To install this mode[ with a 240v tim cot!:
1 Turn air cleaner OFF using ON/OFF rocker switch ]o_ted
on front panel.
2 Plug power cord into acceptable receptacle
3 Replace the unit door to the front of the air cleaner
4 Air cleaner will now operate when door is in place,
ON/OFF rocker switch is in the ON position and input
voltage is present to unit
System Checkout
ELECTRICAL. SHOCK HAZARD
Failure to follow this warning could result in personal injury
or death.
The following procedures could expose hazardous live
components Only a trained, experienced service person
should install this electronic air cleaner. Before performing
installatlon, service or maintenance operations on unit, turn off
all power to unit. TAG DISCONNECT SWITCH WITH
LOCKOUT TAG.
l. "lqre HVAC system blower should be turned OFF
2. Switch the ON/OFF rocker switch to the ON position. The
bright red segment of the rocker ,.switch should be visible
3. Inspect both the Green INPUT POWER light and the Red
CELL ENERGIZED light:
• With the AFS installed, the Red CELL ENERGIZED
light should go out in approximately 20 to 60 seconds.
This is the normal time for the electronic airflow sensor
to complete its stabilization period Both lights will come
back on when the HVAC system blower begins to
operate.. See the section entitled HOW THE AIRFLOW
SENSOR WORKS for more information.
4. Wait approximately one (I) minute and turn the HVAC sys-
tem blower ON Most thermostats have a setting that wilt
allow you to run the fan manually If not, then set the ther-
mostat so that either hot or cold air begins to flow through
the ductworko
5. The Green INPUT POWER light and Red CELL ENER-
GIZED light should come on.
6 Check to make sure that the Red CELL ENERGIZED light
goes out when the following conditions occur:
" Cell access panel is removed
- Rocker switdl is switched to the OF F position
,' HVAC system blower is not running
COMMONLY ASKED QUESTIONS
Qo WKy Isn't my Bl_ cqtDaH` cQEnlag my Blv?
A. The air cleaner is most likely working just like it was designed.
However, many factors can affect the performance of the unit_ Are
cold alr registers located in the ceiling? If so, it will be difficult for
the airflow to carry heavier particulates to the air cleaner If the dirt
chrw'v_r/,_'_lorqtoaru_:t_'_rarp _tt_ _OoAm
both the Red and Green lights illuminated? If not, then the unit
may be in need of servicing. Contact your local HVAC dealer for
asslstance_
Qo It s_n't eqtDalng my I_ tKHZI_ I zUnt It,tit WIrq3teEn I
do?
A. We recommend that you run the blower continuously so that
the air movement will carry the dirt to the air cle,'mer.
Unfortunately, there will _flways be some dirt that is left behind on
the appliances, furniture, etc Regular dusting is recommended to
stir up these pockets of dust so that they can enter the alrstrcam and
be removed by the Electronic Air Cleaner
n,, t hen Iturn on my Eh:ctronic Air Cleanerlthe lights come
on for a couple of seconds and then turn off., The air cleaner
Isn't zRrklng!
AThe air cleaner is fine as long as both the Red and Green lights
are coming on. Try turning the HVAC blower OFF and then
turning the Electronic Air Cleaner on This should solve the
problem.
nt hat is rite zapping noise I am hearing from my unit?
Should I be concerned?
A. The zapping or popping noise that you are hearing is the sound
of larger particles being vaporized by the ionizing-collector cell.
This is normal and is no cause for alarm.. As your HVAC system
blower moves the air through the dnctwork and allows the
Electronic Air Cleaner to clean the air, the noise will diminish
However, there will always be instancea when larger particles enter
the ionizing-collector cell
nShould I hear thL_ zapping noise all the time?
A._ All Electronic Air Cleaners will occasionally zap or pop as
larger particles pass through the ionizing-collector cells. However,
if the sound is constant or is repetitive in nature, then alarge
particle may have become lodged in the ionizing-collector cells
and they may require cleaning If cleaning the ionizing-collector
cells does not stop the noise and there are no large particles trapped
in the ionizing-collector cells, then the cause could be a
bruken!toose ionizing wire, bent collector plate or other mechanica!
reason. Please contact your local HVAC dealer for a._sistance..
n o t hat if Ino longer' hear any popping or zapping noises
coming from my unit? Is it still denning the air"?
A. If the zapping noises stop and the air cleaner is not in need of
servicing, then one of two situations has occurred.. Flint, the
Electronic Air Cleaner has successfully removed all larger particles
from the air and is cleaning microscopic particles which do not
cause the zapping noise Second, the blower and/or HVAC system
is not running and air is not flowing through the ductwork. The
Electronic Air Cleaner cannot remove particles if the air stream is
not moving.
n. I lost power to my home during a storm,, Should I worry
about the Electronic Air Cleaner'?
A. The most common problem associated with power outages is
the unit will not turn on properly after power is restored. If the Red
and Green light come on for a couple of seconds and then go off,
the unit is OK gust turn the HVAC blower off, turn the unit ON
and then turn the blower back on If the Red and/or Green light
does NOT come on after a storm, the power supply in the
Electronic Air Cleaner may be short circuited. Contact a local
HVAC contractor for further information_
n. My installer told me to keep the H s AC system blower
running _KHtlmH l_t IdRn't Z13at tRlncrHyHmy SIGH"
bill, t hatshould I do?
A.. It is recommended that you keep your HVAC sy_em blower
running all the time to achieve the maximum air cleaning
efficiency. This will allow the Electronic Air Cleaner to do what it
is designed to do, which is clean the air. Remember that if the air
does not reach the air cleaner, it cannot be cleaned On average,
your Electronic Air Cleaner will use the same amount of electricity
as a55 watt light bulb. The energy usage of the HVAC system
blower will depend on the age of your system, energy costs in your
regional location and other variables The best solution is to try
running the HVAC system blower in continuous mode for a month
or two to estimate your annual energy costs and base your final
decision on what you fee! most comfortable with.