AIR-EAGLE®SR
2.4 GHz RF Receiver
RELAY & FREQUENCY SET-UP
The unit is shipped from the factory with SEL1 switches in the open
positions. All four relays will operate as maintained momentary and unit is
receiving commands on frequency one. If you wish to change these
default settings, followthe instructions onthe table below.
1) Remove power from unit
2) Remove top cover.
3) Select desired relay operation and/or network frequency using table
below.
4) Reattach cover and apply power.
5) Programming is now complete.
Relay #1 momentary (default)
Relay #2 momentary (default)
Relay #3 momentary (default)
Relay #4 momentary (default)
Maintained Momentary –Relay mimics button or input –when
depressed or closed, relay will be energized; when released, relay de-
energizes
Toggle Latch –Relay changes (and holds) its state each time the
corresponding button or input is depressed or closed.
SW8& SW9 Not used on this model
100-250 VAC, 5 W, 50/60 Hz
SPDT 5 amp @ 120VAC or 30VDC per
channel
Note: Range figures are estimates, based on free-air terrain with limited sources of
interference. Actual range will vary based on transmitting power, orientation of transmitter
and receiver, height of transmitting antenna, height of receiving antenna, weather
conditions, interference sources in the area, and terrain between receiver and transmitter,
including, but not limited to, indoor and outdoor structures such as walls, metal objects,
trees, buildings, hills, and mountains.
Eight independent network frequencies
Polycarbonate, IP66 (NEMA 4)
Standard Antenna (Included):
2.4GHz TNC “Rubber Duck” Antenna
Mobile/Base Antennas –
Used to help achieve max range in both non line of sight and line
of sight applications. - Contact BWI Eagle for recommendations
2.4GHz Thru-Hole Mount Mobile Antenna
2.4GHz Magnet Mount Mobile Antenna
2.4GHz Omni Directional Base Antenna
2.4GHz Yagi Directional Base Antenna
High Quality Coax Cables –
Used to connect external high gain antennas to control unit
Flex Coax Cable w/Connectors –Available in
5’,15’,25’,30’,40’,60’,80’,100’ Lengths
49-4000-XX
(XX = # of
Feet)
Bulkhead Extensions –
Used to provide an external antenna connection whenmounting
control unit inside another enclosure
TNC Male to TNCBulkhead Cable Assembly -
Available in 2’, 4’, 7’ Lengths
49-5004-X-ISO
(X = # of Feet)
LIMITED WARRANTY STATEMENT
BWI Eagle Inc. warrants theAir-Eagle Remote Control System, if properly
used and installed, will be free from defects inmaterial and workmanship
for a period of 1 year after date of purchase. Said warranty to include the
repair or replacement of defective equipment. This warranty does not
cover damage due to external causes, including accident, problems with
electrical power, usage not in accordance with product instructions,
misuse, neglect, alteration, repair,improper installation, or improper
testing. This limited warranty, and any implied warranties that may exist
under state law, apply only to the original purchaser of the equipment, and
last only for as long as such purchaser continues to owntheequipment.
This warranty replaces all other warranties, express or implied including,
but not limited to, the implied warranties or merchantability and fitness for
a particular purpose. BWI Eagle makes no express warranties beyond
thosestated here. BWI disclaims without limitation, implied warranties of
merchantability and fitness for a particular purpose. Some jurisdictions do
not allowthe exclusion of implied warranties so this limitation may not
apply to you. To obtain warranty service, contact BWI Eagle for a return
material authorization. When returning equipment to BWI Eagle, the
customer assumes the risk of damage or loss duringshipping and is
responsible for the shipping costs incurred.
DOCUMENT DATE: 3/7/2022 / PRODUCT REV. 10
105 Bonnie Drive
Butler, PA 16002
(724) 283-4681
Fax (724) 283-5939
www.bwieagle.com