Capstone CS-6000 User manual

CAPSTONE
頂石雲端
FIRE ALARM
Residential
Fire Alarm Sounder
Installation Instruction

Contents
1. Product Information
2. Function Definition
3. Description of Installation Space Configuration Planning
4. How to avoid the improper installation position?
5. Looking for the best installation position
6. Test and Maintenance of the Residential Fire Alarm Sounder
7. Setup environment
8. Quick installation method
9. Installation Situation Description
10. APP Tutorial
10-1. Download Tutorial
10-2. Account Registration
10-3. Device Setting
10-4. Device Sharing Setting
10-5. Edit Device
10-6. Edit Group
10-7. Self-set Temperature Remind Setting
10-8. Notification Setting
10-9. Android System Instruction
10. FCC Statement:
1
2
3
4
4
5
6
6
8
9
9
10
11
14
18
19
20
21
22
23

Name Residential Fire Alarm Sounder with Photoelectric/Constant Temperature
Model CS-6000
Type
Input Power
Voltage 110VAC/220VAC
Current 45mA
Frequency 50 / 60Hz
Standby
Battery
Brand Panasonic eneloop
Specification
BK-3MCCE
1.2 VDC 2000mAh/AA Nickel-Hydrogen
Self Discharging/Charging Battery
Wire
Parameters
Equipment Name CS-6000M
NCC License No.
Wireless Standard 802.11 b/g/n
Frequency Range 2.4GHz~2.5GHz(2400MHz~2483.5MHz)
Security Mechanism WPA / WPA2
Encryption Type WEP / TKIP / AES
CCAN20LP0100T6
Model
Photoelectric Two Types/Constant Temperature
1. Product Information
1

2. Function Definition
1. The residential alarm sounder is mainly powered by supply mains,
and will not start until it is connected with supply mains after installing batteries.
2. Upload a group of document to the cloud about every 60 seconds.
3. When the smoke concentration/temperature reaches the alarm value,
the alarm sound ("beep, beep, beep" continuously) and a red light flashes.
4. When the temperature reaches the alarm value, the early alarm sound
("beep ~” long sound) and a red light will be on.
5. When the smoke concentration/temperature is in normal condition,
the green light flashes every 5 seconds.
6. The device is equipped with standby power source, which can keep the device running
continuously for a period of time after the supply mains is cut off.
(When the battery is in good condition and fully charged, it can run for more than 24 hours).
7. The battery is the consumable, which will reduce its service life due to its usage and
environment, and is not covered by warranty.
8. When the supply mains provide, if the battery voltage is lower than the charging threshold,
the battery will be charged.
2

3. Description of Installation Space Configuration Planning
It is recommended to install one residential fire alarm sounder on every floor and every separate
compartment in the house to achieve the highest protection function.
The stairwell is a passage for smoke circulation, so it is recommended to install one residential
fire alarm sounder.
If the length of walkway or room exceeds 10 meters, it is recommended to install more than one,
and install the residential fire alarm sounder at the both ends.
Penthouse
Bedroom BathroomBedroom
Kitchen Living
Room
Garage
Storeroom
Dining
Room
It's strongly recommended to
install, to provide basic protection.
It's strongly recommended to enhance the
installation, to reach the best security
protection performance.
For frequent smoke position, It's
recommended to install the residential
alarm sounder with temperature detection.
3

4. How to avoid the improper installation position
Improper installation position will delay the alarm time, and may also cause "false alarm", thus
affecting the living quality. The following conditions should be avoided:
1. Please do not install in frequently smoky environments, such as poorly ventilated kitchens,
fireplaces, incense burning halls, carpentry studios, and install constant-temperature alarm
sounders as fire detection in the above areas.
2. Do not install in the environment where a large amount of water mist and steam are easily
generated, such as bathrooms and steam rooms. If the area is the necessary alarm location,
it should be at least 3 meters away from the entrance of the area.
3. It should avoid to install at the outlet of heating and cooling air conditioner where it blows
directly.
Fogging caused by different temperature and humidity may trigger alarm by mistake.
4. This residential fire alarm sounder with photoelectric smoke detector is a high-definition
equipment, for example fluorescent lamp’s electronic noise may cause interference, and the
installation place should be more than 1.5 meters away.
5. Looking for the best installation position
Above 15cm
Within 50cm
Above 1.5m
When the residential
fire alarm sounder is
installed on the wall, it
should be within 15~50cm
below the ceiling or floor.
The residential fire
alarm sounder should be
more than 1.5m away
from the air outlet to avoid
the airflow affecting the
detection function.
3
3
4
4
Above 60cm
Above 60cm
Within 60cm
When the residential
fire alarm sounder is
installed on the beam
column, the lower end
should be within 60cm
from the ceiling or floor.
When the residential
fire alarm sounder is
installed on the ceiling, it
should be more than 60cm
away from the wall or
beam column, and it
should be installed at the
center of the room.
1
1 2
2
4

1. Press the test button and hear the alarm sound and flashing red light to confirm the normal
operation of the alarm sounder, and test it at least once per month.
2. The dirt on the surface of the residential fire alarm sounder can be wiped with a wrung wet cloth,
but you should be careful that water drops cannot fall into the residential fire alarm sounder, and
the battery should be removed before wiping.
3. When dust or cotton wool covers it, it can be removed by vacuum cleaner to keep the residential
fire alarm sounder in the best condition. Please remove the battery in advance when cleaning.
4. When the supply mains are cut off, if the alarm sounder fails to work normally (the green light
flashes every 5 seconds), please confirm the battery status. If the battery is different, please
replace the battery immediately.
Holding test button
Constant alarm sound
Red light flashes
Vacuum cleaner cleaning
Wrung wet cloth
6. Test and Maintenance of the Residential Fire Alarm Sounder
5

7. Setup environment
1. Firstly, remove the base and fix it on the ceiling or wall. Gently press the bottom plate on the
position to be installed, mark the screw location with a pencil, drill the fixed hole with the
alignment mark of electric drill after removing the bottom plate, and drill into the plastic nail in the
accessories. Align the hole position of the bottom plate with the plastic nail, and lock the screws
for fixation.
8. Quick installation method
Stable WiFi environment. Setup for supply
110VAC/220VAC power source
position.
Built-in AA Nickel-Hydrogen
Charging Battery,
please don't remove.
6

2. Fasten the rechargeable battery of the accessories and press it into the battery slot at the back of
the detector body, fix it in the battery slot, and then fix the battery cover plate with screws.
3. The supply mains wires can be installed on the ceiling or wall according to the requirements, and
the wires can be pulled out from the center hole or the side hole of the bottom plate. And rotate
the host machine on the base and finish installation.
7

9. Installation Situation Description
1. Undecorated/Light Steel Joist Ceiling (Cement, Iron plate, etc.)
1-1.
Use the electric drill to make 2 holes at the installation position, insert plastic nylon anchor (plastic
plug), fix the base with screws, and connect the 110VAC (or 220AC) power source to the base.
After the residential fire alarm sounder is loaded with battery, lock it to the base, and then set the
APP.
1-2.
Adhere the base to the installation position with double-faced tape, connect the 110VAC (or
220AC) power source to the base, lock the alarm sounder to the base after charging the battery,
and set the APP after powering on.
1-3.
If there is an idle octagonal junction box, the 110VAC (or 220AC) power source can be connected
to the base through an octagonal junction box, and the base is fixed on the octagonal junction box
with screws. After the residential fire alarm sounder is equipped with the battery, it can be locked
to the base, and the APP can be set after being powered on.
2. Light Steel Joist
Open one small hole above the installation position (the power cord can pass through), then fix
the base with screws or double-faced tape, and connect the 110VAC (or 220AC) power source to
the base from above the light steel joist (the power cord runs inside the light steel joist). After the
residential fire alarm sounder is loaded with batteries, it can be locked to the base, and the APP
can be set after being powered on.
3. Decoration
3-1.
Before decorating, a set of 110VAC (or 220VAC) power source can be reserved at the preset
installation position, and one hole can be opened at this position (the power cord can pass). After
decorating, the base is fixed with screws or double-faced tape, and the 110VAC (or 220VAC)
power source is connected to the base. After the residential fire alarm sounder is equipped with
batteries, it can be locked to the base, and the APP can be set after being powered on.
3-2.
Decorated, fix the base at the installation position with screws or double-faced tape, connect the
110VAC (or 220VAC) power source to the base, lock the alarm sounder to the base after
equipping the battery, and set the APP after powering on.
8

10. APP Tutorial
10-1. Download Tutorial
For mobile phone with Android OS, please search for "HF Alarm" in Google player or scan
QRcode to download and install. For mobile phone with Ios, please search for "HF Alarm" in
Apple Store or scan QRcode to download and install.
9

10-2. Account Registration
10
Please enter Email
Please enter password
Login
Forget password
Login Log-up
Enter Account ID
Enter password
Re-enter password
Log-up
Email
6-12 digits English characters and numbers
6-12 digits English characters and numbers
Log-up
Enter
Verification is successful
I know
Finish
Re-send
1.After installing APP,
please click “Log-up”
button
2.Enter email and
password to start log
up
3.Go to mail box to
receive mail, confirm
and enter 4 digit
verification code
4.Verification is successful
Verification code has been
sent to the following mail
box
Enter
Re-send
Finish
Verification code

Enter password of “capstone_6adc4a”
Cancel Join
New-added device
Password
You can approach iPhone to the connected
network, and your information include iPhone,
iPad or Mac in this network, in order to connect
this Wi-Fi network
New-added device
Please power on the residential
fire alarm sounder
and press “Setting” key
Have completed
Next Step
New-added device
Setting
Network
Other..
Enter password
“firecloud” to connect
Cancel Enter password Join
Password firecloud
Have completed
Next Step
Safety level is
Company Machine
Machine
Other...
wifi-08
Set up
Network
1.When theresidential fire alarm
sounder is powered on and press
“Setting” key, Check APP and
go to NextStep
2.Turn on *Wi-Fi
searching“Capstone”
network and connect 3. Enter password
“firecloud”
4.Connection is
successful
10-3. Device Setting
11

5.Enter the
pre-connected Wi-Fi
name and password of
device to connect
6.Scan the QR-code
at back of device,
finish pairing
7-1.The new device
name group can be
selected according to
the household unit
7-2.The new device
name group can be
selected according to
the household unit
2A:QD:a4:DQ:XA:XA
New-added device New-added device
Enter the pre-connected Wi-Fi
name and of device
This device only supports 2.4GWi-Fi
connection and Wi-Fi name only
supports English characters
And enter password
Please enter WI-FI
Please enter password
Next Step
Scan the QR-code at back of device
Please aim the lens at the box on
the screen
New-added device
New-added device group
Select your space
New-added device
New-added device group
Select your space
Flat
Single
Single Family
Multiple
Single
Family
Flat
Single Story
Confirm Confirm
Please select floor for installation
12

New-added device
Select
Living Room
Main Bedroom
Bathroom
Kitchen
Dining Room
Confirm Confirm
New-added space
New-added device
Select
New-added
Confirm
Cancel
New-added space
New-added device is completed
Setting is
Congratulation
Device has been
successfully set.
Capstone FireCloud Co., Ltd
Concern about your house safety
Confirm
8-1.Select space for
installation
8-2.Add new space by
yourself
9.Complete device
setting
10.The homepage
displays connected
device status
Guest
Normal
My Group
All
13

10-4. Device Sharing Setting
1.Click option at right
upper corner,
Click the left menu
Device Sharing
2.Click “Share Device”,
and select the device to
be shared.
3.Skip to the next screen,
clic
14
Disclaimer
Edit Device/Group
Device Sharing
Notification Setting
Log out
No Signal
No Signal
Shared List of 1F-Living Room-01
Device Sharing
Device Sharing Share Device
1F-Living Room-01 Not Share

5.Enter shared accounts, and
press “send”, share invitation
shall be sent.
4.If you need to share multiple
devices at one time, press and hold
the devices to select multiple
devices, and then press the following
15
I know
Confirm
Device
My Device Share
1F-Living Room-01
3F-Main Bedroom-01
Have Shared
Not Share
Please enter Capstone account of part:
Recently Shared Accounts
Sharing Invitation has been sent

6.For the sharing party that has
not installed the device, click the
device to share
7.Sharing party click “Share
Device”, Re-click shared device,
the receiving notification shall
be popped up, confirm and
complete sharing
Welcome to use Capstone FireCloud
safe home
You still don’t have any device
information
New-added Device
Install
Device Sharing
Obtain space security information
Device Sharing
My Device Share Device
1F-Living Room-01
From
Have Invited
Confirm to accept the
invitation of sharing device?
Cancel Confirm
16

9.Sharing party click “Share
Device”,
Re-click shared device, the receiving
notification shall be popped up,
confirm and complete sharing
8.There has been receiving party of
installed device, click option at
right upper corner, click the left
menu Device Sharing
Device Sharing
My Device Share Device
1F-Living Room-01
From
Cancel Confirm
Have Invited
Confirm to accept the
Disclaimer
Edit Device/Group
Device Sharing
Notification Setting
Log out
No Signal
No Signal
17

10-5. Edit Device
3.Click and Edit
Device Group
4-1.Click device name,
“changing name”
and movable group
shall be popped up.
4-2.Check circle, to
delete device
4.Click “Edit”, select
device to be edited or
deleted
18
Edit
Guest
Normal
My Group
All 168
Disclaimer
Edit Device/Group
Device Sharing
Notification Setting
Log out
Instructio
No Signal
Edit Device
No.168 5F
Guest
1.Click option at
right upper corner
2.Click the left menu
Edit Device/Group
Edit Device
No.168 5F Move delete
Guest
Change Space Name
Name
Floor
Guest Room
ConfirmCancel
Edit Device
No.168 5F Move delete
Guest
Delete Device
You will lose device information
Cancel Confirm
Edit Group
My Group
No.168 5F
Edit
Table of contents
Popular Fire Alarm manuals by other brands

UniPOS
UniPOS FD 7201S instruction manual

Siemens
Siemens DBS721 Installation

Global Fire Equipment
Global Fire Equipment ZEOS-AD-S manual

E2S
E2S BExCP3A-PB instruction manual

Fire-Lite Alarms
Fire-Lite Alarms MS-9200 Programming, installation, maintenance and operating instruction manual

Teletek electronics
Teletek electronics SensoIRIS WSST Installation instruction