Clarson PUBLIC IV User manual

PUBLIC IV
Intercom Ceiling LED
Service and Installaon Instrucons
Key funcons, LED signals.........................................................................................................................10
PTT mode..................................................................................................................................................10
Service sengs.........................................................................................................................................11
Volume control.........................................................................................................................................11
External connecons for headset, audio player, audio recorder..............................................................11
Installaon instrucons .......................................................................................................................... 4/5
Installaon intercom .............................................................................................................................. 6/7
Installaon intercom with footswitch..................................................................................................... 8/9
Installaon microphone ......................................................................................................................... 7/9
Installaon loudspeaker ......................................................................................................................... 7/9
• Open duplex
• Push-to-talk
• Headset interface
• Speech key control via footswitch
• Music input
• Recording possibility
• AEC (Automac echo cancellaon)
• NR (Noise reducon)
• NG (Noise gate)
• Individual volume control for loudspeaker / microphone/ headset /
audio via +/- keys
• Balanced microphone inputs
Voltage/power...................................................................................................................... 15VDC/700mA
Maximum power consumpon (limited by power supply) ................................................................ <15W
Power consumpon in OFF-mode................................................................................................... <0.15W
Maximum output impedance (no connuous operaon) at 8Ω/channel .............................................. 5W
Minimum loudspeaker impedance.......................................................................................................... 8Ω
Audio IN-input level/input impedance ...................................................................................30mV(1)/47kΩ
REC OUT-output level/output impedance..............................................................................20mV(2)/10kΩ
Temperature :................................................................................................................................10 - 40 °C
Humidity:.....................................................................................................20 % to 75 % (non condensing)
Air pressure: ................................................................................................................700 hPa to 1060 hPa
(1)Connect Audio IN to the headphone jack of the audio source.
Tune output level of the audio source in such a way that in case of maximum volume overmodulaon of the intercom system
is avoided.
(2)This value depends on the volume set, on the speech volume and on the distance to the microphone. 35.054.440.007 07/2020
Table of Contents
Features
Technical Data

23
(3)For AX the footswitch is included in the delivery of the intercom system and should be connected.
For XP the footswitch can be obtained as an oponal accessory.
Footswitch STEUTE KF 1S
with 2m cable and RJ45 plug
Labels 32.054.065.002, 32.054.040.001
Delivery Contents Footswitch(3)
RJ45 connector, label 32.054.009.004 40.054.841.002
Audio cable, 2m (2x)
Loudspeaker cable KAT5e, 20m
Labels 32.054.043.001, 32.054.043.002
40.054.843.001
11.054.02
40.054.819.002
Microphone extension cable KAT5e, 20m
Labels 32.054.045 .001 and 32.054.045.002
40.054.842.001
Surface mounted loudspeaker 6W / 20Ω
colour RAL 9010, labels 32.054.005.004, 32.054.062
cable outlet top/boom (40.006.174)
40.006.173.002
Intercom console
colour RAL 7035
labels 32.054.015.004, 32054013002_ETL
40.054.440.005
Delivery Contents Intercom System
Omnidireconal microphone EM 258 in ABS housing
colour RAL 9010, LED-Ring, label 32.054.007.004,
1m cable with RJ45 plug 40.054.470, label
32.054.046.001, wall/ceiling holder 40.005.094,
cover plate 06.054.06
Power cable EU, 2m
labels 32.054.032.001, 32.054.032.002
40.054.834.001
Power cable USA, 2m
labels 32.054.032.001, 32.054.032.002
40.054.835.001
Power cable UK, 2m
labels 32.054.032.001, 32.054.032.002
40.054.836.001
Primary adapter ROW 08.052.05.001
Patch cable KAT5e, 3m
labels 32.054.036.001, 32.054.036.002
FOX12 Medical Power Supply, 100-240V /50-60Hz, 1.8m
cable, labels 32.054.803.003, 32.054.008.004
~
Connecon Hub
label 32.054.014.004
40.054.443.003
40.005.171.001
40.054.803.004
40.054.327.002

5
Posioning of the Components Microphone, Loudspeaker and Intercom Console
Loudspeaker
- Mounng on the ceiling above the user,
or on the wall below the ceiling behind the user
Intercom Console
- the intercom console has to be placed as far from the
control room door as possible
Maximum speech distance to the microphone: 10cm
Microphone
- ceiling xaon
- as close to the user´s working posion as possible
- avoid collision with other components suspended from the ceiling
4
U
2x C H
N
Service and Installaon Instrucons
German
English
Mounng material for microphone ceiling xaon:
drilling template
2 counter-sunk head screws 3,5x30mm + 2 wall plugs
5x25mm
Mounng material for connecon hub
1 hook-and-loop fasteners(4)
Mounng material for loudspeaker
4 screws 3,5x35mm, 4 wall plugs 5x25mm
2 screws 2,9x16mm, 2 decorave caps
cable es 100mm
Mounng material for power supply
hook-and-loop fastener(4)
V
Delivery Contents Mounng Material
((4)Use hook-and-loop fasteners only on suitable surfaces (adhesion)!
35.054.440.006
35.054.440.007
35.054.006
40.054.844
40.054.830.001
40.054.827
40.054.831
40.054.832
40.054.830.002
6 5
3 8
5
J

67
Control Room
Intercom System
without footswitch
4
H
C
C
N
Installaon Loudspeaker
Paent´s Room
20m
20m
1m
3
3a
> Intercom Speaker
< Intercom Connecon Hub (3)
> Intercom Connecon Hub (3)
< Intercom Speaker
4
4a
2m
3m
2
2a
1b
4a
3b
> Intercom Power Supply
< Intercom Cleaner Socket
> Intercom Cleaner Socket
< Intercom Power Supply
> Intercom Connecon Hub (1)
< Intercom Console (1)
> Intercom Console (1)
< Intercom Connecon Hub (1)
1
1a
2
2a
> Intercom RJ45 Connector (1)
< Intercom Microphone
3
> Intercom R45 Connector (2)
< Intercom Connecon Hub (2)
3a
> Intercom Connecon Hub (2)
< Intercom R45 Connector (2)
3b
> Intercom Connecon Hub (6)
(DC Power)
< Intercom Power Supply
15V /700mA
1b
Ceiling installaon microphone
6 5
3 8
5
drilling template
J
Important for Installaon Planning:
Dimensions microphone cable :
Length 1m, Ø 3,1mm
Extension cable length 20m, Ø 5,5mm
Clearance hole for RJ45 connector
minimum Ø16mm.
Observe drilling template!
Dimensions loudspeaker cable:
Length 20m, Ø 5,5mm
Clearance hole for RJ45 connector
minimum Ø17mm.
Dimensions mounng material
see page 4
Wandsteckdose
100-240V
50-60Hz
~
wall socket
100-240V
50-60Hz
~
No other power supply than the one tested and appro-
ved by Clarson must be used.
1a
1

98
Control Room
Intercom system
with footswitch
2m
3m
2m2
2a
1b
4a
3b
5
> Intercom Power Supply
< Intercom Cleaner Socket
> Intercom Connecon Hub (6)
(DC Power)
< Intercom Power Supply
15V /700mA
> Intercom Cleaner Socket
< Intercom Power Supply
> Intercom Connecon Hub (1)
< Intercom Console (1)
> Intercom Console (1)
< Intercom Connecon Hub (1)
1
1a
1b
2
2a
> Intercom RJ45 Connector (1)
< Intercom Microphone
3
> Intercom R45 Connector (2)
< Intercom Connecon Hub (2)
3a
> Intercom Connecon Hub (2)
< Intercom R45 Connector (2)
3b
Wandsteckdose
100-240V
50-60Hz
~
wall socket
100-240V
50-60Hz
~
No other power supply than the one tested and appro-
ved by Clarson must be used.
1a
1
4
H
C
C
N
Installaon Loudspeaker
Paent´s Room
20m
20m
1m
3
3a
> Intercom Speaker
< Intercom Connecon Hub (3)
> Intercom Connecon Hub (3)
< Intercom Speaker
4
4a
Ceiling installaon microphone
6 5
3 8
5
drilling template
J
Important for Installaon Planning:
Dimensions microphone cable :
Length 1m, Ø 3,1mm
Extension cable length 20m, Ø 5,5mm
Clearance hole for RJ45 connector
minimum Ø16mm.
Observe drilling template!
Dimensions loudspeaker cable:
Length 20m, Ø 5,5mm
Clearance hole for RJ45 connector
minimum Ø17mm.
Dimensions mounng material
see page 4
> Intercom Connecon Hub (4)
< Footswitch (4)
5

10
The volume can only be changed if either or or is switched on.
PTT Mode:
Push and hold key to switch the microphone on.
Aenon: transmission only takes place when the LED is acvated.
Switching on PTT Mode:
Switch the intercom system o
Push and hold key (approx. 5 sec.) unl LED above ashes.
Switching o PTT Mode:
Switch the intercom system o
Push and hold key (approx. 5 sec) unl LED above ashes.
Intercom Console
The corresponding LEDs indicate the operang state of the intercom system. Should external distur-
bances such as prolonged voltage drops change the operang status, the original state can be restored
via control panel.
Key Funcons, External Connecons and LED Signalling
Key Funcon LED State System Operang Status
Intercom System ON/OFF on ready for use
o switched o
ashes set-up mode
Loudspeaker ON/OFF on loudspeaker ON
o loudspeaker OFF
Microphone ON/OFF on microphone ON
o microphone OFF
Audio IN ON/OFF on Audio IN ON
o Audio IN OFF
Increase volume led brightens
ashes maximum volume
Reduce volume led darkens
ashes minimum volume
11
Connecon for audio recorder(5)
Connecon for audio player(5)
Connecon for headset(5) (6)
Aer switching on the intercom system the intercom console is acvated, regardless of whether the
headset microphone is plugged in or not.
Switchover to headset operaon is made by removing and re-inserng the headset microphone plug.
Operaonal Start-up/Service(7)
External Connecons Intercom Console
External Connecons Central Unit
(5)Not included in scope of supply
(6)Contact Clarson directly for suitable headsets
(7)Unplug or plug in patch cable only in power-free state
To avoid poor sound quality and feedback, it may be necessary to adjust the volume range sengs to
accomodate the acousc condions on site.
Maximum volume for both the Control Room and the Paent´s Room is set as follows:
Firstly, PTT turned on (state of delivery), ensure all doors between Control Room and Paent´s Room
are open.
Press the buon to switch the intercom system o, all LEDs will turn o.
Press the key sequence , the LED above the buon ashes.
Press the buon, the LED above the buon lights up.
Use the and buons to set the maximum volume for an opmal sound quality at the
Control Room .
Press the buon, the LED above the buon turns o.
Press and hold the buon, the LED above the buon lights up.
Use the and buons to set the maximum volume for opmal sound quality at the
Paent´s Room .
Release the buon, the LED above the buon turns o.
Press the and buons to the same me unl LEDs above the buons ash briey once
to save the new values.
Press the and buons to the same me unl LEDs above the buons
lights up | ashes | lights up, to reset to factory sengs.
Press the buon to exit the sengs, all LEDs will turn o.
Trouble shoong:
In case of interference, intercom components should be relocated to increase the distance from
sources of strong electromagnec radiaon.
Other Clarson Intercom System manuals