manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Clarke
  6. •
  7. Fan
  8. •
  9. Clarke air CAM200 Installation and operation manual

Clarke air CAM200 Installation and operation manual

This manual suits for next models

5

Other Clarke Fan manuals

Clarke CONTRACTOR CON350 Instruction Manual

Clarke

Clarke CONTRACTOR CON350 Instruction Manual

Clarke Air CAM24 Instruction Manual

Clarke

Clarke Air CAM24 Instruction Manual

Clarke CAM30B Instruction Manual

Clarke

Clarke CAM30B Instruction Manual

Clarke Air CBF20 Instruction Manual

Clarke

Clarke Air CBF20 Instruction Manual

Clarke Air CAM36 Instruction Manual

Clarke

Clarke Air CAM36 Instruction Manual

Clarke CAM110 Instruction Manual

Clarke

Clarke CAM110 Instruction Manual

Clarke CAM30110V Instruction Manual

Clarke

Clarke CAM30110V Instruction Manual

Clarke CONTRACTOR CON500 Instruction Manual

Clarke

Clarke CONTRACTOR CON500 Instruction Manual

Clarke CBF20 Instruction Manual

Clarke

Clarke CBF20 Instruction Manual

Clarke CAM14HV Instruction Manual

Clarke

Clarke CAM14HV Instruction Manual

Clarke CDF20HV-B Installation and operation manual

Clarke

Clarke CDF20HV-B Installation and operation manual

Clarke CFF18C100 Instruction Manual

Clarke

Clarke CFF18C100 Instruction Manual

Clarke air movers Manual

Clarke

Clarke air movers Manual

Clarke CFF18B Instruction Manual

Clarke

Clarke CFF18B Instruction Manual

Clarke Air CAM900 Installation and operation manual

Clarke

Clarke Air CAM900 Installation and operation manual

Clarke CAM36C Instruction Manual

Clarke

Clarke CAM36C Instruction Manual

Clarke CAM20R Instruction Manual

Clarke

Clarke CAM20R Instruction Manual

Clarke CAM200B Instruction Manual

Clarke

Clarke CAM200B Instruction Manual

Clarke CAF304 Instruction Manual

Clarke

Clarke CAF304 Instruction Manual

Clarke CAM6000 Installation and operation manual

Clarke

Clarke CAM6000 Installation and operation manual

Clarke CPF18B100 Instruction Manual

Clarke

Clarke CPF18B100 Instruction Manual

Clarke CAM500 Instruction Manual

Clarke

Clarke CAM500 Instruction Manual

Clarke CSF2 User manual

Clarke

Clarke CSF2 User manual

Clarke Contractor CON305 Instruction Manual

Clarke

Clarke Contractor CON305 Instruction Manual

Popular Fan manuals by other brands

Minka Group minkaAire Wave F843 instruction manual

Minka Group

Minka Group minkaAire Wave F843 instruction manual

Airflow Adroit DV50 instruction manual

Airflow

Airflow Adroit DV50 instruction manual

Vornado 270 Series owner's guide

Vornado

Vornado 270 Series owner's guide

comfort air TH-10D instruction manual

comfort air

comfort air TH-10D instruction manual

Livoo DOM386 instruction manual

Livoo

Livoo DOM386 instruction manual

Holmes BLIZZARD HAOF-90 owner's guide

Holmes

Holmes BLIZZARD HAOF-90 owner's guide

Taurus GRECO 16 ELEGANCE manual

Taurus

Taurus GRECO 16 ELEGANCE manual

Quorum PINNACLE installation instructions

Quorum

Quorum PINNACLE installation instructions

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Craftmade UH52 installation guide

Craftmade

Craftmade UH52 installation guide

Jocel JVA030658 instruction manual

Jocel

Jocel JVA030658 instruction manual

MIKA MFB1211/GR user manual

MIKA

MIKA MFB1211/GR user manual

Harbor Breeze RLG52NWZ5L manual

Harbor Breeze

Harbor Breeze RLG52NWZ5L manual

Allen + Roth L1405 instruction manual

Allen + Roth

Allen + Roth L1405 instruction manual

ViM KUBAIR F400 ECOWATT Technical manual

ViM

ViM KUBAIR F400 ECOWATT Technical manual

HIDRIA R10R-56LPS-ES50B-04C10 user guide

HIDRIA

HIDRIA R10R-56LPS-ES50B-04C10 user guide

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

BLAUBERG Ventilatoren

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

Triangle Engineering HEAT BUSTER SPL Series owner's manual

Triangle Engineering

Triangle Engineering HEAT BUSTER SPL Series owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

OPERATING & MAINTENANCE
INSTRUCTIONS
VENTILLATOR
Part Nos. 3230440• 3230450• 3230460
1205
VENTILLATOR
OPERATION
The fan is operated by the ON/OFF switch located in the handle.
The unit may be used for either extracting dirty air or for supplying fresh air, as
desired. Simply attach the ducting to the appropriate end of the machine, as
shown, secured with the cord attached.
MAINTENANCE
WARNING : Disconnect from mains before attempting any maintenance work.
Periodically clean guards and fan blades by vacuuming or wiping. Remove guard
to gain access to blade.
REPLACE ALL GUARDS BEFORE RE-CONNECTING FAN TO MAINS SUPPLY.
For Spare Parts and Service, please contact your nearest dealer,
or CLARKE International, on one of the following numbers.
PARTS & SERVICE TEL: 020 8988 7400
or e-mail as follows:
PARTS: [email protected]
SERVICE: [email protected]
4
PARTS AND SERVICE CONTACTS
SPECIFICATIONS
CAM200 CAM250 CAM300
Air Inlet Size ......... 8inch ....................... 10inch ........................ 12inch
Motor .................. 230V~ 50Hz 1Ph ..... 230V~ 50Hz 1Ph ......... 230V~ 50Hz 1Ph
Power Rating ...... 165Watts ................. 250Watts .................... 392Watts
Fuse Rating ......... 13 Amps .................. 13Amps ...................... 13Amps
Air Flow ................ 838ft3/min ............... 1284 ft3/min ................ 2070 ft3/min
Net Weight ......... 8.5kg ....................... 10kg ............................ 15.5kg
Sound Press Level . 76dB(A) ................... 83dB(A) ....................... 86dB(A)
Part No. ............... 3230440 .................. 3230450 ...................... 3230460 Model Nos.
CAM200 • CAM250 • CAM300
ELECTRICAL CONNECTIONS
Connect the mains lead to a standard, 240 Volt (50Hz) electrical supply through an
approved 13 amp BS 1363 plug, or a suitably fused isolator switch.
WARNING! THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in the mains lead are coloured in accordance with the
following code:
Green & Yellow - Earth
Blue - Neutral
Brown - Live
As the colours of the flexible cord of this appliance may not correspond with the
coloured markings identifying terminals in your plug proceed as follows:
• Connect GREEN & YELLOW cord to plug terminal marked with a letter “E” or
Earth symbol “ ” or coloured GREEN or GREEN & YELLOW.
• Connect BROWN cord to terminal marked with a letter “L” or coloured RED
• Connect BLUE cord to terminal marked with a letter “N” or coloured BLACK
If this appliance is fitted with a plug which is moulded onto the electric cable (i.e.
non-rewirable) please note:
1. The plug must be thrown away if it is cut from the electric cable. There is a
danger of electric shock if it is subsequently inserted into a socket outlet.
2. Never use the plug without the fuse cover fitted.
3. Should you wish to replace a detachable fuse carrier, ensure that the correct
replacement is used (as indicated by marking or colour code).
4. Replacement fuse covers can be obtained from your local dealer or most
electrical stockists.
5. The fuse in the plug must be replaced with one of the same rating (5 amps)
and this replacement must be ASTA approved to BS1362.
We recommend that this machine is connected to the mains supply through a
Residual Current Device (RCD).
If in doubt, consult a qualified electrician. Do not attempt any electrical repairs
yourself.
3
Thank you for purchasing this CLARKE Ventillator, which is designed for indoor use in
an industrial environment.
Please read this leaflet thoroughly and follow the instructions carefully, in doing so
you will ensure the safety of yourself and that of others around you, and you can
look forward to the Ventillator giving you long and satisfactory service.
SAFETY PRECAUTIONS
Before using the fan, please ensure that you read and observe the following safety
rules. It is also important that other people in the vicinity are made aware of, and
made to comply with, these rules:-
1. Do not operate the Ventillator with any guards removed.
2. Do not allow loose clothing, long hair, jewellery etc. to be drawn into the
intake side of the Ventillator.
3. Keep children and animals away from the Ventillator when in operation.
4. Do not operate in wet/damp environment, and ensure that the unit is not
sited where it is possible for water to be drawn into the intake. Be aware that
the suction capability is considerable at higher fan speeds.
5. Do not position fan where it will blow dust, chips or hazardous fumes at people
in the path of the air flow.
6. Do not exert any strain on the power cable, and check the condition of the
cable before operating the fan. Replace if damaged.
7. Disconnect the Ventillator from the power source before moving or attempting
any kind of service work whatsoever.
8. Do not operate the Ventillator near flammable liquids or in gaseous or explosive
atmospheres.
GUARANTEE
This CLARKE product is guaranteed against faulty manufacture for a
period of 12 months from the date of purchase. Please keep your receipt
as proof of purchase.
This guarantee is invalid if the product is found to have been abused or
tampered with in any way, or not used for the purpose for which it was
intended.
Faulty goods should be returned to their place of purchase, no product
can be returned to us without prior permission.
This guarantee does not effect your statutory rights.
2