CCS PD2 Series User manual

Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra

Operation Manual for the PD2 Single Channel Series
Power Supply Units for LED Lighting
PD2-1012/1024/3012/3024/5024
1. Safety Precautions *Besure to read prior to using theproduct.
Thank youforpurchasingthisPowerSupplyfor LEDIllumination.PleasereadthisOperating
Manual beforeusingthe product,andfollowitsinstructionstoensure safeoperation. Wealso
recommend that youkeepthe OperatingManual togetherwith theproductforlater reference.
Pleaseobservetheitemsmarked withthe Warning, Caution,symbolstopreventinjury,
electricshock, andotheraccidents.
Warning
Indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
Caution
Indicates a potentially hazardous situation which, if not avoided, may
result in injury or property damage.
Warning
(1) Always use one of the following power cables for the PD2-3012, PD2-3024,
and PD2-5024.
100 to 120 V range: SVT type, AWG 18, length: 3 m max., dielectric strength:
125V min. (Note: This power cable is required for compliance with UL)
200 to 240 V range: H05W-F type, AWG 18, length: 3 m max., dielectric
strength: 250 V min. (Note: This power cable is required for compliance with
EU)
(2) Plug in or unplug the power cable after turning OFF the supplied power.
Otherwise, fire or electric shock may occur. Plug the power cable directly into
the outlet.
Do not plug the power cable into an extension cord or into a multiple-type outlet
that have another power cables. Otherwise, fire or electric shock may occur.
Always unplug the unit and peripheral devices from the outlet first before
connecting or disconnecting the unit. Damage to the power cord may result in
fire or electric shock.
(3) If the unit is damaged, turn it OFF, unplug the power cord from the outlet, and
contact the company from which you purchased the product. Continued use of
the unit may result in fire or electric shock.
(4) Follow the operating procedures stipulated for the product in this manual. Failure to do so
may result in diminished protection capabilities.
(5) The unit operates at a power supply voltage of 100 to 240 VAC. The supplied power cable,
however, is for use with 100 V. If the unit is to be used at 200 V or above, use a 200-V power
cable for the 30- and 50-W models.
(6) When the rubber foots are removed to mount the unit in a system rack or case, the portion of
the M3 screws penetrating the case must be less than 5 mm long. If this portion is longer,
internal components may become short-circuited.
(7) Do not open the cover of the Power Supply for LED Illumination.
There are high-voltage parts inside. Opening the cover may result in electric
shock.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

(8) Do not touch the AC power plug with wet hands. To do so may result in electric
shock.
(9) Ground the power supply.
Ground the FG terminal of 10-W models with 0.5 to 1.25-mm2wires (AWG20 to
AWG16) wire if there is a possibility that an operator might touch the power
supply unit and a metallic frame with a different electrical potential at the same
time. If the frame is not grounded and has electric potential, it is better to
connect the FG terminal of the product to the FG terminal of the frame. (Use a
3-prong AC power cable with a ground terminal to ground 30- and 50-W
models.)
(10)
If smoke appears, the product becomes abnormally hot, unusual smells or
sounds are generated, or any other abnormality occurs, stop using the product
immediately and turn OFF the power.
Caution
(1) Illuminators become very hot during use. For this reason, do not use them in a closed space.
If it is necessary to use them in a closed space, provide sufficient cooling in the form of fans
or other cooling devices.
(2) Install the product in places with the following conditions:
・ Horizontal, stable places with little vibration
・ Places with good ventilation and little dust
・ Places that are not subject to sudden temperature changes
・ Places stipulated in the specifications, i.e., places located away from
water faucets, water heaters, humidifiers, coolers, heaters, or stoves.
・ Places that do not have water-containing objects nearby
・ Places where the power switch is readily accessible to ensure that the
power can be turned OFF immediately in an emergency.
・ Always use the product in a place where there is a ground connection.
(3) Observe the following items for the Power Supply:
・ Provide a dedicated power source with stable voltage. Wiring the
product from the same power source as a large device, such as a motor
or an inverter, may result in malfunction.
・ Disconnect the power plug when the product is not to be used for an
extended period of time.
・ Do not place the power cable near a heat-generating device, and do not
allow the power cable to be scratched.
・ In the event of a thunderstorm, do not touch the product case and the
power plug.
2. Overview
This power supply is for exclusive use with LED lighting made by CCS.
1. Dimming can be controlled in internal mode from the intensity control knobs on the front panel of
the PD2 or in external mode using a PLC, microcomputer, or other device.
2. The external ON/OFF control is available in PD2.
3. PD2 models can supply the following power specifications.
PD2-1012: 12 VDC, 0.79 A (9.5 W)
PD2-1024: 24 VDC, 0.38 A (9 W)
PD2-3012: 12 VDC, 2.3 A(28 W)
PD2-3024: 24 VDC, 1.16 A (28 W)
PD2-5024: 24 VDC, 1.92 A (46 W)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

3. Operating Procedure
Turning ON lighting
1. Check the power supply switch to make sure it is turned OFF ( position).
2. Connect the LED lighting to the power supply.
3. Plug the AC power cable of the power supply into
an outlet.
4. Connect an external control connector if it is the
case to use external control.
5. Turn ON the power supply switch ( position).
6. Use the intensity control knobs to set lighting
intensity.
Power OFF
Power ON
Intensity control knobs
Front
Note: The illustration shows
the PD2-3012/24. All
other models operate
the same way.
LED lighting
AC power cable
External control connector
Back
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Adjusting lighting intensity
1. Turn the intensity control knobs on the front panel of the PD2 to set
the lighting intensity.
Each font panel knob controls dimming in 16 steps. With 16 fine
steps for every coarse step (16 steps), the result is up to 256 steps
of extremely fine dimming control.
Turning OFF lighting
1. Turn OFF the power supply switch ( position).
External control
External control
1. A Dsub terminal is provided on the rear panel of the PD2 for external control.
The PD2 can be controlled externally using parallel bit control.
2. Pin bit arrangement for external control terminals
Bit B0 B1 B2 B3 B4 B5 B6 B7 B9 B9 B10
Structure
Dimming bit (0 to FF) EXT
WR ON1
A driver IC or an open collector outputs a signal to each terminal and the external control
signals are input to the PD2 at CMOS level.
3. TheEXCB2-B3isanoptionalexternal control cablemanufacturedbyCCS.
4. The PD2 support the following types of external control.
・ External and manual dimming control selection
・ Dimming settings
・ Lighting ON/OFF control
・ Overcurrent protection signal monitoring
External control connector
Front view
Power supply OFF
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

External control
1. Connect the external control cable to the power supply.
(Also connect the lighting and any other devices.)
2. Input the desired control signal from the external
control cable.
①External and manual dimming control selection
Set bit B8 of the Dsub external control connector to Low to
set the PD2 to external control mode. Dimming from the
front panel is disabled in this mode. Set bit B8 to HIGH to
enable dimming from the front panel and disable externally
controlled dimming.
②Dimming settings
Set the 8 bits from B0 to B7 as well as B9 to control
dimming. Specify up to 256 dimming steps using bits B0 to
B7 and send the write signal to write bit B9 to write the
dimming data to the PD2. Keep the write signal Low for at
least 300 μs to write the data, and switch the signal back
to HIGH after the minimum write time has elapsed to stop
writing data.
Note: Dimming settings are enabled only as long as the
power supply remains ON and will be lost when the power
supply is turned OFF.
③Lighting ON/OFF control
After you have selected the dimming level, use the ON/OFF
signal at bit 10 to control when the lighting turns ON and
OFF.
Write sequence
B0 to B7
(8 bits)
Write bit B9
(WR)
① Dimming data (B0 to B7) is output in negative logic (Low: 1)
② The write bit is output. (Data is written on the falling edge.)
Tst
Thd
Tpw
Write dimming data Tst≧100 μs
Tpw ≧300 μs
Thd ≧100 μs
NPN open collector on
OFF
ON
External control
connector
Power
supply
(rear
view)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Manual ON/OFFcontrol
1. In manual mode, the external ON/OFF control is available for the
illuminator.
2. Insert the phone plug into the phone jack to send the
ON/OFF control signal for manual control (internal ON/OFF
control).
Note: Control is limited strictly to turning lighting ON
and OFF.
Note: This option is not available when dimming is externally
controlled.
Phone jack (Ø3.5) signal line
Overcurrent protection
Overcurrent protection output
The overcurrent protection output is a monitoring signal that
becomes active when overcurrent is detected. It is output from bit
B13. Output circuit is an open collector, with negative logic (active
Low).
The PD2 output stops if lighting current consumption (total of all
channels) exceeds 107% of the rated current consumption. Also, the
red error indicator on the front panel of the power supply will light and
output cannot be resumed until the power supply is restarted.
4. Connectors (cable plug connectors are not included)
1. Output connectors: SM connectors (JST)
Pin
number 12 V output 24 V output 12 V with fan 24 V with fan
1 OUT + (12 V) OUT + (24 V) NC OUT + (24 V)
2 OUT - NC OUT + (12 V) NC
3 OUT - OUT - OUT -
4 Fan GND Fan GND
Connector SMP-02V-BC SMP-03V-BC SMP-04V-BC SMP-04V-BC
With fan: Output connector for lighting L1 (FAN)
NPN open collector ON
Power supply
(rear view)
Phonejack
forON/OFF
controlin
manualmode
(internal
ON/OFF)
control)
Phone plug
ON
OFF
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

2. External control connectors: 15-pin D-sub male with M2.6-mm screws
Use a shielded cable of 3 m or less for the control line.
Optional cablesPin
number Cable color Line color Signal
1
Black
-
Dimming B0 (LSB)
2
White
-
Dimming B1
3
Red
-
Dimming B2
4
Green
-
Dimming B3
5
Yellow
-
Dimming B4
6
Brown
-
Dimming B5
7
Blue
-
Dimming B6
8
Purple
-
Dimming B7 (MSB)
9
Gray
-
External control (INT/EXT) B8
10
Pink
-
Dimming data write (WR) B9
11
White Black Lighting control (OFF/ON) B10
12
Red Black -
13
Green Black -
14
Yellow Black Overcurrent protection (OCP) B13
15
Brown Black Signal GND
Chart legend:
Optional cable for external control:
EXCB2-B3(cable length: 3 m, with one side of the cable cut)
3. Phonejack(Ø 3.5)for manualON/OFFcontrol
Lighting can be turned ON and OFF manually when the phone plug is inserted into the phone
jack. The LED lighting will turn ON when the signal is connected to ground and will turn OFF
when the signal is disconnected from ground.
◇Phone plugs
Contact your nearest CCS representative if you need to extend the control signal cable or operate in
an extremely noisy environment. Cables should not be extended more than 3 m. Potentially harmful
noise may be eliminated by installing a 0.01 to 0.1-μF capacitor between the signal and ground to
ensure proper operation of this product. Phone plugs are not included with the power supply kit, but
optional 3-m cables with plugs are available. (Cable model number: NFCB2-3, with a white wire for
the signal (+) and a black wire for ground (-))
Terminal
Signal
1
Inside ON/OFF signal
2
Outside
GND
Signal (+)
Case
GND(-)
Close-upview
Cablecolor
Linecolor
Optionalcable
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

5. PD input circuit (negative logic)
6. Recommended control signal drive circuits: open collector
photo-coupler, photo-MOS relay
When using the PD2 in a noisy environment,
we recommend that you isolate the signal
and ground lines from the control unit with
photo-couplers or photo-
MOS relays. Any
element that supplies around 10 mA can be
used to drive the circuit.
Dimming data: B0 to B7
Control signals: EXT, WR, and ON
Output using a driver IC or NPN open collector
(Maximum allowable input voltage: 12 V)
LS05,
LS06,
etc.
GND
Signal
Photo-MOS
switch
relay, etc.
GND
Signal
IN
4.7 k
1 k
74HC14
+5V
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

7. Appearance(mm)
PD2-1012/1024
ManualON/FF control
Phonejack
Output Connectors
(Insertiondepthless
than2mm)
AC power cable
(2.3 m)
Externalcontrolconnector
Coarseintensity
controlknob
Fineintensity
controlknob
Four,M3holes(depth:3)
54x93(fastening
screwholes)
15 Pin Dsub
Power switch
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Four,M3holes
(bottompanelfastening
screws)40x140
Four,M3holes(sidepanel
fasteningscrews
90x140
(Insertiondepthlessthan5mm)
(Insertiondepthlessthan5mm)
Output connector
SuppliedAC power cable (2 m)
Powerswitch
Externalcontrolconnector
Coarseintensity
controlknob
Fineintensity
controlknob
15 Pin Dsub
PD2-3012/3024
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

8. Important
(1) Suppress heat generation in the LED illuminators that are used.
・The service life of LED illuminators will decrease if they are used at high temperatures.
Dimming the illuminators 50% when used continuously can achieve stable extended
performance.
・ Using the illuminators only when capturing an image (i.e., strobing) will suppress heat
generation and produce the most stable conditions for use.
(2) Do not extend the light output cable to more than 5 m. Otherwise the voltage on either end of
the lighting will decline because of the voltage drop due to the DC resistance of the cable.
Dimming decreases since the voltage supply to the light does not reach the rated voltage
even at 100% dimming.
(3) Bundling the camera cable and the power cable together may adversely affect screen
images.
(4) Color camera with white LEDs
・ The amount of light (brightness) and color may vary with the temperature of the
lighting when using continuously.
・ Adjust the white balance of the camera again about one hour after switching ON the
power.
・ The power supply can be used for strobing as soon as the power is turned ON.
(5) Use cable within the applicable range for external control. A shielded cable shorter than 3 m
should be used for the control line to lessen the chances of picking up noise.
(6) To operate CCS lighting without cooling fans, use ON/OFF control to turn OFF the lighting
when it does not have to be lit in order to lower the temperature of the lighting.
(7) Although the power supply unit has an overcurrent protection circuit to protect the driver
transistor, do not short the power supply output.
9. Specifications
Models PD2-1012, PD2-1024, PD2-3012, PD2-3024, PD2-5024,
Power supply
(See notes 1) (100 to 120 VAC) –15% to +10% (50/60 Hz): PD2-1012, PD2-1024
(100 to 240 VAC) –15% to +10% (50/60 Hz): PD2-3012, PD2-3024,
PD2-5024
Maximum capacity
(See notes 2) 27 VA max. (PD2-1012, PD2-1024)
78 VA max. (PD2-3012, PD2-3024)
122 VA max. (PD2-5024)
Output 12 VDC: PD2-1012, PD2-3012
24 VDC: PD2-1024, PD2-3024, PD2-5024
(Output+/between circuit GND)
Dimming control Dimming method: Approximately 63 Hz pulse duty control
Internal control: Front panel rotary switch (256 step control)
External control: Parallel signal control (15-pin Dsub external control
connector)
Power cable Up to 3 m long AC power cable with a ground terminal (PD2-3012, PD2-3024
and PD2-5024)
Up to 1.8 m long 2- flat prong AC power cable (PD2-1012 and PD2-1024)
Connectors Lighting output: SMP-02V-BC, SMP-03V-BC (female, JST)
Lighting output with fan: SMP-04V-BC (female, JST)
External control: 15-pin D-sub male (millimeter screws)
Manual on/off control: Phone jack Ø3.5)
Start time 0.5 s typ.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Output overcurrent
protection
(See notes 3)
Operates at 107% of the rated current
The Error indicator (red) on the front panel is lit when overcurrent is detected.
This latch-type protection is restored by restarting the power supply.
Insulation/dielectric
strength Between input and output connectors and
between input connector and frame ground:
Between output connector and frame ground:
2,000 VAC for one minute
(10 mA)
500 VDC, 20 MΩmin
500 VDC, 20 MΩmin
Applicable
standards CE marking (EMC: EN61326, LVD: EN61010-1: 2001)
(PD2-3012 and PD2-3024 only)
Operating
environment ・ Temperature: 0 to 40 °C, humidity: 20 to 85% (with no condensation)
・ Altitude: 2,000 m max.
・ Pollution level: 2
・ Protective ground class I
・ Installation category II (restricted to use in indoor environments)
Storage
environment Temperature: -20 to 60°C,humidity: 20 to 85% (with no condensation)
Case SECC t1.0, paint color N3 (leather-tone finish)
Cooling method Natural air cooling
Model Input Output
PD2-1012 100 to 120 VAC (50/60Hz), 27 VA 12 VDC, 9.5 W
PD2-3012 100 to 240 VAC (50/60Hz), 78 VA 12 VDC, 28 W
PD2-1024 100 to 120 VAC (50/60Hz), 27 VA 24 VDC, 9 W
PD2-3024 100 to 240 VAC (50/60Hz), 78 VA 24 VDC, 28 W
Ratings
(See notes 1, 2,
and 3.)
PD2-5024 100 to 240 VAC (50/60Hz), 122 VA 24 VDC, 46 W
PD2-1012, PD2-1024: 86 x 120 x 54 mm (WxDxH)
PD2-3012, PD2-3024: 62 x 170x 110 mm (WxDxH)
Dimensions
PD2-5024: 62 x 230 x 110 mm (WxDxH)
PD2-1012, PD2-1024: 0.6 kg max.
PD2-3012, PD2-3024: 1 kg max.
Weight
PD2-5024: 1.3 kg max.
Accessories 2-m long 3-prong AC power cable with ground terminal
(PD2-3012, PD2-3024, and PD2-5024 only)
Manual, Warranty (external control connector not included)
Notes
1: The operating voltage range is -15% to +10% of the input voltage.
2: Do not exceed the maximum wattage for the total number of circuits.
3: The overcurrent protection circuit is activated when the rated load is exceeded.
(Power supply operation is stopped by internal circuits. Restart the power supply to restore
operation.)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

10. Care and Handling
Warning
・Turn OFF the Power Supply and unplug it from the outlet before handling.
Caution
・ Do not scratch the unit by handling it with a hard object.
・ Do not let water or cleanser enter the unit.
・ Do not use cleansers or chemical agents other than those listed below.
For cleaning, dampen a soft cloth with diluted neutral cleanser, wring out the cloth, and
gently wipe off the unit. Use another soft cloth to wipe the unit dry. To clean the case and
protective sheet, dampen a soft cloth with a diluted neutral cleanser, wring out the cloth,
and gently wipe off the unit. Use another soft cloth to wipe the unit dry.
Warranty
1Duration of warranty
The duration of the product warranty shall be one year from the day of product delivery.
2Extent of warranty
(1) If a fault or defect attributable to CCS becomes apparent during the duration of the warranty,
CCS will in good faith ship a replacement, or replace or repair the defective part of the product
free of charge. The following cases, however, are not covered by the warranty.
・ Faults or damage that occur due to conditions, environments, handling, or usage other than
those described in the Operating Manual and specifications.
・ Faults or damage that occur due to modification of structure, performance, specifications,
etc., by a party other than CCS.
・ Faults or damage that occur due to use of the product other than for its designed purpose.
・ Faults or damage that occur due to reasons scientifically and technically unforeseen at the
time the warranty with CCS was entered into or at the time of shipment.
・ Faults or damage that occur due to natural or human causes not attributable to CCS, such
as saltwater air damage, gas damage, earthquakes, floods, fire, lightning, or armed
conflicts.
(2) This warranty is limited to this product purchased from CCS. Any consequential or other
damage induced by a fault or defect in the product is not covered by the warranty.
(3) CCS shall not be responsible for any damages suffered by the customer because of late
delivery of the product due to a natural disaster or other causes not attributable to CCS.
(4) If CCS does bear responsibility for damage, compensation shall not exceed the cost of
replacing the product.
(5) CCS shall bear no responsibility in any way for damages that occur due to handling as part of
export controls.
(6) This CCS product is designed and produced for use in the conditions and for the purposes
described in the Operating Manual and specifications. Therefore, the warranty does not apply
to nuclear energy control systems, aerospace systems, vehicles, railroad systems, medical
equipment, or other applications that present a significant risk to life or property.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Head Office
Shimodachiuri-agaru, Karasuma-dori
Kamigyo-ku, Kyoto 602-8011 Japan
Phone: +81-75-415-8284, Fax: +81-75-415-8278
http://www.ccs-grp.com
intlsales@ccs-
inc.co.jp
B0839-0020-A
No. MP-097E
Apr.2006
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra
Other manuals for PD2 Series
4
This manual suits for next models
5
Table of contents
Other CCS Power Supply manuals