CMX-3G-4SDI Set Up Instructions
1. Secure the units in a safe locaon, where they will not be subject to impact and where there is
room around the unit so nothing will interfere with the fiber opc cabling causing it to bend sharply
in a ght radius in any way which can severely affect the signal transfer.
2. Carefully connect your source(s) to the transmier input(s) and the receiver unit output(s) to your
receiving device input(s) using the BNC connectors on the transmier and on the receiver unit.
3. CLEAN* the ST fiber opcal cable contacts that will be used for connecng the Tx and Rx units and
aach the fiber cable to the ST connecons and secure, as you would secure a bayonet BNC. While
pressing lightly in on the connector, twist it in a clockwise direcon about 1/8 to 1/4 of a turn and
then release. The connector should stay inserted and have backwards spring pressure holding the
bayonet in place.
4. Connect the included power supplies to the transmier & receiver units, and plug them both into
an AC power source.
* CLEAN: All fiber opcal cable contacts (the end that is inserted and makes contact to enable light
wave transmission through the fiber) require cleaning each me before inserng into a device’s out‐
puts or inputs. Failure to clean the contacts can damage the unit’s opcs over me and also render the
cable and the device nonoperaonal.
Use cleaning kits designed specifically for fiber opcs. Other cleaners may add contaminants not seen
by the naked eye which could damage cables and/or equipment.
Camplex CMX‐3G‐4SDI Page 5