Lazerpoint™ CM-TXLF Series
FOB Style Transmitters
INSTALLATION INSTRUCTIONS
Door Activation Devices
1. GENERAL DESCRIPTION
Camden Lazerpoint™ Radio Controls comprise the following
models:
• CM-TXLF-1, CM-TXLF-2, CM-TXLF-4, CM-TXLF-1LP and
CM-TXLF-2LP Key Fob Transmitters, as well as;
• CM-TX-9 Wall switch ready transmitter
• CM-TX-99 Plug-in 2-Channel Transmitter
• CM-RX-91 Basic Receiver
• CM-RX-92 Full function (dual relay) Receiver.
These instructions cover the TXLF transmitters.
Camden Key Fob transmitters utilize readily available CR-2032
Lithium batteries, and special circuitry to assure long life. A
proprietary bi-colour LED circuit is used to annunciate wireless
activation, low battery, & Battery Gas Gauge™ conditions.
2. SPECIFICATIONS
Models
TXLF-1 (FVIN: 3A)
TXLF-2 (FVIN: 3B)
TXLF-4 (FVIN: 3C)
Buttons / Channels 1, 2, & 4 respectively
Frequency Operates in the 902 – 928
MHz ISM Band
Codes 1 million (20 bit) codes
LED Indicator
Used for transmit status (green),
Low Battery, and Battery Gas
Gauge™ indicator (red).
Power 1 x CR-2032 Lithium battery
Battery Life Minimum 115,000 operations
Range Over 250 ft (76 m) open area
Temperature Rating -40°F to 185°F (-40°C to +85°C)
Dimension 2 9/16” L x 1 9/16” W x 5/8” D
(102mm x 42mm x 16mm)
2. INSTALLATION
Mounting
Camden TXLF Fobs can be attached to a key chain using the
included ring.
Fobs can also be mounted to a wheelchair by using accessory
number # CM-TXLFB Mounting Base. This unique accessory
converts any of the Mini Fobs to a full size unit which may be
clipped to a belt or sun-visor, or fastened to a desk or counter
for reception use. See our Lazerpoint™ spec sheet or TXLFB
Instruction manual for further details.
The CR-2032 battery is pre-installed in the Fob. Simply press
the button and observe the GREEN LED, which indicates proper
transmission.
Test the battery strength by pressing and holding the button
for approximately 5 seconds. The LED should ash RED 5
times, meaning the battery is at full capacity. This is the Battery
Gas Gauge™ feature. If the LED ashes RED only 1 - 2 times,
you should change the battery for a fresh (new) one. See
instructions at right.
When the battery is low and needs to be changed, the LED will
indicate a slow red ash — 1 ash per second. The unit will still
continue to function (transmit) for a time, but the battery should
be changed as soon as possible.
Learning the Transmitter(s) to the Receiver
To learn the transmitter into an RX-91 or RX-92 receiver, press
the PB1 (or PB2) button on the Receiver using a small blunt
object such as a small blade screwdriver or similar. Within 10
seconds, press the button on the TXLF transmitter. The Green
LED Array will ash once to conrm enrollment. Repeat
withanyadditionaltransmitters. Pressingthe learned transmitter
again will signal the receiver that you are nished programming
and LED’s 1 & 2 will ash, in an alternating sequence.
Pressing the transmitter a third time will activate the relay and
corresponding LED, and also the device connected to the relay
contacts.
For multiple button FOBS – TXLF-2 & TXLF-4, learn the desired
button into one receiver, and the other button(s) into additional
receivers. (You could also learn Button 1 into Channel 1 of
the RX-92, and Button 2 into Channel 2 of the same RX-92.)
Refer to the RX-91 or RX-92 receiver for further programming
instructions.
Page 2 of 3
LAZERPOINT™ CM-TXLF SERIES FOB STYLE TRANSMITTERS
INSTALLATION INSTRUCTIONS
Replacing the Battery
4. WARRANTY
Camden Door Controls guarantees the CM TXLF series
transmitters to be free from manufacturing defects for 3 years
from date of sale. If during the rst 3 years a TXLF transmitter
fails to perform correctly, it may be returned to our factory
where it will be repaired or replaced (at our discretion) without
charge. Except as stated herein, Camden extends no warranties
expressed or implied regarding function, performance or
service.
Batteries are exempt from this warranty.
Assembly Instructions
Camden
PWA-201-0329-051
Camden
PWA-201-0329-051
Camden
PWA-201-0329-051
+
Panasonic
CR2032
3V
+
Camden
PWA-201-0329-051
Panasonic
CR2032
3V
+
1
4 5
6
7
2 3
Twist a coin in slot to
open transmitter case
Turn over the PCB
Separate 2 halves
Remove old battery
Insert new battery
Remove PCB from
bottom half
Insert PCB. Snap
the case together.
PWA-201-0329-051
Camden
Plastic
Case FOB
Top
Assembly
Top + Bottom
Assemblies
Snap Together
Bottom
Assembly
Plastic Case
Bottom
Plastic
Buttons
Translucent
Rubber
Membrane
Circuit
Board
Call: 1.877.226.3369 / 905.366.3377
Visit: www.camdencontrols.com
Opening New Doors to
Innovation, Quality and Support!
Page 3 of 3
LAZERPOINT™ CM-TXLF SERIES FOB STYLE TRANSMITTERS
INSTALLATION INSTRUCTIONS
IC & FCC INFORMATION FOR USERS
IC: 8725A-TXLF
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions
suivantes :
1) l’appareil ne doit pas produire de brouillage;
2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
FCC ID: 2AHAB-TXLF
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
Changes or modications made to this equipment not expressly approved by Camden Door Controls could void the user’s authority to operate the equipment.
File: CM-TXLF Transmitter
Manual.indd- Rev.6
Revised: 11/01/2019
Part No: 40-82B160

This manual suits for next models

3

Other CAMDEN Door Opening System manuals

CAMDEN CX-DE-502SO User manual

CAMDEN

CAMDEN CX-DE-502SO User manual

CAMDEN CM-SRX2 User manual

CAMDEN

CAMDEN CM-SRX2 User manual

CAMDEN CM-550SK-V2 User manual

CAMDEN

CAMDEN CM-550SK-V2 User manual

CAMDEN CX-95S-DH User manual

CAMDEN

CAMDEN CX-95S-DH User manual

CAMDEN CX-ED1959 User manual

CAMDEN

CAMDEN CX-ED1959 User manual

CAMDEN CM-47-ADP1 User manual

CAMDEN

CAMDEN CM-47-ADP1 User manual

CAMDEN CM-300 User manual

CAMDEN

CAMDEN CM-300 User manual

CAMDEN CM-300 User manual

CAMDEN

CAMDEN CM-300 User manual

CAMDEN CM-SRFM2 Kit User manual

CAMDEN

CAMDEN CM-SRFM2 Kit User manual

Popular Door Opening System manuals by other brands

Hard Head 316-414 User instructions

Hard Head

Hard Head 316-414 User instructions

Label NEXT 120s installation manual

Label

Label NEXT 120s installation manual

Abus PR2700 Fitting and operating instructions

Abus

Abus PR2700 Fitting and operating instructions

Label NEPTIS/LE installation manual

Label

Label NEPTIS/LE installation manual

Label ETERNA 90 EASY installation manual

Label

Label ETERNA 90 EASY installation manual

Entrematic Ditec LOKSB installation manual

Entrematic

Entrematic Ditec LOKSB installation manual

Nice SUMO Instructions and warnings for the fitter

Nice

Nice SUMO Instructions and warnings for the fitter

Optex OA-AXIS I manual

Optex

Optex OA-AXIS I manual

Dorma TS 68 manual

Dorma

Dorma TS 68 manual

CDVI DIGIWAY PLUS manual

CDVI

CDVI DIGIWAY PLUS manual

Assa Abloy Corbin Russwin PED159 installation instructions

Assa Abloy

Assa Abloy Corbin Russwin PED159 installation instructions

Autoslide AutoSwing ASW8-1 installation manual

Autoslide

Autoslide AutoSwing ASW8-1 installation manual

Ribind UP manual

Ribind

Ribind UP manual

CAME C-BX installation manual

CAME

CAME C-BX installation manual

GEZE TS4000 installation instructions

GEZE

GEZE TS4000 installation instructions

Tormax TTXII Installation and operating manual

Tormax

Tormax TTXII Installation and operating manual

TdA PE200B Installation and user manual

TdA

TdA PE200B Installation and user manual

CDV Group DIGIWay DWS102 Series Use and installation  manual

CDV Group

CDV Group DIGIWay DWS102 Series Use and installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.