Camfil CITY S User manual

CITY S, CITY M
AIR PURIFIERS
USER GUIDE

Camfil – Clean Air Solutions 32 Camfil – Clean Air Solutions
CONTENT
1Purpose 3
2 Contents 3
3 Version history 4
4 Identification plate 4
5 Guarantees and undertakings 4
6Preface 4
7Technical specifications 4
8Fan specifications 5
9 Air flow 5
10 Use 5
11 Safety instructions 6/7
12 Design 7
13 Constituent standard components 7
14 Transport and unpacking 7
15 Air flow details 8
16 Taking into operation 8/9
17 Positioning 9
18 Electrical connection 9
19 Product and the environment 10
20 Filters and the environment 10
21 Maintenance 10
22 Instructions for replacing filters 10
23 Filter replacement 11
24 EU provisions governing the product 12
25 Camfil IAQ analysis 15
1 PURPOSE
This technical manual is part of the documentation that must be available under appendix 5 of
the machine directive. The purpose of the manual is to give details of the units design and how it
works. New users must be able to work safely with this product. Web: www.camfil.com
2 CONTENTS
This manual gives details of the product and must not be used for any other machine. Besides
short explanations of what the machine is used for, the first few sections also give some technical
specifications. After these, there are illustrated texts about the various parts that make up this
product. The user manual also includes details of safety procedures associated with the use of
the machine.

Camfil – Clean Air Solutions 54 Camfil – Clean Air Solutions
3 VERSION HISTORY
Version Date Signature Altered
001 See approval Initial version
4 IDENTIFICATION PLATE
All Camfil City S and City M air purifiers have the identification plate at the power supply to the unit.
5 GUARANTEES AND UNDERTAKINGS
The guarantee relates to full functionality as per the details in this User Manual and covers errors
in software and hardware for a period of one year from the delivery date. Should the equipment
develop a fault, please contact your distributor.
Distributor:
Camfil Svenska AB
Industrigatan 3
SE-619 33 TROSA
Tel: +46 (0)156 537 00
Web: www.camfil.com
6 PREFACE
Thank you for buying a high quality air purifier from Camfil. We hope that you will be delighted with
the use of your Camfil air purifier.
IMPORTANT!
Before using your high quality air purifier, it is important that you, as the user:
1) read this User Manual
2) read the fan instructions
3) follow the safety instructions in both documents.
7 TECHNICAL SPECIFICATIONS
External dimensions, vertical model
City S City M
Height (mm) 465 720
Width (mm) 340 340
Depth (mm) 345 345
Weight (kg) 12.0 (including new filters) 16.0 (including new filters)
Filter weight (kg) 2.0 kg (2 filters are needed) 4.3 kg (2 filters are needed)
8 FAN SPECIFICATIONS
Phase 1~
Nominal voltage VAC 230
Nominal voltage range VAC 200 .. 240
Frequency Hz 50/60
Type of data definition ml
Speed min~1 3200
Power input W 83
Current draw A 0.75
Min. ambient temperature ºC -25
Max. ambient temperature ºC +60
ml=max.load; subject to alterations
9 AIR FLOW
With filter H13 with odour, VOC & ozone removal
City S City M
Step Qv
[m3/h]
N
[rpm]
Pe
[W]
LpA
[dBA]
Qv
[m3/h]
N
[rpm]
Pe
[W]
LpA
[dBA]
121 561 5 20.7 37 520 4 15.5
247 865 6 28.3 67 728 5 15.5
382 1168 9 35.8 94 907 6 15.5
4119 1428 12 40.2 127 1072 7 21.7
5183 1866 22 44.9 251 1772 19 37.7
6 Max. 247 2267 36 51.9 433 2733 55 52.6
10 USE
The air purifier is used to clean indoor air by mechanically filtering, through highly efficient
filters. Development of the system is primary for expert users and installation companies for
offices, hospitals and schools.

Camfil – Clean Air Solutions 76 Camfil – Clean Air Solutions
11 SAFETY INSTRUCTIONS
Read the technical manual and follow the instructions. The machine’s power supply has to be
disconnected during installation, servicing, maintenance and filter replacement.
CAUTION: Pull out the electrical connector or use the safety switch when working on the
product.The machine is not to be regarded as de-energised until 5 minutes after disconnection
from the power supply.
Rotating parts do not stop immediately once power has been cut or the machine has been switched
off. Allow 5 minutes to elapse before handling the cabinet.
1. In its standard version, this product must only be used for handling dry non-explosive
materials. If the air purifier is used for purposes other than those set out in the technical
Manual, or is handled otherwise than set out therein, Camfil AB can accept no liability
whatsoever for the consequences of said use/handling.
2. NOTE: Fixed installation may only be carried out by a professional with the appropriate
qualifications who takes responsibility for the installation.
3. The machine must NOT be used in ATEX classified areas or where explosive gases may be
present at any time.
4. Electrical connection may only be carried out by an appropriately qualified electrician.
5. All accessories, filters, spare parts, etc. used, must be approved by Camfil. Guarantee
undertakings cease to apply if the foregoing is not respected. Please contact Camfil for the
correct accessories.
6. Do not cover inlets or outlets.
7. Inserting objects through inlets or outlets is forbidden.
8. The unit must not be used in environments where burning / smouldering objects can get
into the machine.
9. The unit must be used indoors only.
10.The unit must be used in the -25˚C – +60˚C temperature range only.
11.The unit must not be drenched with water. The highest permitted humidity is 85% if a carbon
filter is used.
12.Follow the filter handling and replacement instructions very carefully. Incorrect handling can
damage the filter medium and the guaranteed filter class will not be achieved as a result.
13.Take great care when handling used filters. Incorrect handling can result in ill health or
sickness. Follow the instructions for filter replacement.
14.This unit can be used by children aged 8 years and above and persons with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, if they have been given
supervision or instruction concerning the safe use of the equipment and understand the
resulting dangers, Children should not play with the device. Cleaning and user maintenance
should not be performed by children without supervision.
12 DESIGN
The unit is a self-standing one-section design housing the filters, fan section and all electrical
connections. The machine is entirely constructed of aluminium and plastic parts and is therefore
environmentally friendly and recyclable.
13 CONSTITUENT STANDARD COMPONENTS
In its standard version, the air purifier is supplied with the following components:
One City S or City M unit
Filters for the chosen purpose
Quick guide
Technical Manual.
Fan instructions (from the fan supplier)
Electrical connector
If anything is missing, or if you require further information about accessories, please
contact Camfil.
14 TRANSPORT AND UNPACKING
Remove the packaging carefully. If sharp objects are used to unpack the product, be careful not to
damage the machine’s cables and design finish. Take special care when handling the filters. See
the filter replacement section.
Check that the product has not been damaged during transport. Report any transport damage to
the carrier. Check also that the delivery is complete.

Camfil – Clean Air Solutions 98 Camfil – Clean Air Solutions
15 AIR FLOW DETAILS
16 TAKING INTO OPERATION
First, read the entire Technical Manual.
Only appropriately qualified electricians may carry out work with electrical connections. You
must be able to turn off the power supply without touching the unit.
Connect the air purifier to the electrical outlet. Ensure that there is nothing obstructing the air
outlets / inlets (see figure below how to operate).
Controller card description
• Press + (plus) to increase the airflow (the blue led indicators will guide you to what
airflow you have chosen)
• Press – (minus) to lower the airflow
• A red warning light will be lit at the filter change symbol, when it’s time for filter
replacement.
• When the red warning light have been lit and filter are replaced you need to calibrate
the unit by pressing + and- at the same time during 5 seconds. Now you are secured that
the warning light will be lit again when it’s time for filter replacement.
• On the back side of the unit is the electrical connector with fuse holder and machine plate.
17 POSITIONING
The unit must always be positioned and used indoors only. Air outlets and intakes must not be
obstructed during use. Before putting the air purifier in operation, ensure there is sufficient space
(10 cm) around the outlet and inlet.
18 ELECTRICAL CONNECTION
Electrical connection must be carried out by an appropriately qualified electrician. All routing of
cables, etc., must be carried out in accordance with the relevant regulations. The unit comes from
the factory ready for plugging in. Any alterations to the machine’s internal electrical systems must
only be carried out by appropriately qualified persons using equipment supplied by Camfil.
The unit must only be connected to the network voltage stated on the machine plate (identification
plate).
Dirty air
Clean air
Filters
Fan

Camfil – Clean Air Solutions 1110 Camfil – Clean Air Solutions
5. Grip the handle on top of the filter and
pull it towards you. Put the filter in a
plastic bag. Do the same procedure on
the other filter and put it in a plastic bag.
6. Take a new HEPA filter out of its box.
NB! Do not touch the filter’s surface.
Hold the handle only!
Put the filter in its positioning press it
down and against the pattern of holes.
The black gasket must be towards the
hole pattern of the unit.
Do steps 1- 6 in reverse order.
1. Switch off the unit by turning the safety
switch or remove the electrical connec
tor. Make sure that the blue operating
LED’s is off.
2. Lift of the top cover of the unit
3. Push the two buttons and lift up the hatch.
4. Take a firm grip on the pull the hatch
upwards.
19 PRODUCT AND THE ENVIRONMENT
The air purifier is made from lead-free components. It can be recycled. Used models must always
be sent to a recycling station for correct recycling and/or disposal of parts and components.
20 FILTERS AND THE ENVIRONMENT
Note that filters must not be disposed of along with ordinary household waste. Scrapped filters
must always be correctly taken care of and handled safely. Recycling or disposal must always be
carried out at an approved waste facility. If you have any questions about this, please contact your
local authority or distributor for advice on correct care.
21 MAINTENANCE
If necessary, the unit can be cleaned using a mild cleaning agent.
Before cleaning, always switch off the machine and pull out the electrical connector!
22 INSTRUCTIONS FOR REPLACING FILTERS
WARNING! When handling used filters, personal protective equipment such as protective gloves
and masks must be used. To choose the correct type of respiratory protection, consult either the
safety representative / officer at your workplace or the manufacturer of the respiratory protection.
Used filters may contain harmful substances and particles. With incorrect handling, these can
escape to the environment and present risks of sickness and ill health.
Filters should be replaced on a continuous basis. See Camfil AB’s recommendations concerning
the frequency of filter replacements.
23 FILTER REPLACEMENT
Always use protective gloves and respiratory protection when handling used filters!
Risk of ill health and sickness.

Camfil – Clean Air Solutions 1312 Camfil – Clean Air Solutions
24 EU PROVISIONS GOVERNING THE PRODUCT
This product complies with EU standards as per the “Machinery Directive” (2006/42/EC), the
“Low Voltage Directive” (2006/95/EC) and the “EMC Directive” (2004/108/EC).
Note that correct observance of the installation and safety instructions is a precondition for
the compliance of all operating properties. For more details of technical specifications, the
standards that have been complied with and Camfil’s patents, please contact Camfil.

Camfil – Clean Air Solutions 1514 Camfil – Clean Air Solutions
25 CAMFIL IAQ ANALYSIS –
MONITORS AND MEASURES YOUR AIR QUALITY IN REAL TIME
IAQ stands for Indoor Air Quality and is a measurement of the quality of indoor air. As an addi-
tional option for your CamCleaner system, you can choose Camfil IAQ Analysis, which provides a
direct picture of the air quality in your rooms.
We monitor the air quality and all measurements are saved in an IAQ database containing mil-
lions of measurement values and benchmarks for the indoor environment and air quality.
As a customer, you have the option to view the analysis in real time at the time of measuring,
and all measurements can easily be compared with one another. A calibrated particle counter
can be used to examine the quantity of particles in the air. By subscribing to this service, you, as
our customer, will always have a particle counter on location that is connected to a computer
monitoring the indoor environment.
When an abnormal particle distribution is identified, or in cases of other suspected problems, we
perform an analysis with a scanning electron microscope (SEM) with associated X-ray analysis
system (EDAX). As required, the quantity, weight and structure of the particles are analyzed, as
well as the chemical composition of the air and element content. We have more than 10 years of
experience from these analyses. We also work together with many of the world’s leading labo-
ratories for further analysis. Our IAQ reports are based on the following standards for air clas-
sification: SS EN, SS EN ISO and IEST.

CAMFIL is the world leader in air
filters and clean air solutions.
Camfil is the global industry leader in clean air solutions
with 50+ years of experience. Our solutions protect people,
processes and the environment to benefit human health,
increase performance, and reduce and manage energy
consumption. Twenty-five manufacturing plants, six R&D
sites and over 65 local sales offices worldwide provide
service and support to our customers. The Camfil Group is
headquartered in Sweden but more than 95% of sales are
international. The Group has around 3,800 employees and
sales more than SEK 6.0 billion.
www.camfil.com
This manual suits for next models
1
Table of contents
Other Camfil Air Cleaner manuals
Popular Air Cleaner manuals by other brands

Aztech
Aztech e-Nano MT400 user manual

Holmes
Holmes Harmony HAP615 owner's guide

Seeley
Seeley Braemar RPCQi Series installation manual

Surgically Clean Air
Surgically Clean Air JADE2.0 Operation manual

Muonio
Muonio UV-L 110 installation manual

C+R Automations
C+R Automations LUDES AIR 270 Assembly and operation instructions