard TACSIGHT User manual

Bullard
Bullard TXS User manual

Bullard
Bullard NXT User manual

Bullard
Bullard TacSight S2 User manual

Bullard
Bullard MX User manual

Bullard
Bullard T4X User manual

Bullard
Bullard EcoX User manual

Bullard
Bullard TI Commander User manual