Camfil City Touch User manual

Air Purifier
User Manual
City Touch

User Manual
Contents
Part name and specifications
Operating Instructions
Control panel
Control panel / Maintenance
Clean and replace the filters
Normal Problems
Safety Instruction
Contents
Purpose
Content
The product information provided by this user manual is only applicable to City Touch.In this
manual, the first part describes the specific product parameters.
Next is the operation guide and instructions for filter replacement.
The Purpose of this user manual is to explain the functions of the City Touch to ensure the user
can operate the unit safely and efficiently and receive the best possible results.
1
2
4
6
7
8
9
10
Touch

User Manual
Camfil – Clean Air Solutions 2
Part name and specifications
Air Purifier Body
Final Filter
VOC Filter
PRE Filter
Filter Cover
500m3/ hModel
Products
Power Supply Standby power
Power
consumption
Weight
Clean Air Delivery
Rate(CADR):(m3/h)
Applicable area
System structure
Intelligent
mode
Air quality
sensor
Yes VOC sensor / particulate sensor
AC 220-240V 50Hz
City Touch
Camfil Air Purifier
Dimensions (mm) 340(W)x496(H)x388(D) 8.2Kg
40W
0.5W
35~60m2
Parallel double inlet mechanical
dust collection
Touch

User Manual
Camfil – Clean Air Solutions 3
Operating Instructions
Working instructions
Ensure the plastic bags of the filters on BOTH SIDES are removed, before plugging in the air purifier
for the first time.
Turn on the power and shut down
Press ( ) key to start up, the power indicator and the LED indicator will light up, the air purifier will
make two "Beep" sounds synchronously. The City Touch will start up on medium level the first time
you turn it on. Everytime you switch on after the first time, the unit will start up at whatever level you
left it at previously,the sensor is powered up. Press ( ), the machine will get into standby state
after it makes a long "Beep" sound.
Plug in operation
Plug in the power, it will make a "Beep" sound, the green, yellow and red lights of the air quality
indicator will light up and go out in turn, then other indicators and LED button will light up from left to
right until they are all lit, and then go out in turn. All the LED lights on the panel off , the machine
goes into standby mode.
Air quality indicator
Air quality indicator according to the sensor detection results can be displayed as:
Green: good air quality Yellow: normal air quality Red: poor air quality
The sensor will be preheating in the first 3 minutes after you turn the power on.
Please note that the sensor may have deviation if it becomes dirty - to avoid this please clean the
sensor regularly.
Auto mode
The air purifier will control the fan motor according to the air quality detected by the sensor.
a. Good air quality,the unit will run at setting 2, dropping to setting 1 every 3 minutes.
b. Fair air quality, the unit will run at setting 3, dropping to setting 2 every 3 minutes.
c. Poor air quality, the unit will run at setting 4, dropping to setting 3 every 3 minutes.
Sleep mode
Press mode ( ) to select the sleep mode. The air purifier will operate at the setting 1, after 3
seconds the air quality indication lights and other indicator lights will go out, only SLEEP, ( )and
mode ( ) (brightness halved) remain. To cancel the sleep mode, press mode ( ) or Speed
( ) to change the speed setting.
Airflow Volume selection
Either mode ( ) or Speed ( ) key can be used for air volume switching, mode ( ) key can
switch between AUTO-SLEEP-QUICK.
Touch

User Manual
Camfil – Clean Air Solutions 4
Operating Instructions
QUICK mode
The fan motor runs circularly by Turbo setting 4-3 every 1 minute and the LED light changes
synchronously, after 30 minutes the fan switches to AUTO mode and AUTO LED lights up synchronous-
ly. Speed ( ) key can switch speed 1-4 (from low to high) to TURBO.
Filter replacement reset.
PRE filter cleaning/ VOC filter replacement/ FINAL filter replacement
Filter timing reset: passive reset and active reset.
In the normal operation, the filter replacement indicator is turned off. When you accidentally turn on a
light, It will turn off automatically after 5 seconds. Or press ( ) to switch into the three lights off, it
will not affect the timing.
Passive reset: When the machine detects that the filter needs to be cleaned or replaced, The filter LED
will blink continuously to remind users to clean or replace the filter. After users clean or replace the
filter , press ( ) key to switch to the specified filter, activating the corresponding indicator light for
constant brightness. Then press the ( ) key again 3 seconds to reset the timer. If users don’t reset,
LED blinks continuously after 5 seconds.
Active reset: If users think the filter is dirty and want to replace it in advance. Press ( ) key to select
the filter which you want to replace (the filter indicator lights up), press ( ) key for 3 seconds to
reset the timer after replacing filter.
Intensity control
Press ( ) key to set the brightness of the LED in the state of power-on. The setting value is
permanent memory. It still remembers the last brightness when you restart.
4 grades: ( ) high brightness →( ) normal brightness ( initial value ) →( ) half brightness →
off (air quality lights off, logo LED off, the remaining panel lights are halved in brightness).
Child lock
Press ( ) key for 3 seconds in the state of power-on to open the child lock function. Press the ( )
button for 3 seconds again to unlock the child lock. In the child lock state, only press the ( ) for 3
seconds to unlock, the other key operations are invalid.
Timer setting
Press TIMER ( ) key for regular shutdown, you can set automatic shutdown at 2H, 4H, 8H, 10H,
12H. If the indicator goes out, then the timer setting is cancelled.
Touch

Camfil – Clean Air Solutions 5
User Manual
Control panel
QUICK
SLEEP
TURBO
FINAL
AUTO
4
3
2
1
12H
10H
8H
4H
2H
VOC
PRE
CVM 051L
City Touch
54321 6
10987
Child Lock
Power
Mode
Speed
Timer
Filter Reset
Intensity
2 6
3
4
51
Air quality indicator
8
Filter replacement indicator
FINAL
VOC
PRE
Intensity control indicator
10
9
7
Touch

Camfil – Clean Air Solutions 6
User Manual
Remote Control
Filter monitoring:
Pre-filter indicator/reset button
The pre-filter clean indicator light will blink after being used about 1 month. Please clean it with vacuum
cleaner or wash by cleaner water and ensure it dry completely.
Please reset the indicator according to 3 Operating Instructions in Page 4- Filter replacement reset.
VOC filter indicator/reset button
If the air purifier has been used for about 3 months, VOC filter indicator will flash to remind you to replace the
filter. After replacing, please reset the indicator according to 3 Operating Instructions in Page 4-Filter
replacement reset.
Tips: Based on different environments of use, it is recommended to replace the filter every 3 ~ 6 months.
Child Lock
AUTO Mode
Sleep Mode
Dimmer
Power
Quick Mode
Speed
Timer
Touch
Lock
Quick
Speed DimmerTimer
Sleep AUTO

Camfil – Clean Air Solutions 7
User Manual
Control panel / Maintenance
Cleaning and maintenance ofthe machine
After the filter cover is removed,
use a vacuum cleaner small brush
head or wet cloth to wipe the filter
cover. Wait for it to dry, and then
fit it back into the machine.
Gently wipe the air purifier body
with a wet cloth. Do not allow
water to flow into the air outlet or
inlet, otherwise, the motor or
switch will be damaged.
Notes
Do not immerse the air purifier in water, use chemical agents
to clean the machine, nor allow water to flow into the machine.
Final filter indicator/reset button
If the air purifier has been used for approximately 12 months, the final filter indicator will flash to
remind you to replace the filter. After replacing, please reset the indicator according to 3
Operating Instructions in Page 4- Filter replacement reset.
Tips: Based on different environments of use, it is recommended to replace the filter every 12 ~ 24
months.
Pre filter + VOC filter + Final filter:
City Touch is equipped with 3 sets of filters, Pre filter – to remove bigger particles like >PM10,
VOC filter - to remove odour and VOCs, and Hepa filter – to remove bacteria, fine particles,
allergens, smoke and haze.
We recommend that you clean the prefilter by vacuum cleaner to remove bigger dust particles.
VOC and Final Filter should be replaced, not cleaned.
Touch

Turn off the air purifier
and unplug it
.
Open the filter covers on the
left and right side:
Pull out the filter cover from
the upper part on both sides
.
Take out the pre filter
and VOC filters (remove
the plastic bags ofnew filters)
.
Lift the final filters
outward and take it out
along the chutes on both
sides
.
Clean the pre filter with a
vacuum cleaner
.
Put the filters back in
order, and replace the
filter covers.
Air quality
sensor
Tips
In order to better use the air purifier,
do not block the openings of the
VOC sensor or particulate sensor,
or the dust sensor on the strip behind
the machine. Keep them clean and
free from obstruction .
4
1
1
2
2
6 Clean and replace the filters
Camfil – Clean Air Solutions 8
User Manual
Rotate the Fixing knob
.
Insert the plug again, press power
button to start up the air purifier. press
( ) key to switch the specified filter,
activating the corresponding indicator
light for constant brightness. Then
press the ( ) key again 3 seconds
to reset the timer.
Touch
FINAL
VOC
PRE

Camfil – Clean Air Solutions 9
User Manual
Normal Problems
Normal Problems Common causes
Check whether the power cord is properly plugged in.
Check whether the plastic bags of the filters are
removed.
Check whether the filters are properly fitted in.
Whether the filter covers are properly covered?
Whether the air outlet on the top of the air purifier is
blocked, if yes, the operation of the machine will be
affected.
Whether a operation time has beenset, and the time
is up now.
Why is no air blown out?
How often shall I replace the
final filters?
Why do I need to clean the prefilter?
Please contact our customer service at your nearest Camfil office for any assistance or to purchase filters.
The filter is the core of the air purifier, regularly
clean the filter canimprove the efficiency of the
cleaner and prolong the lifetime of it. The surface
can be cleaned after the filter has been used
for a period of time. Please clean the filter according
to the instructions.
Based on the use environment of the user, ifthe air
quality is poor, or the cleaner is usedina newly
decorated house, itis recommended that the filter
shall be replacedmore often, to ensure the best
filtering effect. City Touch uses an internal timer. If the
time of each filter reaches the replacement
limit, the replacement indicator will flash to remind
you to replace the filter. Please clean the filter
according to the instructions, put it back into the
cleaner, and insert the plug, press the corresponding
filter button (reset button) for 5 seconds to reset the
timer.
Ensure that the air inletand filtered air outletare not
blocked.
Remove the plastic bags ofall filters.
Check the conditions of the filters, clean them if
necessary.Consider the replacement of the filters
after a period of use.
Ensure a distance of atleast30 to 90cm from the
grill of the air inlet to the wall or things around it.
Touch
Why does the airfow decrease
after a period of use?

Camfil – Clean Air Solutions 10
User Manual
Safety Instruction
Please read the operating manual carefully before use, and keep it for future reference.
This manual is applied to City Touch, please operate according to the instructions for the model you
purchased.
When using electrical appliances, we should have basic safety knowledge in order to avoid fire,
electric shock and other injuries.
Therefore, please observe the following instructions
Pay attention to safety when using
electrical appliances, in order to avoid
the risks of fire, electric shock and
other injuries.
Do not use the air purifier if the electric
wire, plug or the product has been
damaged.
Do not use the air purifier outdoor.
Do not use the air purifier if thefilters
are not complete.
Do not place thewire under the carpet
or close to aheatsource.
Replace thefilters when thefilter
indicator light is on to ensure the
cleaning performance of the air purifier.
If the power cord is damaged, it must
be replaced or repaired by the
manufacturer or after service to avoid
danger.
The air purifier must be erect.
Do not allow objects to enter or block
the air inletand outlet, or the air
purifier will be damaged.
Do not sit, stand or place items on
top of the air purifier.
Do not use the air purifier in places that
are exposed to moisture or water splash,
such as bathroom, kitchen, beside the
sink or basement that is seriousdamp.
Do not use the air purifier around
flammable gas or steam.
Preparation before use
Take out the air purifier from the packing box, positioning it on a even and steady floor. Keep a distance
of atleast 60cm away from the wall or other funiture to ensure air circulation.
Please operate according to the yellow instruction label, open the filter covers on the both sides of the
machine outward, take out the primary filters, rotate the fixed knobs above the filters, take out the
activated carbon filters and anti-allergy filters (remove plastic bags of all filters, and recover them in
accordance with local government requirements to avoid misuse of children), then put the filters back
to their original positions, and cover the filter covers.
Children should not operate this unit unsupervised.
Now you can use the air purifier and enjoy the fresh air.
(Notes: Remove all packaging material prior to use to aviod blockage of the air outletand inlet.)
Touch

CAMFIL is the world’s largest and
leading manufacturer of filters and
clean air solutions.
Camfil is the global industry leader in clean air
solutions with more than 50 years of experience.
Our solutions protect people, processes and the
environment to benefit human health, increase
performance, and reduce and manage energy con-
sumption. 26 manufacturing plants, 6 R&D sites and
65 local sales offices worldwide provide service
and support to our customers. The Camfil Group is
headquartered in Sweden but more than 95% of
sales are international. The Group has approximately
4,000 employees and sales more than SEK 6.7
billion.
Table of contents
Other Camfil Air Cleaner manuals