providedattherearofthe tray allowing the option to permanently
wire the unit directly to a furnace control,
AirFlow Sensor (AFS)
This part controls the operation of the unit by sensing the
movement of air within the duct This helps to reduce power usage.
How to Identify Which Air Cleamer Model You Own
The model number and serial number for your Electronic Air
Cleaner can be found on the data label located on the inside of the
access door
Facts You Should Know About Your New
Electronic Air Cleaner
Dus_g and "Whi_usW
Your new Electronic Air Cleaner will efficiently clean and filter
your household air. Unfortunately, it will not eliminate the need for
regular dusting of your furniture and belongings. Due to the design
of all duct-mounted air cleaners, they can only clean the air that
reaches tbe air cleaner.. Therefore, if the particulates are not being
carried to the air cleaner in the air _tream, the air cleaner cannot
remove them from your home Occasionally a "white dust" may be
noticed in bedrooms or newly furnished rooms. This is mainly
composed of lint which, because it is heavier than other
particulates, settles before it reaches your unit_ This "white dust" is
not mixed with airborne dirt particles, therefore, it is clean and has
no staining or soiling properties.. However, running the furnace
blower continuously, day and night, will help reduce this from
occurring.
Ozone
Under normal operating conditions all Electronic Air Cleaners
produce minute quantities of ozone as an incidental by-product._ In
fact, all electronic products, such as televisions, cordless phones
and refrigerators, produce some amount of ozone. The average
homeowner can detect the smell of ozone concentrations as low as
25 to 100 ppb (parts per billion) The design of this unit hag been
tested and ozone production is approximately half of the published
permias_le limits established by the Environmental Protection
Agency.. These limits recommend that the concentration of indoor
ozone not exceed 50 ppb.. Ozone is not harmful in these
concentrations. In fact, the ozone level in major cities can
sometimes reach as high as 100 ppb on a summer day. The
addition of optional charcoal after-filters can help reduce this
Normally, a new unit will produce more ozone than one that has
been in operation for several weeks.. This is due to sharp comers or
manufacturing burrs on the ionizing-conecting ceil(s) and is
normal. As the Electronic Air Cleaner arcs _md zaps, the voltage is
vaporizing these areas and tends to round them off This is part of
the breaking-in period of ownership and the issue is
self-correcting Also, high-altitude locations can be more
susceptible to noticing the presence of ozone. An
ionizing-collecting cell that has been damaged or bent (the
designed Macing between electrically charged and ground
components has been decreased) may also produce an abnormal
amount of ozone_
Hew the .'MrFlow Sensor (AFS) Works
Electronic AFS (see Fig 3) was designed to provide an efficient
and reliable method of controlling the operation of the air cleaner
when the dealer is unable to wire the unit directly into the furnace
blower. The electronic AFS is now integrated into the power
supply circuitry and utilizes a thermistor that heals up to
approximately 130°F (54_C). The AFS then stabilizes at this
temperature and when the furnace blower tams on and air flows
through the ductwork, the same vacuum effect pulls cooler air over
the hot surface. This air movement cools down the thermistor and
this cooling down effect allows the electronic AFS to understand
that the furnace blower is moving air and the Electronic Air
Cleaner must turn on to provide air cleaning
Fig. 3 - AJrflow Sensor
A05029
If the air cleaner is installed in a location that is dusty and dirty, the
sensor on the AFS can become coated with dirt and lint.. This
coating am insulate the AFS and keep it from operating properly
To clean the thermistor, tam unit off and allow thermistor to cool, 1
then take a cotton swab dipped in rubbing alcohol and carefully
/
insert it into the hole tocaled on the right hand side of the power
S[2dqt_sl-p E_ (whhn ll2_ing thHunit)ThHho_liS 3/I6" (5 p p ) in
diameter and is located on the front of the power tray assembly..
Carefully twirl the cotton swab between your fingers, making sore
the tip is lightly in contact with the coated bead, cleaning this
coating from the thermistor If airflow sensor is bypa_ed on the
circuit board, the Air Cleaner will run at all times when power is
applied (see Fig 4),
JUMPER AS INSTALLED
AT FACTORY AIRFLOW SENSOR
BYPASSED
Fig. 4-gP9 Prongs
AOSOaO
Outdoor Air
t hen outdoor air is added to the return air duct, sufficient heat
should be added to maintain the return air temperature at 55°F
(t3°C) intermittent or 60'_F (16"C) continuous lower air
temperatures can cause premature heat exchanger or ionizer wire
failures.
Sheet Metal Installations
CUT HAZARa
Failure to follow this caution may result in personal injury..
Sheet metal parts may have sharp edges or burrs. Use care and
wear appropriate protective clothing and gloves when
handling these pnrts.
The Electronic Air Cleaner is adaptable to all new or existing
residential forced air fumaca and cooling systums
qPransitions
If the air duct does not fit the air cleaner cabinet opening, gradual
transitions (see Fig. 5) are recommended to reduce air turbulence
through the air cleaner and maximize efficiency Not more than
20 ° ([_ut 4" /102 p p SHJLanning loot /305 p p )o! FFSD_sion
should be used on each side of the transition fitting