From Flow Rate or Sensor Frequency screen, select to access menu.
Settings
X144D e-FlowMeter
Quick Start Programming
SETTINGS – VALVE (Adjust meter size and valve size parameters)
Note: Stylus Pen Recommended for Touch Screen Programming
VALVE
YES
Select then to configure meter size
VALVE YES
Select correct METER size from chart below
X144D Sizes 1 2 3 4
Full Port alve Sizes 2 2-1/2 3 4 6 8 10 12 14 16 18 20 24 30
Reduced Port alve Sizes 4 4 4 6 8 10 12 14 16 18 20 24 CF CF
YES Save configuration
SETTINGS – OUTPUT (Adjust Gain, mA Scaling, mA Filtering, Pulse Weight, and 4-20mA Output Test)
OUTPUT
YES
Select then to configure output.
OUTPUT YES
Default Gain is 1.00. Use arrow keys to adjust gain to desired value. Increasing or decreasing
value offsets factory calibration. Select to continue.
NEXT
Set the 20mA Value?
NEXT
002250.00
Use arrow keys to set 20mA Full Scale Output. Match 20mA value to customer display and/or
SCADA. Select to continue.
NEXT
Set Filter Strength
NEXT
4.0 width
Default Filter is 4.00. Use arrow keys to increase or decrease filtering of 4-20mA signal. The
higher the average filter strength, the longer the averaging time. Select to continue.
NEXT