Cisco DWDM-XFP Series Quick start guide

Americas Headquarters:
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
Cisco 10-Gigabit XFP Transceiver Modules
Installation Note
Revised: February 3, 2012
Product Numbers:
This installation note provides the installation instructions for the 10-Gigabit XFP transceiver modules,
which are hot-swappable input/output (I/O) devices that plug into a 10-Gigabit port. The XFP transceiver
modules connect the system module port with a fiber-optic network.
This document contains these sections:
•Overview, page 2
•Safety, page 11
•Required Tools, page 17
•Installing the 10-Gigabit XFP Transceiver Module, page 17
•Removing the 10-Gigabit XFP Transceiver Module, page 19
•Translated Safety Warnings, page 21
•Related Documentation, page 26
•Obtaining Documentation and Submitting a Service Request, page 27
XFP-10G-MM-SR= XFP-10GLR-OC192SR= XFP10GLR-192SR-L=
XFP-10GER-OC192IR= XFP-10GER-192IR+= XFP10GER-192IR-L=
XFP-10GZR-OC192LR= DWDM-XFP-xx.xx= DWDM-XFP-C=
XFP10GLR192SR-RGD= XFP10GER192IR-RGD= XFP10GZR192LR-RGD=

2
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Overview
Overview
The 10-Gigabit XFP transceiver module is a hot-swappable I/O device that plugs into 10-Gigabit ports.
(See Figure 1.) The XFP transceiver module connects the electrical circuitry of the system with the
optical network.
Figure 1 10-Gigabit XFP Transceiver Module
The different XFP transceiver module types are listed in Table 1 and Table 2.
1Transmit optical bore 4Bail clasp (locked position)
2Receive optical bore 5Dust plug
3Transceiver socket connector 6Bail clasp (unlocked position)
3
4
144375
1
2
5
6

3
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Overview
Table 1 10-Gigabit XFP Transceiver Modules
XFP Transceiver Module
Product Number
Description
XFP-10G-MM-SR= Cisco 10GBASE-SR XFP transceiver module for MMF, 850-nm
wavelength, dual LC connector
XFP-10GLR-OC192SR=
XFP10GLR-192SR-L=
Cisco multirate XFP transceiver module for 10GBASE-LR Ethernet and
OC-192/STM-64 short-reach (SR-1) Packet-over-SONET/SDH (POS)
applications, SMF, dual LC connector
XFP10GLR192SR-RGD= Cisco multirate XFP transceiver module for 10GBASE-LR Ethernet and
OC-192/STM-64 short-reach (SR-1) Packet-over-SONET/SDH (POS)
applications, SMF, dual LC connector, industrial temperature range
XFP-10GER-OC192IR=
XFP-10GER-192IR+=
XFP10GER-192IR-L=
Cisco multirate XFP transceiver module for 10GBASE-ER Ethernet and
OC-192/STM-64 intermediate-reach (IR-2) Packet-over-SONET/SDH
(POS) applications, SMF, dual LC connector
XFP10GER192IR-RGD= Cisco multirate XFP transceiver module for 10GBASE-ER Ethernet and
OC-192/STM-64 intermediate-reach (IR-2) Packet-over-SONET/SDH
(POS) applications, SMF, dual LC connector, industrial temperature
range
XFP-10GZR-OC192LR= Cisco multirate XFP transceiver module for 10GBASE-LR Ethernet and
OC-192/STM-64 long-reach Packet-over-SONET/SDH (POS)
applications, SMF, dual LC connector
XFP10GZR192LR-RGD= Cisco multirate XFP transceiver module for 10GBASE-LR Ethernet and
OC-192/STM-64 long-reach Packet-over-SONET/SDH (POS)
applications, SMF, dual LC connector, industrial temperature range
Table 2 10-Gigabit Dense-Wavelength Division-Multiplexing (DWDM) XFP Transceiver
Modules
Transceiver Module
Product Number
Description ITU
Channel
DWDM-XFP-60.61= 10GBASE-DWDM 1560.61 nm XFP (100-GHz ITU grid) 21
DWDM-XFP-59.79= 10GBASE-DWDM 1559.79 nm XFP (100-GHz ITU grid) 22
DWDM-XFP-58.98= 10GBASE-DWDM 1558.98 nm XFP (100-GHz ITU grid) 23
DWDM-XFP-58.17= 10GBASE-DWDM 1558.17 nm XFP (100-GHz ITU grid) 24
DWDM-XFP-56.55= 10GBASE-DWDM 1556.55 nm XFP (100-GHz ITU grid) 26
DWDM-XFP-55.75= 10GBASE-DWDM 1555.75 nm XFP (100-GHz ITU grid) 27
DWDM-XFP-54.94= 10GBASE-DWDM 1554.94 nm XFP (100-GHz ITU grid) 28
DWDM-XFP-54.13= 10GBASE-DWDM 1554.13 nm XFP (100-GHz ITU grid) 29
DWDM-XFP-52.52= 10GBASE-DWDM 1552.52 nm XFP (100-GHz ITU grid) 31
DWDM-XFP-51.72= 10GBASE-DWDM 1551.72 nm XFP (100-GHz ITU grid) 32
DWDM-XFP-50.92= 10GBASE-DWDM 1550.92 nm XFP (100-GHz ITU grid) 33
DWDM-XFP-50.12= 10GBASE-DWDM 1550.12 nm XFP (100-GHz ITU grid) 34
DWDM-XFP-48.51= 10GBASE-DWDM 1548.51 nm XFP (100-GHz ITU grid) 36

4
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Overview
Note The dual LC connector on the XFP transceivers support network interface cables with either Physical
Contact (PC) or Ultra-Physical Contact (UPC) polished face types. The dual LC connectors on the XFP
transceivers do not support network interface cables with an Angle Polished Connector (APC) polished
face type.
Table 3 lists the 80 DWDM ITU 50-GHz channels available to the tuneable XFP transceiver modules.
DWDM-XFP-47.72= 10GBASE-DWDM 1547.72 nm XFP (100-GHz ITU grid) 37
DWDM-XFP-46.92= 10GBASE-DWDM 1546.92 nm XFP (100-GHz ITU grid) 38
DWDM-XFP-46.12= 10GBASE-DWDM 1546.12 nm XFP (100-GHz ITU grid) 39
DWDM-XFP-44.53= 10GBASE-DWDM 1544.53 nm XFP (100-GHz ITU grid) 41
DWDM-XFP-43.73= 10GBASE-DWDM 1543.73 nm XFP (100-GHz ITU grid) 42
DWDM-XFP-42.94= 10GBASE-DWDM 1542.94 nm XFP (100-GHz ITU grid) 43
DWDM-XFP-42.14= 10GBASE-DWDM 1542.14 nm XFP (100-GHz ITU grid) 44
DWDM-XFP-40.56= 10GBASE-DWDM 1540.56 nm XFP (100-GHz ITU grid) 46
DWDM-XFP-39.77= 10GBASE-DWDM 1539.77 nm XFP (100-GHz ITU grid) 47
DWDM-XFP-38.98= 10GBASE-DWDM 1538.98 nm XFP (100-GHz ITU grid) 48
DWDM-XFP-38.19= 10GBASE-DWDM 1538.19 nm XFP (100-GHz ITU grid) 49
DWDM-XFP-36.61= 10GBASE-DWDM 1536.61 nm XFP (100-GHz ITU grid) 51
DWDM-XFP-35.82= 10GBASE-DWDM 1535.82 nm XFP (100-GHz ITU grid) 52
DWDM-XFP-35.04= 10GBASE-DWDM 1535.04 nm XFP (100-GHz ITU grid) 53
DWDM-XFP-34.25= 10GBASE-DWDM 1534.25 nm XFP (100-GHz ITU grid) 54
DWDM-XFP-32.68= 10GBASE-DWDM 1532.68 nm XFP (100-GHz ITU grid) 56
DWDM-XFP-31.90= 10GBASE-DWDM 1531.90 nm XFP (100-GHz ITU grid) 57
DWDM-XFP-31.12= 10GBASE-DWDM 1531.12 nm XFP (100-GHz ITU grid) 58
DWDM-XFP-30.33= 10GBASE-DWDM 1530.33 nm XFP (100-GHz ITU grid) 59
DWDM-XFP-C= 10GBASE-DWDM tuneable XFP (50-GHz ITU grid) See
Table 3
Table 2 10-Gigabit Dense-Wavelength Division-Multiplexing (DWDM) XFP Transceiver
Modules (continued)
Transceiver Module
Product Number
Description ITU
Channel
Table 3 ITU 50-GHz Center Wavelengths and Channel Numbering
Channel ID Frequency
(THz)
Wavelength
(nm)
Channel ID Frequency
(THz)
Wavelength
(nm)
80 195.9 1530.33 79 195.85 1530.72
78 195.8 1531.12 77 195.75 1531.51
76 195.7 1531.90 75 195.65 1532.29
74 195.6 1532.68 73 195.55 1533.07

5
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Overview
72 195.5 1533.47 71 195.45 1533.86
70 195.4 1534.25 69 195.35 1534.64
68 195.3 1535.04 67 195.25 1535.43
66 195.2 1535.82 65 195.15 1536.22
64 195.1 1536.61 63 195.05 1537.00
62 195.0 1537.40 61 194.95 1537.79
60 194.9 1538.19 59 194.85 1538.58
58 194.8 1538.98 57 194.75 1539.37
56 194.7 1539.77 55 194.65 1540.16
54 194.6 1540.56 53 194.55 1540.95
52 194.5 1541.35 51 194.45 1541.75
50 194.4 1542.14 49 194.35 1542.54
48 194.3 1542.94 47 194.25 1543.33
46 194.2 1543.73 45 194.15 1544.13
44 194.1 1544.53 43 194.05 1544.92
42 194.0 1545.32 41 193.95 154572
40 193.9 1546.12 39 193.85 1546.52
38 193.8 1546.92 37 193.75 1547.32
36 193.7 1547.72 35 193.65 1548.11
34 193.6 1548.51 33 193.55 1548.91
32 193.5 1549.32 31 193.45 1549.72
30 193.4 1550.12 29 193.35 1550.52
28 193.3 1550.92 27 193.25 1551.32
26 193.2 1551.72 25 193.15 1552.12
24 193.1 1552.52 23 193.05 1552.93
22 193.0 1553.33 21 192.95 1553.73
20 192.9 1554.13 19 192.85 1554.54
18 192.8 1554.94 17 192.75 1555.34
16 192.7 1555.75 15 192.65 1556.15
14 192.6 1556.55 13 192.55 1556.96
12 192.5 1557.36 11 192.45 1557.77
10 192.4 1558.17 9 192.35 1558.58
8 192.3 1558.98 7 192.25 1559.39
6 192.2 1559.79 5 192.15 1560.20
Table 3 ITU 50-GHz Center Wavelengths and Channel Numbering (continued)
Channel ID Frequency
(THz)
Wavelength
(nm)
Channel ID Frequency
(THz)
Wavelength
(nm)

6
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Overview
Table 4 lists the port cabling specifications for the 10-Gigabit XFP transceiver modules.
4 192.1 1560.61 3 192.05 1561.01
2 192.0 1561.42 1 191.95 1561.83
Table 3 ITU 50-GHz Center Wavelengths and Channel Numbering (continued)
Channel ID Frequency
(THz)
Wavelength
(nm)
Channel ID Frequency
(THz)
Wavelength
(nm)
Table 4 XFP Transceiver Port Cabling Specifications
XFP Product Number Nominal
Wavelength
(nm)
Cable Type Core Size
(microns)
Modal
Bandwidth
(MHz/km)
Maximum Cabling Distance
XFP-10G-MM-SR= 850 MMF 62.5
62.5
50.0
50.0
50.0
160
200
400
500
2000
26 m (85.3 ft)
33 m (108.3 ft)
66 m (216.5 ft)
82 m (269 ft)
300 m (984.3 ft)
XFP-10GLR-OC192SR=
XFP10GLR-192SR-L=
XFP10GLR192SR-RGD=
1310 SMF G.652 — 10 km (6.2 miles)
10-Gigabit Ethernet
2 km (1.24 miles)
OC-192/STM-64 SR1
XFP-10GER-OC192IR=
XFP-10GER-192IR+=
XFP10GER-192IR-L=
XFP10GER192IR-RGD=
1550 SMF G.652 — 40 km (24.86 miles)
XFP-10GZR-OC192LR=
XFP10GZR192LR-RGD=
1550 SMF G.652 — 80 km (49.70 miles)
DWDM-XFP-xx.xx= See Table 2
on page 3
SMF G.652 — 80 km (49.70 miles)
DWDM-XFP-C= See Table 3
on page 4
SMF G.652 — 80 km (49.70 miles)

7
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Overview
Table 5 lists the XFP transceiver modules optical transmit and receive specifications.
Table 5 XFP Transceiver Optical Transmit and Receive Specifications
XFP Product Number Transceiver Operating Mode Transmit Power
(dBm)
Receive Power
(dBm)
Transmit and
Receive
Wavelength (nm)
XFP-10G-MM-SR= 10GBASE-SR, 850-nm MMF
(10.3125-Gbps line rate)
–1.0 (Max)
–7.3 (Min)
–1.2 (Max)
–9.9 (Min)
840 to 860
(TX and RX)
XFP-10GLR-OC192SR=
XFP10GLR-192SR-L=
XFP10GLR192SR-RGD=
10GBASE-LR, 1310-nm SMF
(10.3125-Gbps line rate)
+0.5 (Max)
–8.2 (Min)
+0.5 (Max)
–14.4 (Min)
1260 to 1355 (TX)
1260 to 1565 (RX)
OC-192/STM-64 SR1, 1310-nm
SMF
(9.95328-Gbps line rate)
–1.0 (Max)
–6.0 (Min)
–1.0 (Max)
–11.0 (Min)
1290 to 1330 (TX)
1260 to 1565 (RX)
XFP-10GER-OC192IR=
XFP-10GER-192IR+=
XFP10GER-192IR-L=
XFP10GER192IR-RGD=
10GBASE-ER, 1550-nm SMF
(10.3125-Gbps line rate)
+4.0 (Max)
–4.7 (Min)
–1.0 (Max)
–15.8 (Min)
1530 to 1565 (TX)
1260 to 1565 (RX)
OC-192/STM-64 IR2, 1550-nm
SMF
(9.95328-Gbps line rate)
+2.0 (Max)
–1.0 (Min)
+2.0 (Max)
–14.0 (Min
1530 to 1565 (TX)
1260 to 1565 (RX)
XFP-10GZR-OC192LR=
XFP10GZR192LR-RGD=
10GBASE-ZR, 1550-nm SMF
(10.3125-Gbps line rate)
OC-192/STM-64 LR2, 1550-nm
SMF
(9.95328-Gbps line rate)
+4.0 (Max)
0 (Min)
–7.0 (Max)
–24 (Min)
1530 to 1565 (TX)
1260 to 1565 (RX)

8
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Overview
Table 6 lists the optical specifications of the DWDM XFP transceiver modules.
Table 6 DWDM XFP Optical Transmit and Receive Specifications
Parameter Symbol Minimum Typical Maximum Units Notes and Conditions
Transmitter
Spectral Width — — — 0.2 nm Full width, –20 dB from maximum, with
resolution bandwidth (RBW) = 0.01 nm
Transmitter
center
wavelength
—x
1– 100
1. x is the center wavelength. The center wavelength can vary ±100 picometers (pm).
xx
1+ 100 pm See Table 2 for center wavelengths
Side-mode
suppression ratio
SMSR 30 — — dB —
Transmitter
extinction ratio
OMI 9 — — dB —
Transmitter
optical output
power
Pout –1.0 — 3.0 dBm Average power coupled into single-mode
fiber
Receiver
Receiver optical
input wavelength
— 1530— 1565nm —
Receiver damage
threshold
—— —4.0 dBm—
Dispersion
tolerance
— –500— 1600ps/nm—
Power-Limited Performance (measured at optical signal-to-noise ratio [OSNR] of 30 dB at 0.1-nm RBW)
Optical input
power
Pin –23.0 — –7.0 dBm Measured at a bit error rate (BER) = 1E–12
with an IEEE 802.3 test pattern
Dispersion power
penalty
— — — 3 dB Measured at a bit error rate (BER) = 1E–12
with an IEEE 802.3 test pattern
Noise-Limited Performance (measured at OSNR of 24 dB at 0.1-nm RBW)
Optical input
power
Pin –18.0 — –7.0 dB Measured at a bit error rate (BER) = 1E–12
with an IEEE 802.3 test pattern
Dispersion
OSNR penalty
— — — 3 dB Measured at a bit error rate (BER) = 1E–12
with an IEEE 802.3 test pattern

9
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Overview
Table 7 and Table 8 list the optical specifications of the tuneable DWDM XFP transceiver modules
(DWDM-XFP-C=).
Table 7 Tuneable DWDM XFP Optical Transmit and Receive Specifications
Parameter Symbol Minimum Typical Maximum Units Notes and Conditions
Transmitter
Spectral Width — — — 0.2 nm Full width, –20 dB from maximum, with
resolution bandwidth (RBW) = 0.01 nm.
Transmitter
center
wavelength
—x
1– 25
1. x is the center wavelength. The center wavelength can vary ±25 picometers (pm).
xx
1+ 25 pm See Table 2 for center wavelengths.
Side-mode
suppression ratio
SMSR 30 — — dB —
Transmitter
extinction ratio
OMI 9 — — dB —
Transmitter
optical output
power
Pout 0.0 — 3.0 dBm Average power coupled into single-mode
fiber
Receiver
Receiver optical
input wavelength
— 1530— 1565nm —
Receiver damage
threshold
—— —4.0 dBm—
Dispersion
tolerance
— –500— 1600ps/nm—
Power-Limited Performance (measured at optical signal-to-noise ratio [OSNR] of 30 dB at 0.1-nm RBW)
Optical input
power
Pin –23.0 — –7.0 dBm Measured at a bit error rate (BER) = 1E–12
with an IEEE 802.3 test pattern
Dispersion power
penalty
— — — 3 dB Measured at a bit error rate (BER) = 1E–12
with an IEEE 802.3 test pattern
Noise-Limited Performance (measured at OSNR of 24 dB at 0.1-nm RBW)
Optical input
power
Pin –18.0 — –7.0 dB Measured at a bit error rate (BER) = 1E–12
with an IEEE 802.3 test pattern
Dispersion
OSNR penalty
— — — 3 dB Measured at a bit error rate (BER) = 1E–12
with an IEEE 802.3 test pattern

10
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Overview
Table 8 Receiver Power Performance
Units Range Notes and Conditions
Long Wavelength Performances C Band, No-FEC Applications, Power-Limited
Input power range dBm –7 to –24 At BER = 1E–12 applicable at 9.9 G and 10.3 G,
30-dB OSNR (0.1-nm RBW)
Input power range dBm –7 to –22 At BER = 1E–12 (–500 to +1600 ps/nm)
applicable at 9.9 G and 10.3 G, 30-dB OSNR
(0.1-nm RBW)
Long Wavelength Performances C Band, No-FEC Applications, Noise-Limited
Input power range dBm –7 to –22 At BER = 1E–12 applicable at 9.9 G and 10.3 G,
26-dB OSNR (0.1-nm RBW)
Input power range dBm –7 to –20 At BER = 1E–12 (–500 to +1600 ps/nm)
applicable at 9.9 G and 10.3 G, 30-dB OSNR
(0.1-nm RBW)
Long Wavelength Performances C Band FEC Applications Noise-Limited
Input power range dBm –7 to –18 At BER PREFEC < 1E–5 applicable at 10.7 G and
11.1 G, 15.5-dB OSNR (0.1-nm RBW)
Input power range dBm –7 to –18 At BER PREFEC < 1E–5 (–500 to +1000 ps/nm)
applicable at 10.7 G and 11.1 G, 17-dB OSNR
(0.1-nm RBW)
Long Wavelength Performances C Band E-FEC Applications Power-Limited
Input power range dBm –7 to –27 At BER PREFEC < 7E–4 applicable at 10.7 G and
11.1 G, 26-dB OSNR (0.1-nm RBW)
Input power range dBm –7 to –26 At BER PREFEC < 7E–4 (–500 to +1300 ps/nm)
applicable at 10.7 G and 11.1 G, 26-dB OSNR
(0.1-nm RBW)
Long Wavelength Performances C Band E-FEC Applications Noise-Limited
Input power range dBm –7 to –20 At BER PREFEC < 7E–4 applicable at 10.7G and
11.1G, 12 dB OSNR (0.1-nm RBW)
Input power range dBm –7 to –20 At BER PREFEC < 7E–4 (–500 to +1300 ps/nm)
applicable at 10.7 G and 11.1 G, 14-dB OSNR
(0.1-nm RBW)

11
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Safety
Safety
Safety warnings appear throughout this publication in procedures that may harm you if performed
incorrectly or are ignored. A warning symbol precedes each warning statement.
Statement 1071—Warning Definition
Warning
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Use the statement number provided at the end of
each warning to locate its translation in the translated safety warnings that accompanied this
device.
SAVE THESE INSTRUCTIONS
Waarschuwing
BELANGRIJKE VEILIGHEIDSINSTRUCTIES
Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan
veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij
elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van de standaard
praktijken om ongelukken te voorkomen. Gebruik het nummer van de verklaring onderaan de
waarschuwing als u een vertaling van de waarschuwing die bij het apparaat wordt geleverd, wilt
raadplegen.
BEWAAR DEZE INSTRUCTIES
Varoitus
TÄRKEITÄ TURVALLISUUSOHJEITA
Tämä varoitusmerkki merkitsee vaaraa. Tilanne voi aiheuttaa ruumiillisia vammoja. Ennen kuin
käsittelet laitteistoa, huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu
onnettomuuksien yleisiin ehkäisytapoihin. Turvallisuusvaroitusten käännökset löytyvät laitteen
mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien
lausuntonumeroiden avulla.
SÄILYTÄ NÄMÄ OHJEET
Attention
IMPORTANTES INFORMATIONS DE SÉCURITÉ
Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant
entraîner des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez
conscient des dangers liés aux circuits électriques et familiarisez-vous avec les procédures
couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions des
avertissements figurant dans les consignes de sécurité traduites qui accompagnent cet appareil,
référez-vous au numéro de l'instruction situé à la fin de chaque avertissement.
CONSERVEZ CES INFORMATIONS

12
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Safety
Warnung
WICHTIGE SICHERHEITSHINWEISE
Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen
kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und
den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder
Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten
Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
BEWAHREN SIE DIESE HINWEISE GUT AUF.
Avvertenza
IMPORTANTI ISTRUZIONI SULLA SICUREZZA
Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle
persone. Prima di intervenire su qualsiasi apparecchiatura, occorre essere al corrente dei pericoli
relativi ai circuiti elettrici e conoscere le procedure standard per la prevenzione di incidenti.
Utilizzare il numero di istruzione presente alla fine di ciascuna avvertenza per individuare le
traduzioni delle avvertenze riportate in questo documento.
CONSERVARE QUESTE ISTRUZIONI
Advarsel
VIKTIGE SIKKERHETSINSTRUKSJONER
Dette advarselssymbolet betyr fare. Du er i en situasjon som kan føre til skade på person. Før du
begynner å arbeide med noe av utstyret, må du være oppmerksom på farene forbundet med
elektriske kretser, og kjenne til standardprosedyrer for å forhindre ulykker. Bruk nummeret i slutten
av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne
enheten.
TA VARE PÅ DISSE INSTRUKSJONENE
Aviso
INSTRUÇÕES IMPORTANTES DE SEGURANÇA
Este símbolo de aviso significa perigo. Você está em uma situação que poderá ser causadora de
lesões corporais. Antes de iniciar a utilização de qualquer equipamento, tenha conhecimento dos
perigos envolvidos no manuseio de circuitos elétricos e familiarize-se com as práticas habituais de
prevenção de acidentes. Utilize o número da instrução fornecido ao final de cada aviso para
localizar sua tradução nos avisos de segurança traduzidos que acompanham este dispositivo.
GUARDE ESTAS INSTRUÇÕES
¡Advertencia!
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes de manipular
cualquier equipo, considere los riesgos de la corriente eléctrica y familiarícese con los
procedimientos estándar de prevención de accidentes. Al final de cada advertencia encontrará el
número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña
a este dispositivo.
GUARDE ESTAS INSTRUCCIONES

13
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Safety
Varning!
VIKTIGA SÄKERHETSANVISNINGAR
Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada.
Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och
känna till vanliga förfaranden för att förebygga olyckor. Använd det nummer som finns i slutet av
varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna
anordning.
SPARA DESSA ANVISNINGAR

14
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Safety
Aviso
INSTRUÇÕES IMPORTANTES DE SEGURANÇA
Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há risco de lesões
corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os
circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes. Use o
número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de
segurança traduzidos que acompanham o dispositivo.
GUARDE ESTAS INSTRUÇÕES
Advarsel
VIGTIGE SIKKERHEDSANVISNINGER
Dette advarselssymbol betyder fare. Du befinder dig i en situation med risiko for
legemesbeskadigelse. Før du begynder arbejde på udstyr, skal du være opmærksom på de
involverede risici, der er ved elektriske kredsløb, og du skal sætte dig ind i standardprocedurer til
undgåelse af ulykker. Brug erklæringsnummeret efter hver advarsel for at finde oversættelsen i de
oversatte advarsler, der fulgte med denne enhed.
GEM DISSE ANVISNINGER

15
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Safety

16
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Safety
Warning
Because invisible laser radiation may be emitted from the aperture of the port when no cable is
connected, avoid exposure to laser radiation and do not stare into open apertures.
Statement 70
Warning
Class 1 laser product.
Statement 1008
Warning
Ultimate disposal of this product should be handled according to all national laws and regulations.
Statement 1040
Warning
Use of controls, adjustments, or performing procedures other than those specified may result in
hazardous radiation exposure.
Statement 1057

17
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Required Tools
Required Tools
You will need these tools to install the 10-Gigabit XFP transceiver modules:
•Wrist strap or other personal grounding device to prevent ESD occurrences.
•Antistatic mat or antistatic foam to set the transceiver on.
•Fiber-optic end-face cleaning tools and inspection equipment. For complete information on
inspecting and cleaning fiber-optic connections, see the white-paper document at this URL:
http://www.cisco.com/en/US/tech/tk482/tk876/technologies_white_paper09186a0080254eba.shtm
l
Installing the 10-Gigabit XFP Transceiver Module
Caution The XFP transceiver module is a static-sensitive device. Always use an ESD wrist strap or similar
individual grounding device when handling XFP transceiver modules or coming into contact with system
modules.
To install an XFP transceiver module, follow these steps:
Step 1 Remove the XFP transceiver module from its protective packaging.
Note Do not remove the optical bore dust plugs until directed to do so later in the procedure.
Step 2 Check the label on the XFP transceiver module body to verify that you have the correct model for your
network.
Step 3 Position the XFP transceiver module in front of the XFP socket opening on the line card. Slide the XFP
transceiver module part of the way into the transceiver socket on the line card front panel.
Step 4 Remove the optical bore dust plug from the XFP transceiver module.
Step 5 Pivot the bail clasp up so that it is parallel with the transceiver module body. (See Figure 2, top view.)
Step 6 Continue sliding the XFP transceiver module into the socket until the XFP transceiver module is mated
with the socket connector.
Step 7 Latch the XFP transceiver module in the transceiver socket by pivoting the bail clasp down so that the
bail clasp is perpendicular to the transceiver body. (See Figure 2, bottom view.)
Caution If the latch is not fully engaged, you may accidently disconnect the XFP transceiver module.
Step 8 Immediately reinstall the dust plug in the XFP transceiver module optical bores. Do not remove the dust
plug until you are ready to attach the network interface cable.

18
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Installing the 10-Gigabit XFP Transceiver Module
Figure 2 Installing the 10-Gigabit XFP Transceiver Module
Note 10-Gigabit XFP transceiver modules are keyed to prevent incorrect insertion.
Before removing the dust plugs and making any optical connections, follow these guidelines:
–
Keep the protective dust plugs installed in the unplugged fiber-optic cable connectors and the
transceiver optical bores until you are ready to make a connection.
–
Inspect and clean the LC connector end faces just before you make any connections. See the Tip
on this page for a pointer to a fiber-optic inspection and cleaning white paper.
–
Grasp the LC connector only by the housing to plug or unplug a fiber-optic cable.
a. Remove the dust plugs from the optical network interface cable LC connectors. Save the dust plugs
for future use.
b. Inspect and clean the LC connector’s fiber-optic end faces. See the Tip on this page for a pointer to
a fiber-optic inspection and cleaning white paper.
Tip For complete information on inspecting and cleaning fiber-optic connections, see this URL:
http://www.cisco.com/en/US/tech/tk482/tk876/technologies_white_paper09186a0080254eba.s
html
1
LINK
LINK ACTIVE
ACTIVE
2
1
LINK
LINK ACTIVE
ACTIVE
2
144376

19
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Removing the 10-Gigabit XFP Transceiver Module
c. Remove the dust plugs from the XFP transceiver module optical bores.
d. Immediately attach the network interface cable LC connectors to the XFP transceiver module. (See
Figure 3.)
Figure 3 Cabling a 10-Gigabit XFP Transceiver Module
Removing the 10-Gigabit XFP Transceiver Module
Caution The XFP transceiver module is a static-sensitive device. Always use an ESD wrist strap or similar
individual grounding device when handling XFP transceiver modules or coming into contact with
modules.
If you are removing an XFP transceiver, follow these steps:
Step 1 Disconnect the network interface cable from the XFP transceiver module connectors. Immediately
reinstall the dust plug in the fiber-optic cable LC connector.
Step 2 Pivot the XFP transceiver module bail clasp up to release the XFP transceiver module from the socket.
(See Figure 4, top view.)
Step 3 Slide the XFP transceiver module out of the socket. Pivot the bail clasp down and immediately install
the dust plug in the XFP transceiver module optical bores. (See Figure 4, bottom view.)
Step 4 Immediately place the XFP transceiver module in an antistatic bag.
1
LINK
LINK ACTIVE
ACTIVE
2
144377
Network interface
cable
LC connector
XFP transceiver

20
Cisco 10-Gigabit XFP Transceiver Modules Installation Note
OL-24246-01
Removing the 10-Gigabit XFP Transceiver Module
Figure 4 Removing the 10-Gigabit XFP Transceiver Module
1
LINK
LINK ACTIVE
ACTIVE
2
1
LINK
LINK ACTIVE
ACTIVE
2
144378
This manual suits for next models
45
Table of contents
Other Cisco Transceiver manuals

Cisco
Cisco QSFP-H40G-CU5M Installation and operation manual

Cisco
Cisco FM4200 Manual