GENERAL DESCRIPTION
With eFAST MORTICE, the panic exit device and lock latchbolt can be withdrawn remotely.
After the lock has been opened, eFAST keeps the latchbolt and the panic exit device withdrawn for 3 seconds (factory default setting). When
this time has elapsed, the panic exit device automatically shuts.
The automatic locking time can be set for up to 180 seconds by connecting to a PC using the programming cable (accessory item
1.07030.41.0).
If the CISA motor is tted with a timer, the hold open function can be activated at pre-dened times of the day.
INSTALLATION
INTRODUCTION
This manual is an integral part of the product and has been compiled by the manufacturer to provide everyone authorised to interact with it
with the information they may need.
SAFETY REGULATIONS
Read the instructions in the installation and user manual carefully.
All installation and maintenance operations which require precise technical expertise or particular skills must be carried out exclusively by
qualied personnel with the relevant qualications and experience in the sector.
The CISA MOTOR is powered by a power supply with 12V ,l=2A output.
For more information, please refer to the section "Power supply characteristics".
Disconnect the system from the mains during installation.
Do NOT perform electric welding on the lock or any parts of the lock when installed on the door.
Situations arising from momentary power failures are given in the instruction
sheet for the panic exit devices 1.59751.00.0 / 1.59751.01.0.
MOTOR CHARACTERISTICS
See the eFAST MORTICE panic exit device manual
Do not connect the product directly to the mains 230V ~.
CISA declines all responsibility for the compliance of the existing system to current regulations.
CABLE CHARACTERISTICS
See the eFAST MORTICE panic exit device manual
Use the cable supplied with the lock only.
CISA declines all responsibility for the compliance of the existing system to current regulations.
POWER SUPPLY CHARACTERISTICS
The power supply is not supplied with the kit. See item 1.07060.10.0 in the accessories section.
Do not connect the product directly to the mains 230V ~.
A power supply with the following characteristics is recommended:
• Output: 12V, 2A
• Protection with fuse 2A - 250V
• Protection: OVP (overvoltage), OCP (overcurrent)
• Certications: CE, in compliance with directives 2014/30/EU, 2014/35/EU Class 2 (double insulation), LPS source (in compliance with
IEC 60950), SELV, UL Listed or UL Recognized

- 3 -
OPERATION
INTERFACING FOR OPENING
See the eFAST MORTICE panic exit device manual
Diagram 1: example of button/switch connection to lock power supply.
Diagram 2: example of lock connection to intercom
The electric current produced by some intercoms can be high, keeping the panic exit device open even after the opening
button has been released.
It is advisable to interface the intercom with a repeater relay and connect the motor as shown in diagram 3 if necessary.
Diagram 3: example of lock connection to an intercom using a repeater relay
INTERFACING FOR PANIC EXIT DEVICE STATUS
See the eFAST MORTICE panic exit device manual
Connect devices with a maximum current absorption of 0.5A and a maximum voltage of 60V. CISA declines all responsibility
for the compliance of third-party devices used
It is possible to connect the 12V lights (see the accessories) directly to the lock power supply. Respect the polarity (+/-) of the lights/LEDs.
A repeater relay (item 1.07022.20.0) is needed to control locks, electric strike coils or 230V devices.
DIAGNOSTICS
When installation is complete, check operation and any sound signals.
Sound signal are emitted to indicate errors and malfunctions.
Status Action Sound/visual signals (*)
On System correctly started up 2 short sound signals - Flashing green LED inside the motor
Mechanical actions Engaging/withdrawing deadbolts No sound signal
Motor actions
Complete opening
(latchbolt + deadbolts)
2 short sound signals
Motor actions Reverting to starting position No sound signal
Motor actions Motor movement Flashing yellow LED inside the motor
Motor actions Setting hold open mode Yellow LED on inside the motor
Error Rod sensor blocked 1 long sound signal - Red LED on inside the motor
Error Motor in safety timeout 2 long sound signals - Red LED on inside the motor
Error Motor blocked mechanically 3 long sound signals - Red LED on inside the motor
Error Incorrect power supply voltage
Vin <11V
or Vin >16V
4 long sound signals - Red LED on inside the motor
(*) = Sound signals can be disabled through the PC.

- 4 -
FAQ
FAQ
Action Sound signals
Flashing signals
(LEDs inside the
motor)
Possible solution
#1
On
When I turn the motor on, it emits a sound signal
that lasts 3 seconds.
Possible cause:
Damaged rmware
1 error signal
(3 sec ON) Red LED on Call technical assistance to upgrade FW or replace the
motor
#2
On
When I turn the motor on, it emits 3 long sound
signals
Possible cause:
Has not reverted to the correct starting position
3 long sound signals
(0.5s ON- 0.5s OFF) Red LED on Call technical assistance or replace the motor
#3
Error rod sensors
During motor movement, it emits one long sound
signal
Possible cause:
Latchbolt/deadbolts not withdrawn properly
1 error signal
(0.5s ON- 0.5s OFF) Red LED on Check rod is sliding properly.
Loosen motor screws.
#4
Motor timeout error
After 5 seconds from opening signal, it emits two
long sound signals
Possible cause:
The motor is not in the correct position
2 error signals
(0.5s ON- 0.5s OFF) Red LED on Call technical assistance or replace the motor
#5
Lock remains open in hold open mode
The lock does not close after giving the opening
command
Possible cause:
Opening impulse still active
-Yellow LED on
The lock remains open because it is still receiving
an opening command. Connect the wires as shown in
diagram 1.
Check the system.
#6
Sound signals not audible
Possible cause:
Volume set to OFF
Check settings on PC
PROGRAMMING
A programming cable (accessory 1.07030.41.0) can be used to set the opening time and the volume of the sound signals, control the number
of openings and upgrade the lock software.
OnlyauthorisedCISAtechnicalstaandlocksmithsshouldprogrammethemotorandusetheprogrammingsoftware.
Procedure:
1 Request access to the “CisaMotorApp” programme on the CISA website
(https://www.cisa.com/CISAmotor);
2 Connect the cables as shown in the diagram below;
3 Power up the lock;
4 Start up the “CisaMotorApp” programme on a PC;
5 Open the COM port;
6 Select the opening time or the desired volume and click on “Save”
N.B.: Visit the CISA website for more details.
https://www.cisa.com/CISAmotor
Programming cable
Item 1.07030.41.0
(optional)
TXD+
TXD
-
GND
+
-
Red | V+ | Power supply (+)
Black | V- | Power supply (-)
Green | TX- | Programming cable
Green/White | TX+ | Programming cable
12V
I = 2A

- 5 -
© 2022 Allegion
About Allegion
Allegion (NYSE: ALLE) is a global pioneer in seamless access, with leading brands like CISA®, Interflex®, LCN®, Schlage®, SimonsVoss® and
Von Duprin®. Focusing on security around the door and adjacent areas, Allegion secures people and assets with a range of solutions for
homes, businesses, schools and institutions. Allegion had $2.7 billion in revenue in 2020, and its security products are sold around the world.
For more, visit allegion.com.
CISA S.p.A. reserves the right to make any change to the products illustrated in this catalogue without prior notice.
CISA SpA
Via Oberdan 42
48018 Faenza (RA) Italy
Ph. +39 0546 677111
Fax +39 0546 677150
Customer Service and Technical Support
+39 0546 188 0070
cisa.com
cisa.vendite@allegion.com
ACCESSORIES
872
30
20
15,2
55
Concealed cable guard 106515 00 0
23 17
260
Internal cable guard with spring 106515 15 0
35
11
22
13
L
External cable guard with spring (L=300 mm). 106515 20 0
External cable guard with spring (L=600 mm). 106515 21 0
Red LED 107126 01 0
Green LED 107126 02 0
Cabled keypad for individual access control by PIN code, for E0000 CISA MOTOR series
Polished black nish
AVAILABLE FINISHES
- Satin-nished chrome (n. B1)
106525 77 0
Power supply cable (L = 4 m). 107030 40 0
Programming cable 107030 41 0
Power supply:
- Input: 110÷240V
~
50/60Hz 0.7A
- Output: 12V 2.5A Class 2 output
- Certied UL Listed
107060 10 0
11,5
7
5,8
77.6
75