Byan 500A series User manual

BYAN SYSTEM, INC.
413 LINDEN
LUSK, WY 82225
(800) 223-2926
MODEL 500A/500B SERIES
VEHICULAR SWING
GATE OPERATOR
INSTALLATION AND TECHNICAL MANUAL
BYAN SYSTEMS, INC. OF LUSK, WYOMING, DEMANDS THAT YOU AS AN INSTALLER
INFORM YOUR CUSTOMER OF ALL SAFETY EQUIPMENT THAT SHOULD BE INSTALLED
ON EACH JOB SITE. THIS IS IN ACCORDANCE WITH YOUR LEGAL LIABILITY TO YOUR
CUSTOMER. ENSURE THAT THE PROTECTION AND WARNING SIGNALING DEVICES ARE
OPERATIONAL AND VISIBLE. THESE STEPS WILL AID IN YOUR DEFENSE SHOULD YOU
BECOME INVOLVED IN LITIGATION REGARDING INJURY OR DAMAGE.
ATTENTION: ALL INSTALLERS EXPERIENCED OR NOT PLEASE REVIEW
PAGES 4 AND 9 BEFORE YOU INSTALL THIS ACTUATOR.
P.O. BOX 1384 FAX (307) 334-2028

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
1
TABLE OF CONTENTS
DESCRIPTION PAGE NO.
USAGE CLASSES FOR VEHICULAR GATES 2
TECHNICAL DATA ABOUT THE OPERATOR 3
BEFORE YOU INSTALL 4
DURING INSTALLATION PROCEDURES 4
INSTALLATION COMPLETION/FOLLOW UP 5
INSTALLING THE OPERATOR 6
ADJUSTING THE OPERATOR 7
PURGING THE OPERATOR 7
HYDRAULIC FLUID 8
MANUAL BYPASS 8
MOUNTING GEOMETRY 9
MOUNTING BRACKET LOCATION 10
MOUNTING DIMENSIONS 11
WIRING THE CONTROL AND ACCESSORIES 12
CONNECTING THE OPERATOR 18
LOOP CONNECTION 20
OVERVIEW 23
WARRANTY 25
END USER SAFETY HANDOUT 26
CUSTOMER ACKNOWLEDGMENT 28

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
2
USAGE CLASSES FOR VEHICULAR GATES
CLASS I – RESIDENTIAL VEHICULAR GATE OPERATOR
A VEHICULAR GATE OPERATOR (OR SYSTEM) INTENDED FOR USE IN A HOME OF ONE TO
FOUR SINGLE FAMILY DWELLING, OR A GARAGE OR PARKING AREA ASSOCIATE
THEREWITH.
CLASS II – COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR
A VEHICULAR GATE OPERATOR (OR SYSTEM) INTENDED FOR USE IN A COMMERCIAL
LOCATION OR BUILDING SUCH AS A MULTI-FAMILY HOUSING UNIT (FIVE OR MORE
SINGLE FAMILY UNITS), HOTEL, GARAGES, RETAIL STORES, OR OTHER BUILDING
SERVICING THE GENERAL PUBLIC.
CLASS III – INDUSTRIAL/LIMITED ACCESS VEHICULAR GATE OPERATOR
A VEHICULAR GATE OPERATOR (OR SYSTEM) INTENDED FOR USE IN AN INDUSTRIAL
LOCATION OR BUILDING SUCH AS A FACTORY OR LOADING DOCK AREA OR OTHER
LOCATION NOT INTENDED TO SERVICE THE GENERAL PUBLIC.
CLASS IV – RESTRICTED ACCESS VEHICULAR GATE OPERATOR
A VEHICULAR GATE OPERATOR (OR SYSTEM) INTENDED FOR USE IN A GUARDED
INDUSTRIAL LOCATION OR BUILDING SUCH AS AN AIRPORT SECURITY AREA OR OTHER
RESTRICTED ACCESS LOCATION NOT SERVICING THE GENERAL PUBLIC, IN WHICH
UNAUTHORIZED ACCESS IS PREVENTED VIA SUPERVISION BY SECURITY PERSONNEL.

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
3
500 SERIES TECHNICAL DATA
MODEL 500: 115 VAC SINGLE PHASE
ELIMINATOR SERIES BUILT-IN THERMAL OVERLOAD
CAPACITOR RATING: 40UF / 10UF
STANDARD WORKING PRESSURE: 1350 PSI
MAXIMUM WORKING PRESSURE: 1750 PSI
PUMP: SPURGEAR.50LTR/MIN.
MOTOR: 1/6HORSEPOWER
AMPERAGE DRAW: 4.0 AMPS
OPERATOR LENGTH WITH PISTON RETRACTED 27.72 INCHES
AND REAR BRACKET AND SWIVEL JOINT INSTALLED
OPERATOR LENGTH EXTENDED WITH REAR 35.59 INCHES
BRACKET AND SWIVEL JOIN INSTALLED
OPERATOR WIDTH: 3.39 INCHES
OPERATOR HEIGHT: 4.33 INCHES
OPERATOR SPEED TO 90 DEGREES: 12 SEC. APP.
PISTON STROKE: 200 MM / 7.87 INCHES
AMBIENT OPERATOR TEMPERATURE RANGE: -60 TO 220 DEGREES F
HYDRAULIC FLUID: SHELL TELLUS T-15
THIS PATENTED NEW CONCEPT IN LINEAR ACTUATOR DESIGN ELIMINATES THE
NEED FOR PHYSICAL STOPS. THE VALVE DESIGN CUSHIONS THE LAST HALF
INCH OR ABOUT THE LAST 5 TO 10 DEGREES OF PISTON TRAVEL ALLOWING THE
PISTON TO REACH END OF STROKE IN BOTH DIRECTIONS AND PREVENT
INTERNAL DAMAGES.
• OPERATOR BODY FABRICATED IN ANODIZED ALUMINUM
• FRONT AND REAR FLANGES ARE CAST ALUMINUM
• ALL INTERNAL COMPONENTS ARE CAST AND MACHINED
• INTERNAL COMPONENTS ARE BATHED IN OIL SO VIRTUALLY NO
MAINTENANCE REQUIRED.

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
4
BEFORE INSTALLATION
1. VERIFY THE GATE POST IS PLUM AND GATE LEAF SWINGS FREELY.
2. PERFORM ANY REQUIRED MAINTENANCE BEFORE CONTINUING.
3. VERIFY THE COMMERCIAL POWER CIRCUIT BREAKERS ARE ISOLATED AND RATED FOR
THE SPECIFIC LOAD. VISUALLY ENSURE THE CIRCUIT BREAKERS ARE IN THE “OFF”
POSITION AND MARK THE BREAKER USED.
4. IF ANY PRE-CONSTRUCTION WIRING HAS BEEN INSTALLED, VISUALLY INSPECT AND
CONFIRM PROPER SIZING AND COMPLIANCE TO CODE.
5. AUTOMATIC VEHICULAR GATES ARE NOT APPROVED FOR PEDESTRIAN TRAFFIC;
HOWEVER, THEY CAN CREATE HAZARDS TO UNSUSPECTING PEDESTRIANS AND
DOMESTIC ANIMALS. ANY GATE, CONSTRUCTED WITH REACHABLE PINCH POINTS, OR
HAS A SURFACE AREA THAT ALLOWS ARMS OR LEGS TO PASS THROUGH, IS A
POTENTIAL HAZARD. RECOMMEND AND PROVIDE SAFE GUARDS AGAINST THESE
HAZARDS.
6. REMOVE THE “END USER SAFETY ADVISORY HANDOUT” FROM THIS MANUAL. REQUEST
THE END USER REVIEW THE MATERIAL AND SIGN IT. COLLECT THE HANDOUT WHEN
THE JOB IS COMPLETE.
DURING INSTALLATION
1. LOCATE THE ELECTRONIC CONTROLS FAR ENOUGH FROM THE GATE SO THE END USER
CAN OBSERVE, BUT NOT TOUCH, THE GATE WHILE OPERATING THE CONTROLS.
2. WHEN CONNECTING THE WIRING FROM THE COMMERCIAL POWER SOURCE TO THE
CONTROL PANEL, MAKE SURE YOU HAVE PROVIDED A PROPER EARTH GROUND. IF
USING A METAL ENCLOSURE, CONNECT THE GROUND TO THE ENCLOSURE BEFORE
CONNECTING TO THE GATE OPERATORS. NO GROUND IS TO CONNECTING TO THE GATE
OPERATORS. NO GROUND IS TO CONNECT DIRECTLY TO THE MICROPROCESSOR
CONTROL.
3. OBSERVE ALL WIRING REQUIREMENTS ESTABLISHED BY THE NATIONAL ELECTRICAL
CODE AND/OR THE AUTHORITY HAVING JURISDICTION.
4. MOUNT HE LINEAR ACTUATOR AS CLOSE TO THE CENTER OF THE GATE LEAF AS
POSSIBLE. THIS WILL HELP BALANCE THE WHIPPING MOTION OF THE GATE WHEN THE
OPERATOR REACHES END OF THE PISTON STROKE.
5. ISOLATE THE LINEAR ACTUATOR WHEN WELDING TO PREVENT ANY CURRENT FROM
PASSING THROUGH THE OPERATOR AND DAMAGING THE MOTOR OR OTHER
COMPONENTS.

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
5
INSTALLATION COMPLETION
1. “REMOVE” ALL DEBRIS AND OBSTRUCTIONS FROM THE TRAVEL PATH OF THE
GATE LEAF(S).
2. TURN ON AND LABEL THE COMMERCIAL POWER CIRCUIT BREAKER AND
REMOVE THE “USED” TAG YOU INSTALLED AT THE BEGINNING OF THE PROJECT.
3. USING THE MANUAL BYPASS, POSITION THE GATE LEAF AT 45 DEGREES. PRESS
THE TEST BUTTON ON THE CM2-T CONTROL BOARD. THE FIRST SIGNAL WILL
ALWAYS BE TO OPEN. IF THE OPERATOR RUNS TO THE CLOSED POSITION, TURN
OFF THE COMMERCIAL POWER AND REVERSE THE MOTOR CONNECTIONS ON
PINS 1 AND 3.
4. OPERATE THE ACTUATOR SEVERAL TIMES UNTIL YOU CAN DETECT A RISE IN
THE FLUID TEMPERATURE. THIS CAN BE DONE BY PLACING YOUR HAND ON THE
TOP OF THE OPERATOR AT THE REAR.
5. PURGE AND ADJUST THE OPERATOR AS DESCRIBED IN THE PURGING AND
ADJUSTMENT SECTION.
6. INSTRUCT THE END USER HOW TO MANUALLY RELEASE THE GATE IN THE
EVENT OF A POWER FAILURE.
7. INSTRUCT THE END USER HOW TO PROPERLY OPERATE THE GATE AUTOMATION
AND SAFETY FEATURES THEREOF.
8. COLLECT THE “SIGNED” END USER SAFETY HAND OUT. BY THEIR SIGNATURE,
THE END USER ACKNOWLEDGES THEIR UNDERSTANDING OF THEIR
RESPONSIBILITIES OF OWNING, OPERATING, AND MAINTAINING A VEHICULAR
AUTOMATIC GATE OPERATING SYSTEM.

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
6
INSTALLING THE OPERATOR
! ADVISORIES!
A. THIS LINEAR ACTUATOR MUST ME MOUNTED SO THE PISTON FULLY EXTENDS AND
FULLY RETRACTS. WHEN FULLY RETRACTED THERE SHOULD BE INCH PISTON LEFT
OUT OF THE FRONT.
B. THIS LINEAR ACTUATOR HAS AN OFFSET BETWEEN THE FRONT AND REAR MOUNTING
BRACKET. THE FRONT BRACKET IS ABOUT 3/16+N OF AN INCH LOWER THAN THE REAR
BRACKET, REVIEW THE BRACKET ALIGNMENT DETAIL FOR THE OFFSET DIMENSION.
1. SCRIBE THE CENTERLINE OF THE GATE LEAF ONTO THE GATEPOST.
2. MEASURE FOR THE OFFSET DESCRIBED IN THE ADVISORY #B AND SCRIBE ANOTHER
LINE.
3. CUT THE REAR MOUNTING BRACKET IN ACCORDANCE WITH THE DIMENSIONS
SPECIFIED ON THE MOUNTING GEOMETRY DETAIL.
4. WELD THE REAR MOUNTING BRACKET TO THE GATE POST.
5. DETERMINE THE “C” DIMENSION AND CUT THE FRONT MOUNTING BRACKET TO THE
PROPER LENGTH.
6. EXTEND THE PISTON TO FULLY EXTENDED POSITION. THIS CAN BE ACHIEVED BY
TEMPORARILY CONNECTING THE CONTROL PANEL TO THE OPERATOR AND USING THE
MOTOR TO EXTEND THE PISTON, PRODUCING 9 7/8” OF PISTON. IT IS VERY IMPORTANT
WITH THE “600A” THAT THE PISTON “BOTTOMS OUT IN BOTH DIRECTIONS”.
7. SCREW THE “I” BOLT INTO THE END OF THE PISTON TO OF THE LENGTH OF THE
THREADS.
8. ATTACH THE OPERATOR TO THE FRONT MOUNTING BRACKET.
9. WITH THE GATE IN THE FULL CLOSED POSITION, LEVEL THE OPERATOR AND SCRIBE
THE LOCATION FOR THE FRONT MOUNTING BRACKET.
10. REMOVE THE FRONT MOUNTING BRACKET FROM THE FRONT OF THE GATE OPERATOR
AND WELD IT TO THE GATE LEAF AT THE SCRIBED LOCATION.
11. ATTACH THE OPERATOR TO THE FRONT MOUNTING BRACKET.
12. WITH THE OPERATOR IN MANUAL BYPASS, OIL FILLER CAP, SCREW ON, SWING THE
GATE OPEN AND CLOSED ABOUT 6 TIMES SLOWLY, TO PURGE THE AIR FROM THE
VALVE SYSTEM. SLOWLY OPEN THE FILLER CAP TO EXPEL ANY AIR IN THE OPERATOR.

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
7
13. ATTACH AN 18/4 STRANDED S.O. CORD APPROVED FOR OUTDOOR USE AS PER THE
STRAIN RELIEF ASSEMBLY TO THE OPERATOR PER THE ELECTRICAL CONNECTION
DETAILS.
NOTE: IT IS HELPFUL TO INSTALL A SINGLE GANG WEATHER PROOF BELL BOX ON THE
GATE POST ACROSS FROM THE OPERATOR. THEN WIRE FROM THE CONTROL BOX CAN BE
PULLED TO THIS POINT AND CONNECTED TO THE S.O. CORD INSIDE THE BELL BOX.
PURGING THE OPERATOR
THIS IN NOT REQUIRED UNLESS THE OPERATOR RUNS ERRATIC
SOMETIMES DURING SHIPPING THE “500” SERIES OPERATOR GETS TURNED UPSIDE DOWN
AND REQUIRES THE VALVE SYSTEM TO BE PURGED AFTER YOU HAVE COMPLETED THE
INSTALLATION. THIS CAN BE NOTICED IF THE OPERATOR IS JERKING OR RUNS UNEVEN.
WITH THE ALLEN WRENCH PROVIDED UNDER THE LOCKING CAP, TURN THE MANUAL
BYPASS VALVE COUNTER CLOCKWISE UNTIL THE OPERATOR RELEASES. SLOWLY SWING
THE OPERATOR FULLY OPEN AND CLOSED 6 TO 7 COMPLETE CYCLES. THEN, SLOWLY
REMOVE THE FILL CAP ON THE REAR FLANGE OF THE OPERATOR TO EXPEL THE AIR.
REPLACE THE FILL CAP.
TIGHTEN THE BYPASS VALVE WITH THE ALLEN WRENCH AND GIVE THE OPERATOR A
SIGNAL TO RUN. WHILE THE MOTOR IS RUNNING, OPEN AND CLOSE THE BYPASS VALVE
PAUSING BETWEEN OPEN AND CLOSE. DO THIS 10 TO 12 TIMES. THEN REMOVE THE FILL
CAP TO EXPEL ANY AIR IN THE OPERATOR. REPLACE THE OIL FILLER CAP SCREW AND
TIGHTEN ONLY SNUG.
ADJUSTING THE OPERATOR
THE PRESSURE ADJUSTMENT SCREW IS FOUND UNDER THE LOCKING CAP ON THE TOP OF
THE OPERATOR. LOOKING FROM THE REAR TO THE FRONT OF THE OPERATOR, THE LEFT
VALVE IS FOR RETRACTING PRESSURE AND THE RIGHT VALVE IS FOR EXTENDING
PRESSURE. CLOCKWISE INCREASES PRESSURE AND COUNTER CLOCKWISE DECREASES
PRESSURE. WITH THE MOTOR RUNNING DECREASE THE PRESSURES EQUALLY UNTIL THE
OPERATOR STOPS MOVING IN BOTH DIRECTIONS. BEGIN INCREASING PRESSURE ON BOTH
VALVES WITH THE MOTOR RUNNING. ADJUST THE PRESSURE TO WHERE YOU HAVE TO
PHYSICALLY STOP THE GATE. AT THIS POINT, EITHER INCREASE THE RETRACTING
PRESSURE OR DECREASE THE EXTENDING PRESSURE A TO OF A TURN. THE
RETRACTING PRESSURE MUST BE HIGHER.
HYDRAULIC FLUID

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
8
BYAN SYSTEMS OPERATORS US A “SHELL OIL PRODUCTS” TELLUS T-15, THIS FLUID HAS A
RELATIVELY LOW VISCOSITY SO IT WILL START TO FLOW QUICKLY ON COLD DAYS. WHEN
THE FLUID RISES TO OPERATING TEMPERATURE, THERE IS NO RUSH OF THIN FLUID
CAUSING POOR HYDRAULIC PERFORMANCE, OR WORSE YET, EXCESSIVE PUMP WEAR,
FAILURE AND EXPENSIVE DOWNTIME.
TELLUS FLUIDS MINIMIZE THE EFFECT TEMPERATURE HAS ON VISCOSITY, AND RESISTS
THE SHEARING ACTION OF HIGH SPEED PUMPS BY MAINTAINING THEIR STABLE VISCOSITY
LONGER.
THERE IS A ZINC TYPE ADDITIVE IN THE FLUID TO HELP IMPEDE WEAR AND PREMATURE
REPLACEMENT. IT HELPS PREVENT CORROSION TO METALS AND IS DESIGNED TO BE
COMPATIBLE WITH HOSES, SEALS AND OTHER ELASTOMER PRODUCTS.
TELLUS T-15 READILY SEPARATES AIR AND WATER TO PREVENT FOAMING, KEEPING THE
FLUID FIT AND DIELECTRIC STRENGTH HIGH.
WHERE TO BUY SHELL TELLUS FLUIDS
AT YOUR NEAREST SHELL DISTRIBUTOR, BYAN SYSTEMS DISTRIBUTOR, OR AT BYAN
SYSTEMS WAREHOUSE.
FLUID AND YOUR OPERATOR
THE OPERATOR HOLDS APPROXIMATELY 1 QUART OF FLUID. THE PROPER LEVEL CAN BE
OBSERVED THROUGH THE OIL FILLER TUBE, LOCATED ON THE TOP OF THE REAR FLANGE
OF THE OPERATOR, WITH THE PISTON IN THE RETRACTION POSITION, THE FLUID SHOULD
BE VISIBLE AT THE BOTTOM OF THE TUBE, LEVEL WITH THE CURVED SECTION OF THE
TUBE. THE 500 SERIES OPERATOR HAS A PRESSURED CHAMBER SO DO NOT OVERFILL. THE
PUMP WILL INTERMITTENTLY FAIL TO DRAW FLUID AND WILL FAIL TO RUN IN ONE
DIRECTION OR THE OTHER.
MANUAL BYPASS
THE MANUAL BYPASS VALVE IS FOR THE ABILITY TO RELEASE THE OPERATOR IN THE
EVENT OF A POWER FAILURE OR MALFUNCTION. IT IS LOCATED UNDER THE KEYED CAP
ON TOP OF THE OPERATOR. A METRIC ALLEN WRENCH IS SUPPLIED IN THE CAP TO
RELEASE THE BYPASS VALVE. TURN THE VALVE COUNTER CLOCKWISE UNTIL THE
OPERATOR RELEASES. WHEN TIGHTENING THE BYPASS VALVE IT MUST BE TIGHT IN
ORDER TO PREVENT FLUID OR PRESSURE ESCAPING BACK INTO THE CHAMBER.

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
9

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
10

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
11
MOUNTING DIMENSIONS
500A I/O SERIES GATE OPERATOR
USING A 2” GATE LEAF
INWARD SWING
DEGREE A B C
70 6 3 3
75 5-1/2 3-1/4 3
80 5 3-1/2 2-3/4
85 4-3/8 3-3/4 2-3/4
90 4 3-3/4 2-1/2
95* 3-3/4 3-5/8 2-1/4
100* 3-1/8 3-7/8 2-1/2
(*) THAT AN INSERT WILL HAVE TO BE USED IF THE HINGE POINT IS ON THE
CENTERLINE OF THE GATE POST. A MINIMUM OF 2” IS REQUIRED FROM THE
PROPERTY SIDE FACE OF THE GATE POST TO THE CENTER POINT OF THE REAR-
MOUNTING BRACKET.
OUTWARD SWING
DEGREE A B C
70 6 3-1/4 2-3/4
75 5-5/8 3-1/4 2-3/4
80 5-1/4 3-1/4 2-3/4
85 4-3/4 3-1/2 2-1/2
90 4-1/2 3-1/2 2-1/2
95 3-3/8 4 2-1/2
100 3-1/4 3-7/8 2-1/2
105 3 3-7/8 2-1/2

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
12
RECOMMENDED WIRE SIZES
HIGH VOLTAGE A.C.
14 AWG TO 400 FEET
12 AWG TO 650 FEET
10 AWG TO 1000 FEET
8 AWG TO 1650 FEET
6 AWG TO 2650 FEET
LOW VOLTAGE A.C.
18 AWG TO 100 FEET
16 AWG TO 170 FEET
14 AWG TO 270 FEET
12 AWG TO 430 FEET
10 AWG TO 690 FEET
8 AWG TO 1100 FEET
LOW VOLTAGE D.C.
20 AWG TO 400 FEET
18 AWG TO 700 FEET
16 AWG TO 1100 FEET
14 AWG TO 1700 FEET
12 AWG TO 2800 FEET
10 AWG TO 4500 FEET
NOTE: THESE WIRE SIZES ARE ONLY GENERAL RECOMMENDATIONS. FEDERAL, STATE
AND LOCAL CODES ALWAYS TAKE PRECEDENCE. CONSULT THE N.E.C. OR LOCAL
AUTHORITY HAVING JURISDICTION IF YOU HAVE WIRING CONCERNS.

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
13
G2M CONTROL BOARD DESCRIPTION
G2M-115V/220V SINGLE PHASE
MICRO CONTROLLED BOARD
THIS ELECTRONIC CONTROL UNIT IS SUITABLE FOR SINGLE-PHASE MOTORS, AND CAN
DRIVE UP TO TWO DIFFERENT MOTORS. THERE IS LEAF DELAY INCORPORATED WITH
THE USE OF A PLUG IN CARD. 9 DIP SWITCHES CAN SELECT SOME DIFFERENT OPTIONS
OF THE CONTROL UNIT.
THERE ARE THREE POSSIBLE TIMING POTENTIOMETERS: OPENING TIME, AUTOMATIC
CLOSING TIME, AND THE CLOSING TIME. A DIP SWITCH CAN DOUBLE THE OPENING AND
CLOSING TIME.
CHARACTERISTICS:
BUTTONS:
REVERSING BUTTON:
THE FIRST ACTIVATION WILL MAKE THE GATE OPERATE. THE SECOND ACTIVATION
WILL MAKE THE GATE STOP. THE THIRD ACTIVATION WILL REVERSE THE GATES
DIRECTION WHILE DIP SWITCH 2 IS ON. WITH DIP SWITCH 2 OFF ON THE CLOSE CYCLE,
THE GATE WILL AUTO REVERSE TO OPEN.
OPENING BUTTON:
USED ONLY TO OPEN AND HOLD OPEN THE GATE.

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
14
CLOSING BUTTON:
USED ONLY TO CLOSE THE GATE.
STOP BUTTON:
(NORMALLY CLOSE CONTACT), STOPS THE GATE IN OPENING/CLOSING.
THREE ADJUSTABLE TIMES
BLUE TIMER:
OPENING TIMER ONLY CONTROLS THE OPENING TIME BETWEEN 3 TO 30 SECONDS.
RED TIMER:
CLOSING TIMER ONLY CONTROLS THE CLOSE TIME BETWEEN 3 TO 30 SECONDS.
GREEN TIMER:
AUTOMATIC CLOSE TIMER WHEN THE GATE IS COMPLETELY OPEN THE TIMER IS
ACTIVATED AND WILL AUTOMATICALLY CLOSE AFTER THE PROGRAMMED TIME.
NOTE: BUILT IN 2 SEC. TIMER TO STOP GATE BEFORE REVERSING OPERATION OCCURS.
OPEN/CLOSE LIMIT SWITCHES;
THEY STOP THE OPENING AND/OR CLOSING OPERATION. MUST REMOVE THE TWO
JUMPER WIRES FROM TERMINAL 11 TO 12 AND 13 IF USED.
ENTRAPMENT SAFETY CONTACT:
IF ACTIVATED, THE RESULT IS REVERSING THE MOVEMENT IN BOTH OPENING AND
CLOSING FOR 2 SECONDS. THEN STOPS, IF THE SAFETY CONTACT IS STILL ACTIVE THE
ALARM WILL SOUND.
SAFETY REVERSING CONTACT:
THE RESULT IS REVERSING BACK TO OPEN WHILE THE GATE IS CLOSING, NOT ACTIVE
WHEN OPENING.
POWER OUTPUT:
YOU CAN CONNECT MOTORS UP TO HP
TIMER TABLE:
COLOR DESCRIPTION MINIMUM MAXIMUM
GREEN AUTOMATIC CLOSING TIME 1 SECOND 2 MINUTES
BLUE OPENING TIME 3 SECONDS 30 SECONDS
RED CLOSING TIME 3 SECONDS 30 SECONDS

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
15
DIP SWITCH ASSEMBLY OPERATION MODE SELECTION;
No. OPTION ON OFF
1 REVERSING STROKE FUNCTION
(OPERATOR FIRST WILL CLOSE FOR 1 SECOND)
ACTIVE INACTIVE
2 STEP-BY-STEP FUNCTION* ACTIVE INACTIVE
3 AUTOMATIC CLOSING FUNCTION ACTIVE INACTIVE
4 REVERSING BUTTON IS NOT
OPERATIVE DURING OPENING
ACTIVE INACTIVE
5 CLOSING ORDER BY CARS SAFETY CONTACT ACTIVE INACTIVE
6 SEE NOTE BELOW REF JP1 -------------- --------------
7 CARS SAFETY CONTACT IS
OPERATIVE DURING OPENING
ACTIVE INACTIVE
*STEP-BY-STEP IS THAT EACH ACTIVATION OF THE REVERSE BUTTON WILL STOP THE
GATE BEFORE CHANGING DIRECTION.
NOTE: THERE IS A JUMPER JP1 (BELOW THE REMOTE CONTROL CARD
CONNECTOR) THAT CAUSES THE SELECTABLE OPTION No. 6 IN THE FOLLOWING
MANNER:
JP1 OPEN:
No. 6 ON IN THE POWER ON STATE, UNIT WILL DO A CLOSING
FUNCTION.
OFF IN THE POWER ON STATE, UNIT WILL DO AN OPENING
FUNCTION.
JP1 CLOSED:
IN THE POWER ON STATE, THE DOOR REMAINS PAUSED. IN
THIS CASE, THE SWITCH No. 6 CONTROLS THE FUNCTION OF
THE TRAFFIC LIGHTS.
ON THE TRAFFIC LIGHTS CARD WILL ACT AS A FLASHING LIGHT
CARD (UPPER RELAY) AND A GARAGE LIGHT CARD (LOWER
RELAY).
OFF THE TRAFFIC LIGHTS CARD WILL ACT AS GREEN AND RED
LIGHTS.

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
16
SELECTABLE OPTIONS SWITCH S3
No. OPTION ON OFF
1 EXTENDS RUN
TIME
OPENING AND CLOSING
TIME (30 SECONDS TO 1
MINUTE)
OPENING AND CLOSING
TIME (3 SECONDS TO 30
SECONDS)
2 REPOSITIONING
THE DOOR *
ACTIVE INACTIVE
* WITH THIS OPTION ACTIVE AND THE DOOR CLOSED THE DOOR IS CLOSED FOR 2
SECONDS EVERY HOUR, AND IF THE DOOR IS OPENED THE DOOR IS OPENED FOR
2 SECONDS EVERY HOUR.
TERMINAL BOARD
POWER TERMINALS (FROM TOP TO BOTTOM)
1. POWER SUPPLY
2. POWER SUPPLY
3. OPEN MOTOR 1
4. CLOSE MOTOR 1
5. COMMON MOTOR 1
6. OPEN MOTOR 2
7. CLOSE MOTOR 2
8. COMMON MOTOR 2
ACCESSORY TERMINALS FROM LEFT TO RIGHT ARE AS FOLLOWS:
1. OUTPUT PEOPLE OR ANIMALS ALARM CONTACT (N/O)
2. OUTPUT PEOPLE OR ANIMALS ALARM CONTACT (N/O)
3. 24V AC @ 1 AMP MAX. (COMMON)
4. 24V AC @ 1 AMP MAX. (POWER)
5. OUTPUT ELECTRIC LOCK 12VDC @ 1 AMP MAX.
6. OUTPUT ELECTRIC LOCK 12VDC @ 1 AMP MAX.
7. INPUT RESET ALARM (N/O)
8. INPUT SAFETY PEOPLE OR ANIMALS (N/C)
9. COMMON FOR SAFETY
10. INPUT SAFETY CAR (N/C)
11. COMMON LIMIT SWITCH
12. INPUT OPEN LIMIT SWITCH (N/C)
13. INPUT CLOSE LIMIT SWITCH (N/C)
14. INPUT STOP BUTTON (N/C)
15. COMMON FOR STOP BUTTON
16. COMMON TO COMMAND BUTTONS
17. INPUT CLOSE BUTTON
18. INPUT OPEN BUTTON
19. INPUT REVERSING BUTTON

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
17
CONTROL CONTACT
TERMINAL DESCRIPTION
1ENTRAPMENT ALARM OUTPUT
2ENTRAPMENT ALARM OUTPUT
324VAC OUTPUT @ 1 AMP MAX.
424VAC OUTPUT @ 1 AMP MAX.
5ELECTRIC LOCK RELEASE 12VDC
6ELECTRIC LOCK RELEASE 12VDC
7ENTRAPMENT ALARM RESET
8ENTRAPMENT SAFETY CONTACT
9COMMON TO SAFETY CONTACT
10 REVERSING SAFETY CONTACT
11 COMMON TO LIMIT SWITCH
12 CLOSE LIMIT SWITCH
13 OPEN LIMIT SWITCH
14 STOP BUTTON
15 COMMON TO STOP BUTTON
16 COMMON TO CONTROL CONTACT
17 CLOSE COMMAND
18 OPEN COMMAND
19 REVERSE COMMAND

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
18
POWER & MOTOR CONNECTION
TERMINAL DESCRIPTION
1COMMERCIAL POWER SUPPLY 115V NEUTRAL (WHITE)
[220V LINE (BLACK)]
2COMMERCIAL POWER SUPPLY 115V LINE (BLACK)
[220V LINE (RED)]
3MOTOR # 1 CLOSE DIRECTIONAL (BLACK)
4MOTOR #1 OPEN DIRECTIONAL (BLACK
5MOTOR #1 COMMON (WHITE)
6MOTOR #2 CLOSE DIRECTIONAL (BLACK)
7MOTOR #2 OPEN DIRECTIONAL (RED)
8MOTOR #2 COMMON (WHITE)

BYAN SYSTEMS, INC.
Automatic Gate and Access Control Products
413 Linden • Lusk, WY 82225 • (800) 223-2926
19
SECOND MOTOR CARD T2M
CHARACTERISTICS:
THIS CARD IS SUITABLE FOR DRIVING A SECOND MOTOR THROUGH THE
CONTROL UNIT, SELECTING THE OPENING DELAY TIME AND THE CLOSING
DELAY TIME BETWEEN THE TWO MOTORS.
THE LIMIT SWITCHES OF THE SECOND MOTOR SHOULD BE CONNECTED TO THIS
CARD. THESE SIGNAL INPUTS ARE OPT-COUPLED TO PREVENT MALFUNCTION
DUE TO INTERFERENCE OR ATMOSPHERIC DISTURBANCES.
THE CONTROL UNIT POWERS THE CARD. THE CARD HAS TO BE INSERTED IN THE
CONNECTOR MARKED AS “T.2 MOTOR” ON THE MAIN BOARD OF THE CONTROL
UNIT.
IN THE OPENING OPERATION, MOTOR 1 ACTS FIRST AND IN THE CLOSING
OPERATION, MOTOR 2 ACTS FIRST.
ADJUSTABLE TIMERS:
DESCRIPTION MINIMUM MAXIMUM
LEFT (MOTOR 1) 0 SECONDS 15 SECONDS
RIGHT (MOTOR 2) 0 SECONDS 15 SECONDS
TERMINAL BOARD:
OPERATION TERMINALS: (FROM TOP TO BOTTOM).
3OPEN LIMIT SWITCH MOTOR 2 (NORMALLY CLOSED).
2CLOSE LIMIT SWITCH MOTOR 2 (NORMALLY CLOSED).
1COMMON LIMIT SWITCH MOTOR 2.
This manual suits for next models
1
Table of contents
Other Byan Gate Opener manuals
Popular Gate Opener manuals by other brands

Chamberlain
Chamberlain Elite RSL12V installation manual

CAME
CAME BX243C installation manual

Motorline professional
Motorline professional TELICA User's and installer's manual

Mirrow
Mirrow Moovo LN4 Series Installation and use instructions and warnings

Forematic
Forematic RETRO installation manual

Apollo
Apollo 7500ETL installation manual

Avidsen
Avidsen 114202 manual

MFZ Ovitor
MFZ Ovitor CS 300 operating instructions

Beninca
Beninca APPLE Series quick start guide

Chamberlain
Chamberlain LiftMaster Professional SL575 Installation

Forematic
Forematic RIO-R installation manual

Motorline
Motorline SP WING 400 Operating and installation instructions