CC-ISOBUS CCI 1200 User manual

ISOBUS Terminal
CCI 1200
Operating instructions


Contents
About these operating instructions i
About the CCI 1200 iii
1.1 CCI.Apps iv
1.2 Structure v
2Safety 1
2.1 Identification of indications in the operating instructions 1
2.2 Intended use 2
2.3 Safety instructions 3
2.4 Installation of electrical devices 4
3Setting up for operation 5
3.1 Check the scope of delivery 5
3.2 Install the terminal 5
3.3 Connect the terminal 6
3.4 Switch on the terminal 6
3.5Change layout 7
3.6 Select language 7
3.7 Select time zone 8
3.8 Enter terminal licence 9
3.9Activate apps 12
3.10 Setting up the user interface 12
4Graphical user interface 15
4.1 Help 15
4.2 Touch gestures 16
4.3 Layout 17
5Settings 25
5.1 User settings 27
5.2 App settings 29
5.3 System settings 34
6Display of camera images 47
6.1 Setting up for operation 47
6.2 Operation 51
7Tractor combination settings 55
7.1 Setting up for operation 56
8UT and AUX 61
9Data management 63
10 Map view 65
11 Troubleshooting 67
11.1 Problems during operation 69

11.2 Messages 70
12 Glossary 75
13 Disposal 79
14 Index 80
A. Technical Information 81
B. Interfaces 82
C. Time zones 87

i
About these operating instructions
These operating instructions are intended for persons that are entrusted
with the use and maintenance of the terminal. They include all neces-
sary information for safe handling of the terminal.
All information provided in the operating instructions relates to the fol-
lowing device configuration:
Identifier
CCI 1200
Software version
CCI.OS v1.0
Hardware version
1.0
These operating instructions guide you chronologically through opera-
tion:
About the CCI 1200
Safety
Setting up for operation
Settings
User interface
Apps
Troubleshooting
To ensure fault-free operation of your CCI 1200, please read through
the operating instructions carefully. Keep the operating instructions for
future reference.
These operating instructions must be read and understood prior to as-
sembly and commissioning of the terminal to prevent problems during
operation. No liability is accepted for damage resulting from failure to
observe these operating instructions!
If you need further information or if problems occur that are not covered
in enough detail in these operating instructions, then please contact
your dealer or contact us directly to obtain the required information.
Target group
Liability
disclaimer
If problems
arise

ii
Each function is explained with step-by-step instructions. On the left
next to the operation instruction you can see the button to be pressed or
one of the following pictograms:
Enter a value via the keyboard
Enter the value via the terminal’s screen keyboard.
Select a value from a selection list
1. Swipe through the selection list until you reach the desired value.
2. Select the value by ticking the checkbox on the right edge.
Change value
Change an existing value.
Confirm action
Confirm the action carried out previously.
Select list entry
Tick the checkbox to select an element in a selection list.
Switch off
Set the switch to "off".
You deactivate a function or setting.
Switch on
Set the switch to "on".
You activate a function or setting.
Pictograms

iii
About the CCI 1200
We commend you on your purchase of this CCI 1200. The CCI 1200 is a
manufacturer-independent operating terminal for controlling ISOBUS
implements.
The touchscreen of the CCI 1200
Is 12.1" in size and has a resolution of
1280x800 pixels,
Is highly luminous and suitable for
day and night operation and
has an anti-glare coating, which pre-
vents reflections even in direct sun-
light.
The user interface
Offers flexible layouts and displays up
to 6 apps simultaneously,
By use of a user interface developed
from practical experience, enables an
intuitive approach even with complex
functions.
The plastic casing reinforced with
glass beads is highly resistant.
The ON/OFF key as well as two USB
2.0 ports are integrated in the outer
surround to enable quick access.
The interfaces of the CCI 1200
Video, GPS, LH5000, WiFi, ISOBUS,
signal socket, USB: the numerous in-
terfaces ensure maximum connectivi-
ty.
The loud buzzer signals alarm states
and provides audible feedback.
All connectors on the back of the ter-
minal are protected against moisture
and dust by rubber caps.

iv
1.1 CCI.Apps
The following CCI.Apps are installed on the CCI 1200:
CCI.UT
ISOBUS implement operation
CCI.Cam
Display of up to 8 cameras
CCI.Config
Tractor combination settings
CCI.Command
Map view
CCI.Control
Data management
CCI.Help
Help system
The following functions must be purchased separately and can only be
used once enabled:
Parallel Tracking
Creation of tracks
Section Control
Automatic switching of sections
Task Control
Import and export of task data

v
1.2 Structure
1. 12.1" Touchscreen
2. Light sensor
3. ON/OFF button
4. 2x USB 2.0
5. ISOBUS, supply voltage, ECU-Power
6. Signal socket, GPS
7. Camera, video multiplexer
8. 2x USB 2.0
9. Ethernet
10. Buzzer
The terminal is operated via the touchscreen. All common touch ges-
tures are supported.
The light sensor measures the ambient light and matches the screen
brightness to the ambient light.
Touchscreen
Light sensor

vi
The terminal switches off automatically,
if you pull out the ignition key or
turn the ignition key to the OFF position.
The terminal switches back on, when the ignition is turned on again.
Note
The terminal can only be switched on with the ignition key if it has previ-
ously been switched off via the ignition.
Preferably switch the terminal on or off using the ignition key.
Alternatively you can switch the terminal on or off using the "ON/OFF"
button.
Press the ON/OFF button for 1 second to switch it on or off.
The LED integrated in the ON/OFF button displays the current status in-
formation. The LED is off during normal terminal operation to prevent
any disturbance to the driver.
The status displays are described in the chapter Troubleshooting.
Identify your device based on the information on the nameplate. The
nameplate is attached on the back of the terminal.
1. Manufacturer
2. Terminal type
3. Serial number
4. Hardware version
5. Manufacturer’s article number
6. Production date (week/year)
Note
Depending on the manufacturer, the nameplate may differ in layout and
content from the image.
ON/OFF
Nameplate

vii
Both USB interfaces on the left casing side are of type A. Standard flash
drives can be connected.
The USB interfaces on the rear side are type M12. These interfaces pro-
tect the terminal against the penetration of dust and water, even when
there is a connected USB device.
The buzzer is sized so that even if there is a very loud background, ter-
minal and implement audio warnings can be clearly heard.
At connector A, you connect the terminal
to the ISOBUS and
to the power supply.
At connector B, you connect the terminal to
the signal socket,
an NMEA 0183 GPS receiver,
the serial GPS output of the tractor or the automatic steering system,
the serial interface of an N-sensor.
At connector C, you connect the terminal to
a camera or a camera multiplexer,
an NMEA 0183 GPS receiver,
the serial GPS output of the tractor or the automatic steering system,
the serial interface of an N-sensor.
USB
Buzzer
Connector


Safety
1
2Safety
These operating instructions contain basic instructions which must be
observed during setting up, configuration and operation. As such, it is
absolutely essential to read these operating instructions prior to configu-
ration and operation.
Not only do the general safety instructions listed in the "Safety" chapter
have to be observed but also the special safety instructions appearing in
other chapters as well.
2.1 Identification of indications in the operating instructions
The safety instructions in these operating instructions are specially iden-
tified:
Warning - General Hazards!
This occupational safety symbol identifies general safety instructions the
non-observance of which poses a danger for life and limb. Strictly observe
the warning instructions and take particular care in these cases.
Caution!
This caution symbol identifies all safety instructions referring to regula-
tions, directives or working procedures which must be observed. Non-
observance can result in damage to or destruction of the terminal as well
as malfunctions.
Note
The note symbol highlights operation tips and other particularly useful
information.

Safety
2
2.2 Intended use
The terminal is intended exclusively for use with approved ISOBUS im-
plements and devices in agriculture. Any other installation or use of the
terminal is not included within the manufacturer's area of responsibility.
The manufacturer accepts no liability for any resulting personal injury or
material damage. Any risks for unintended use are borne solely by the
user.
Observance of the operation and maintenance conditions stipulated by
the manufacturer also form part of intended use.
The accident prevention regulations in force, as well as other generally
recognised safety, industrial, medical and traffic laws must be observed.
Unauthorised modifications to the device exclude the manufacturer's lia-
bility.

Safety
3
2.3 Safety instructions
Warning - General Hazards!
Please take special care to ensure the following safety instructions are
complied with. Non-compliance could result in malfunctions and conse-
quently danger for any bystanders:
Switch the terminal off if the touchscreen does not respond, the dis-
play hangs or the user interface is not properly displayed.
Ensure that the touchscreen is dry before working with the terminal.
Do not operate the terminal whilst wearing gloves.
Ensure the terminal does not exhibit any external damage.
Caution!
Please observe the following safety instructions to prevent damage to the
terminal.
Do not remove any safety mechanisms or safety signs.
Disconnect the power supply to the terminal during maintenance work
or when using a charging device on the battery of the trac-
tor/production implement.
Do not open the terminal casing. Opening the casing can result in re-
duced terminal service life and malfunctions. If the terminal casing is
opened, the warranty will become void.
Disconnect the power supply to the terminal beforehand when welding
on the tractor or an attached implement.
Carefully read and observe all safety information in the operating in-
structions and the safety labels on the terminal. Safety labels must
always be in a proper legible condition. Replace missing or damaged
labels. Ensure that new terminal parts are provided with the current
safety labels. Spare labels can be obtained from your authorised dea-
ler.
Learn how to use the terminal in accordance with regulations.
Keep the terminal and accessories in good condition.
Only use a soft cloth moistened with clean water or a small amount of
glass cleaning agent to clean the terminal.
Do not operate the touchscreen with a sharp-edged or rough object
because otherwise the anti-glare coating will be damaged.
Do not exceed the temperature range of the terminal.
Keep the light sensor clean.
If the terminal is not fitted in the tractor cab, it should be stored in a
dry and clean location. Do not exceed the storage temperature range.

Safety
4
2.4 Installation of electrical devices
Modern farming implements use electronic components and parts the
operation of which can be compromised by electro-magnetic interfer-
ence from other devices. Such effects can endanger people if the follow-
ing safety indications are not observed.
In the event of retrofitting electric and electronic devices, and/or com-
ponents, in an implement with connection to the on-board network, the
user must independently verify whether the installation interferes with
vehicle electronics or other components. This is, in particular, applicable
to the electronic interference of:
EHR
Front hoisting gear
Power take offs
Engine and gears
It must be ensured in particular that the retrofitted electric and electron-
ic components comply with the EMC Directive 89/336/EC in its respec-
tively valid version and that they bear the CE marking.

Setting up for operation
5
3Setting up for operation
Setting the terminal up for operation is a quick and uncomplicated pro-
cess based on the following step-by-step guide.
3.1 Check the scope of delivery
Check the scope of delivery of your terminal before you start setting up
for operation:
1. Terminal
2. Device holder
3. Cable A
3.2 Install the terminal
The device holder is supplied with terminal and is pre-assembled on the
terminal in the factory. Attach the terminal with the device holder to a
20mm diameter tube.
Fit the terminal in landscape or portrait format.
Note
Ensure that the screws are tightened firmly.
Mount the terminal so that it
Is easy to read and operate,
Does not impede access to the tractor controls and
Does not impede the view to the outside.

Setting up for operation
6
3.3 Connect the terminal
Connect the terminal to the ISOBUS and supply it with power via con-
nector A:
Connect cable A to connector A of the terminal and then to the in-cab
socket of the tractor.
3.4 Switch on the terminal
1. Press the ON/OFF button for 1 second.
The safety instructions are displayed.
2. Drag the "Enter" button in the indicated direction.
The arrow changes its shape to a check mark.
The start screen is displayed.

Setting up for operation
7
3.5 Change layout
As supplied all operating screens are output in landscape format. If you
have installed the device in portrait, then first change the layout:
1. Press the "Settings" button on the start screen.
The "Settings" operating screen is displayed.
2. Press the "Layout" button.
The "Layout" operating screen is displayed.
3. In the "Orientation" line, select the "Portrait" checkbox.
The layout is changed.
4. End the Process with "Back”.
3.6 Select language
As supplied, the terminal displays all texts in English. To change the
language setting:
1. Press the "Settings" button on the start screen.
The "Settings" operating screen is displayed.
2. Press the "User" button.
The "User" operating screen is displayed.
3. Press the "Language" button.
The "Language" operating screen is displayed.
4. Select your language.
The checkbox at the right edge of the button is selected.
The language setting is changed.
5. End the Process with "Back”.

Setting up for operation
8
3.7 Select time zone
The time zone forms the basis for the time displayed by the terminal.
Switching between summer and winter time takes place automatically
and cannot be disabled.
Note
Select the time zone with the correct time difference and the appropriate
region.
1. Press the "Settings" button on the start screen.
The "Settings" operating screen is displayed.
2. Press the "System" button.
The "System" operating screen is displayed.
3. Press the "Date and time" button.
The "Date and time" operating screen is displayed.
4. Press the button "Time zone".
The "Time zone" selection list is displayed.
5. Select the Time zone.
The checkbox at the right edge of the button is selected.
The time zone is changed.
6. End the Process with "Back”.
Other manuals for CCI 1200
1
Table of contents
Other CC-ISOBUS Touch Terminal manuals