CONTENTS
1. THE MODELS......................................................................................................................................................................... 3
1.1 The accessories...................................................................................................................................................................... 3
2. DESCRIPTION OF THE MAIN COMPONENTS AND FUNCTIONS ................................................................................ 4
2.1 Level control.......................................................................................................................................................................... 5
2.1.1 Working level switch......................................................................................................................................................... 5
2.1.2 Safety level switch............................................................................................................................................................. 5
2.2 Overfill device....................................................................................................................................................................... 5
2.3 Regulation of steam production.............................................................................................................................................. 5
2.4 Measurement of the conductivity of the supply water - alarm thresholds................................................................................. 5
2.5 Automatic draining................................................................................................................................................................ 5
2.6 Foam elimination procedure................................................................................................................................................... 5
2.7 Safety thermostat ................................................................................................................................................................... 5
2.8 Autotest procedure................................................................................................................................................................. 6
2.9 Measurement of the water temperature and pre-heating (not available in the version with type C control module)..................6
2.10 Dehumidification request signal (not available in the version with type C control module) ..................................................... 6
2.11 Deposit detector for the heating elements (optional in the version with type C control module, std. in the versions with type H
or T control module) ........................................................................................................................................................................... 6
3. REGULATION PRINCIPLES................................................................................................................................................ 7
3.1 ON/OFF regulation (control module C).................................................................................................................................. 7
3.2 Modulating regulation (control module H).............................................................................................................................. 7
3.2.1 ON/OFF regulation (parameter A0=0)................................................................................................................................ 7
3.2.2 Autonomous regulation with relative humidity transducer (parameter A0=2)...................................................................... 7
3.2.3 Autonomous regulation with ambient relative humidity transducer and supply humidity limiting transducer (param. A0=3)8
3.2.4 Application for steam baths (type T control module) .......................................................................................................... 8
3.3 Setting the alarm thresholds (type H or T control module)...................................................................................................... 8
4. MOUNTING THE UNIT......................................................................................................................................................... 9
4.1 Receipt and storage................................................................................................................................................................ 9
4.2 Dimensions and weights ........................................................................................................................................................ 9
4.3 Removing and replacing the front casing................................................................................................................................ 9
5. POSITIONING THE UNIT................................................................................................................................................... 10
5.1 Fastening............................................................................................................................................................................. 10
6. HYDRAULIC CONNECTIONS............................................................................................................................................ 11
6.1 Supply water characteristics................................................................................................................................................. 11
6.2 Characteristics of the drain water......................................................................................................................................... 11
6.3 Technical specifications....................................................................................................................................................... 11
6.3.1 Table of technical specifications....................................................................................................................................... 12
6.3.2 Diagram of hydraulic connections .................................................................................................................................... 12
6.4 Checks................................................................................................................................................................................. 12
7. ELECTRICAL CONNECTIONS .......................................................................................................................................... 13
7.1 Power supply voltages.......................................................................................................................................................... 13
7.2 Checking the voltage of the auxiliary circuit transformer...................................................................................................... 14
7.3 Main control board............................................................................................................................................................... 14
7.4 Description of the terminal block and connections (functions and electrical specifications)............................................................ 14
7.5 Auxiliary connections........................................................................................................................................................... 15
7.5.1 Type C control module with ON/OFF action.................................................................................................................... 15
7.5.2 Type H control module with modulating action ................................................................................................................ 15
7.5.3 Control module T for steam baths with modulating action................................................................................................ 16
7.6 Other auxiliary contacts ....................................................................................................................................................... 16
7.6.1 Alarm contact .................................................................................................................................................................. 16
7.6.2 Dehumidification contact ................................................................................................................................................. 16
7.6.3 Remote terminal / supervisory system.............................................................................................................................. 16
7.6.4 Using different brand probes............................................................................................................................................ 17
7.7 Checks................................................................................................................................................................................. 17
7.8 Wiring diagrams for the connection of the elements at the headers ....................................................................................... 18
7.9 Single-phase wiring diagram for 2-4kg/h humidifiers with type C control module................................................................. 19
7.10 Single-phase wiring diagram for 2-4kg/h humidifiers with type H or T control module......................................................... 20
7.11 Single-phase wiring diagram for 6kg/h humidifiers with type C control module.................................................................... 21
7.12 Single-phase wiring diagram for 6kg/h humidifiers with type H or T control module ............................................................ 22
7.13 Three-phase wiring diagram for humidifiers with type C control module.............................................................................. 23
7.14 Three-phase wiring diagram for humidifiers with type H or T control module....................................................................... 24
8. Steam distribution.................................................................................................................................................................. 25
8.1 Ambient steam distribution: ventilated steam distributors..................................................................................................... 25
8.2 Steam distribution in cold rooms.......................................................................................................................................... 25
8.3 Ducted steamdistribution:linear and concentrated jet distributors (OEM)................................................................................... 25
8.4 Concentrated jet steam distribution (OEM).......................................................................................................................... 26
8.5 Positioning linear distributors in the air duct........................................................................................................................ 26