C Prox Ltd DPS User manual

1
C Prox Ltd (inc Quantek)
59 Sheffield Road, Dronfield, S18 2GF
Standalone Keypad Access Control
DPS / DPS-W
User Manual
Please read the manual carefully before installing this unit

2
. Packing list
Name
Quantity
Remarks
Keypad
1
User manual
1
Screw driver
1
Φ20mm
×60mm,
s
pecial for keypad
Rubber plu
2
Φ6mm
×30 mm, used for fixin
Self tappin screws
2
Φ4mm
×28 mm, used for fixin
Star screws
1
Φ3mm
×6mm,
used for fixin
Please ensure that all the above contents are correct. If any are missin please notify us immediately
2. Quick reference programming guide
To enter pro rammin mode
.*. Master code .#.
999999 is the default master code
To exit pro rammin mode
.*.
Note that to undertake the following programming the master user must be logged in
To chan e the master code
0. .New code. .#. .New code. .#.
The master code can be 6 to 8 di its
To add a PIN user
.. .User ID number. .#. .PIN. .#.
The ID number is any number between 1 & 2000. The PIN is any four
di its between 0000 & 9999 with the exception of 1234 which is
reserved. Users can be added continuously without exitin
pro rammin mode.
To add a card user
.. .Read card. .#.
Cards can be added continuously without exitin pro rammin mode
To delete a PIN or card user
.2. .User ID number. .#.
for a PIN user or
.2. .Read card. .#.
for a card user
Users can be deleted continuously without exitin pro rammin
mode
To unlock the door for a PIN user
Enter the .PIN. then press .#.
To unlock the door for a card user
.Read valid card.
3. Description
The unit is a sin le door multifunction standalone access controller or a Wie and output keypad or card
reader. It is suitable for mountin either indoor or outdoor in harsh environments. It is housed in a stron ,
sturdy and vandal proof zinc alloy electroplated case. The DPS is for internal use, the DPS-W is for external
use as the electronics are fully potted so the unit is waterproof and conforms to IP68. This unit supports up
to 2000 users in either a card, 4 di it PIN, or a card + PIN option. The inbuilt card reader supports 125KHZ
EM cards. The unit has many extra features includin lock output current short circuit protection, Wie and
output, and a backlit keypad. These features make the unit an ideal choice for door access not only for
small shops and domestic households but also for commercial and industrial applications such as factories,
warehouses, laboratories, banks and prisons.

3
4. Features
•Waterproof, conforms to IP68 (DPS-W version only) •Adjustable door output, alarm and door open times
•Stron zinc alloy electroplated anti-vandal case •Very low power consumption (30mA)
•Full pro rammin from the keypad •Fast operatin speed, <20ms with 2000 users
•2000 users, supports card, PIN, or card + PIN •Lock output short circuit protection
•Can be used as a standalone keypad •Easy to install and pro ram
•Backlit keys •Built in LDR for anti-tamper
•Wie and 26 input for connection to external reader •Built in buzzer
•Wie and 26 output for connection to a controller •Red, yellow & reen LEDs display workin status
5. Specification
Operatin volta e 12-24Vdc
User capacity 2000
Card readin distance 3-6 cm
Active current <60 mA
Idle current 25±5 mA
Lock output load Max 3A
Alarm output load Max 20A
Operatin temperature -45 to 60⁰C
Operatin humidity 10% to 90% RH
Waterproof DPS – internal use. DPS-W – conforms to IP68
Adjustable door relay time 0-99 seconds
Adjustable alarm time 0-3 minutes
Wie and interface Wie and 26 bit
Wirin connections Electric lock, exit button, external alarm
6. Installation
•Remove the back cover from the keypad usin the supplied special screw driver.
•Mark and drill two holes on the wall for the self-tappin fixin screws and one for the cable.
•Put the two wall plu s into the fixin holes.
•Fix the back cover firmly on the wall with the two self-tappin screws.
•Thread the cable throu h the cable hole.
•Attach the keypad to the back cover.

4
7. Wiring
Colour Function Description
Pink BELL_A Doorbell button one end
Pink BELL_B Doorbell button to the other end
Green D0 WG output D0
White D1 WG output D1
Grey ALARM Alarm ne ative (alarm positive connected to 12/24V+)
Yellow OPEN Exit button one end (the other end connected to GND)
Brown D_IN Ma netic switch one end (the other end connected to GND)
Red 12/24V + 12/24V + DC re ulated power input
Black GND 12/24V – DC re ulated power input
Blue NO Relay normally open
Purple COM Relay common
Oran e NC Relay normally closed
Common power
supply dia ram
Special power
supply dia ram

5
8. To reset to factory default
a. Disconnect power from the unit.
b. Press and hold the # key whilst powerin the unit back up.
c. On hearin the two “Di” sounds, release the # key, system is now back to factory settin s.
Please note only installer data is restored, user data will not be affected.
9. Anti- tamper alarm
The unit uses an LDR (li ht dependent resistor) as an anti-tamper alarm. If the keypad is removed from the
cover then the alarm will operate.
0. Sound and light indication
Operation Status Red Light Green Light Yellow Light Buzzer
Power on - Bri ht - Di
Stand by Flashin - - -
Press keypad - - - Di
Operation successful - Bri ht - Di
Operation failed - - - DiDiDi
Enter into pro rammin mode
Solid - -
-
In the pro rammin mode - - Solid Di
Exit from the pro rammin Bri ht - - Di
Open the door - Solid - Di
Alarm Flashin - - Alarm
. Detailed programming guide
. User settings
To enter pro rammin mode
.*. Master code .#.
999999 is the default master code
To exit pro rammin mode
.*.
Note that to undertake the following programming the master user must be logged in
To chan e the master code
.0. .New code. .#. .New code. .#.
The master code can be 6 to 8 di its
Setting the working mode:
Set valid card users only
Set valid card and PIN users
Set valid card or PIN users
.3. .0. .#.
Entry is by card only
.3. .. .#.
Entry is by card and PIN to ether
.3. .2. .#.
Entry is by either card or PIN (default)

6
To add a user in either card or PIN mode, i.e. in the .3. .2. .#. mode. (Default setting).
To add a PIN user
.. .User ID number. .#. .PIN. .#.
The ID number is any number between 1 & 2000. The PIN is any four di its
between 0000 & 9999 with the exception of 1234 which is reserved. Users
can be added continuously without exitin pro rammin mode as follows:
.. .User ID No . .#. .PIN. .#. .User ID No2. .#. .PIN. .#. ….
To delete a PIN user
.2. .User ID number. .#.
Users can be deleted continuously without exitin pro rammin mode
To chan e the PIN of a PIN user
(This step must be done out of pro rammin
mode)
.*. .ID number. .#. .Old PIN. .#. .New Pin. .#. .New Pin. .#.
To add a card user (method 1)
This is the fastest way to enter cards, user ID
number auto eneration.
.. .Read card. .#.
Cards can be added continuously without exitin pro rammin mode
To add a card user (method 2)
This is the alternative way to enter cards usin
User ID allocation. In this method, a User ID is
allocated to a card. Only one User ID can be
allocated to a sin le card.
.. .User ID number. .#. .Read card. .#.
Users can be added continuously without exitin pro rammin mode
To add a card user (method 3)
Add by the number on the card. Card number is
the last 8 di its printed on the back of the card.
User ID number auto eneration.
.. .Card number. .#.
Users can be added continuously without exitin pro rammin mode
To add a card user (method 4)
In this method, a User ID is allocated to a card
number. Only one User ID can be allocated to
the card number.
.. .ID number. .#. .Card number. .#.
Users can be added continuously without exitin pro rammin mode
To delete a card user (method 1)
This method uses the card itself that needs to
be deleted.
.2. .Read card. .#.
Users can be deleted continuously without exitin pro rammin mode
To delete a card user (method 2)
This method is for deletin users by User ID
number. This operation can be used when the
user has lost their card.
.2. .User ID number. .#.
Users can be deleted continuously without exitin pro rammin mode
To delete a card user (method 3)
This option is for deletin users by card
number. This operation can be used when the
user has lost their card.
.2. .Card number. .#.
Users can be deleted continuously without exitin pro rammin mode
To add a card and PIN user in card and PIN mode ( .3. .. .#. ) mode.
To add a card and PIN user
The PIN is any 4 di its between 0000 & 9999
with the exception of 1234 which is reserved.
Add the card user as for a card user
Press .*. to exit from pro rammin mode, then allocate the card a PIN as
follows:
.*. .Read card. .1234. .#. .PIN. .#. .PIN. .#.

7
.2 Door settings
Relay output delay time
To set door relay strike time
.*. .Master code. .#. .4. .0 – 99. .#. .*.
0 – 99 is to set the door relay time to 0 – 99 seconds
Door open detection
Door open too lon (DOTL) warnin . When used with an optional ma netic contact or a ma netic lock with a built-in contact,
if the door is opened normally, but not closed after one minute, the inside buzzer will beep automatically to remind people to
close the door and continue for one minute before switchin off automatically.
Door forced open warnin . When used with an optional ma netic contact or a ma netic lock with a built-in contact, if the
door is forced open, or if the door is opened after 20 seconds, the inside buzzer and alarm output will both operate. The
alarm output time is adjustable between 0 – 3 minutes, with the default bein 1 minute.
To disable door open detection (factory
default)
.6. .0. .#.
To enable door open detection
.6. . . .#.
To chan e a PIN in card and PIN mode
(method 1)
Chan e usin card. Note that this is done
outside of pro rammin mode so the user can
undertake this themselves.
.*. .Read card. .Old PIN. .#. .New PIN. .#. .New PIN. .#.
To chan e a PIN in card and PIN mode
(method 2)
Chan e usin User ID number. Note that this is
done outside of pro rammin mode so the user
can undertake this themselves.
.*. .ID number. .#. .Old PIN. .#. .New PIN. .#. .New PIN. .#.
To delete card and PIN user
To delete the user just delete the card
.2. .User ID number. .#.
To add a card user in card mode ( .3. .0. .#. ) mode.
To add or delete a card user
The operatin is the same as addin and deletin a card user in
.3. .0. .#.
To delete all users
To delete all users
Please note this is a dan erous operation, use
with care
.2. .0000. .#.
To unlock the door
For a PIN user
Enter the .PIN. then press .#.
For a card user
.Read card.
For a card and PIN user
.Read card. then enter .PIN. .#.

8
2. The unit operating as a Wiegand output reader
In this mode the unit supports a Wie and 26 bit output so the Wie and data lines can be connected to any
controller which supports Wie and 26 bit input.
Alarm output time
To set the alarm output time (0-3
minutes). Factory default 1 minute
.5. .0 – 3. .#.
Keypad lockout & alarm output options
If there are 10 invalid cards or 10 incorrect PIN’s entered in a 10 minute period, either the keypad will lockout for 10 minutes
or both the alarm and inside buzzer will operate for 10 minutes, dependin on the option selected below.
Normal status: No keypad lockout or
alarm (factory default)
.7. .0. .#.
(Factory default)
Keypad lockout
.7. . . .#.
Alarm and inside buzzer operation
.7. .2. .#.
To turn off the alarm
To reset the door forced open alarm
.Read valid card. or .Master code. .#.
To reset the door open too lon alarm
Close the door or .Read valid card. or .Master code. .#.

9
Issue record
Site: Door location:
User ID No User name PIN Card number Issue date
0001