GB - 2
General information
• Check that the power supply at the installa-
tion site is 230 V (min. 198 V - max. 264 V).
• The unit installation must comply with all
applicablelocalandnationalregulations.
•
It is recommended to install a circuit breaker or
a10Asafety fuse upstream of thesupplyswitch.
•Theappliancemustalwaysbeearthed.
• If an extension lead is needed (up to
25 m) make sure that the wire section is
not less than 1.5 mm2.
• Donotlocatetheairconditionerunderdripping
water (e.g.: clothes hung up to dry).
• IMPORTANT: Non-compliance with
these safety standards constitutes a fire
hazard in the event of a short-circuit.
• Themanufacturerdoesnotacceptanyliability
if the safety standards are not observed.
• This unit complies with low-voltage
(EEC/73/23) and electro-magnetic com-
patibility (EEC/89/336) directives.
• The unit is designed to operate within
the following temperature limits:
cooling with dehumidification:
indoor temp. min. 21°C; 50% r.h. - max.
35°C; 60% r.h.
dehumidification:min. 18°C; 65% r.h. -
max. 27°C; 80% r.h.
• Inspect equipment for damage due to
improper transportation or handling: In
case of damage file an immediate claim
with the shipping company.
• Do not use damaged equipment. In case
of a malfunction turn the unit off, discon-
nect the plug from the power socket and
contact a qualified service engineer.
• Use the unit only for factory approved
applications.
• This equipment contains coolant.
Maintenanceoftherefrigerantcircuit
must be carried out by qualified
personnel only.
• All of the manufacturing and
packaging materials used for your
new appliance are compatible with
theenvironmentandcanberecycled.
• Dispose of the packaging material in
accordance with local requirements.
• This equipment contains coolant that must
be disposed of in a proper manner. When
disposing of the unit after its operational life,
remove it carefully. The unit must then be
delivered to an appropriate disposal center
ortotheoriginalequipmentdealer,forproper
environmentally friendly disposal.
IMPORTANT: for UK only
The wires in this mains lead are coloured
in accordance with the following code:
Green-and-Yellow: Earth
Blue : Neutral
Brown : Live
As the colours of the wires in the mains
lead of this appliance may not correspond
with the coloured markings identifying the
terminals in your plug, proceed as follows:
• The wire which is coloured green-and-
yellowmustbeconnectedtotheterminal
in the plug which is marked with the
letterEorbytheearthsymbolorcoloured
green or green-and-yellow.
• The wire which is coloured bluemust be
connected to the terminal which is
marked with the letter Nor coloured
black.
• The wire which is coloured brown must
be connected to the terminal which is
marked with the letter Lor coloured red.
When switching off or moving the unit
to another place wait at least 5 minutes
before restarting the air conditioner.
Always disconnect the cable from the
power socket before moving or cleaning
the unit.
Never use the plug to switch the unit on
or off.
Correct use
The unit is equipped with rollers to
facilitate relocation.
It is recommended to move the unit
holding the front panel as illustrated.
IMPORTANT
At first start-up of the unit proceed
as follows:
• take out the water tank at the rear of
the air conditioner
• remove the adhesive tape strip
• replace the tank correctly in its
position
If the above procedure is not followed,
the unit will not operate and indicate a
fault.
5 MIN.
Do not obstruct the sides and rear grille
with curtains or other objects. Leave at
least 200 mm space from possible
obstructions around the intake grilles.
Do not put objects on the unit.