AIR-EAGLE®SR
2.4 GHz RF Receiver
RELAY OPERATION
Relays energize based on commands received fromthe transmitter. See
table below for relay mode configuration forthis receiver:
TX BUTTON
OR INPUT
ACTIVATED
Relay #1 Energizes, Maintained Momentary
Relay #2 Energizes, Maintained Momentary
Relay #3 Energizes, Maintained Momentary
Relay #4 Energizes, Maintained Momentary
Maintained Momentary –Relay mimics button or input –when
depressed or closed, relay will be energized; when released, relay
de-energizes
DIGITAL ADDRESS & FREQUENCY SET-UP
The unit is shipped from the factory with SEL1 switches set so that unit is
receiving commands on Digital Address “1” / Frequency “1”. If you wish to
change these default settings, follow the instructions onthe table below.
1) Remove power from unit.
2) Remove top cover.
3) Select desired digital address and/or network frequency using table
below.
4) Reattach cover and apply power.
5) Programming is now complete.
SW8& SW9 Not used on this model
100-250 VAC, 5 W, 50/60 Hz
SPDT 5 amp @ 120VAC or 30VDC per
channel
Note: Range figures are estimates, based on free-air terrain with limited sources of
interference. Actual range will vary based on transmitting power, orientation of transmitter
and receiver, height of transmitting antenna, height of receiving antenna, weather
conditions, interference sources in the area, and terrain between receiver and transmitter,
including, but not limited to, indoor and outdoor structures such as walls, metal objects,
trees, buildings, hills, and mountains.
Sixteen independent digital addresses
Eight independent network frequencies
Polycarbonate, IP66 (NEMA 4)
Standard Antenna (Included):
2.4GHz TNC “Rubber Duck” Antenna
Mobile/Base Antennas –
Used to help achieve max range in both nonline of sight andline of
sight applications. - Contact BWI Eagle for recommendations
2.4GHz Thru-Hole Mount Mobile Antenna
2.4GHz Magnet Mount Mobile Antenna
2.4GHz Omni Directional Base Antenna
2.4GHz Yagi Directional Base Antenna
High Quality Coax Cables –
Used to connect external high gain antennas to control unit
Flex Coax Cable w/Connectors –Available in
5’,15’,25’,30’,40’,60’,80’,100’ Lengths
49-4000-XX
(XX = # of
Feet)
Bulkhead Extensions –
Used to provide an external antenna connection whenmounting
control unit inside another enclosure
TNC Male to TNCBulkhead Cable Assembly -
Available in 2’, 4’, 7’ Lengths
49-5004-X-ISO
(X = # of Feet)
LIMITED WARRANTY STATEMENT
BWI Eagle Inc. warrants the Air-Eagle Remote Control System, if properly used and
installed, will be free from defects in material and workmanship for a period of 1 year after
date of purchase. Saidwarranty to include the repair or replacement of defective equipment.
This warranty does not cover damage due to external causes, including accident, problems
with electrical power, usage not in accordance with productinstructions, misuse, neglect,
alteration, repair, improper installation, or improper testing. This limited warranty, and any
implied warranties that may exist understate law, apply only to the original purchaser of the
equipment, and last only for as long assuch purchaser continues to own the equipment.
This warranty replaces all other warranties, express or implied including, but not limited to,
the implied warranties or merchantability and fitness for a particular purpose. BWI Eagle
makes no express warranties beyond those stated here. BWI disclaims without limitation,
implied warranties of merchantability and fitness for a particular purpose. Some jurisdictions
do not allow the exclusion of implied warranties so this limitation may not apply to you. To
obtain warranty service, contact BWI Eagle for a return material authorization. When
returning equipment to BWI Eagle, the customer assumes theriskof damage or loss during
shipping and is responsible for the shipping costs incurred.
DOCUMENT DATE: 11/04/2021 / PRODUCT REV. 10