• For working environment contaminated by both
kinds of pollution it is necessary to use combined
lters.
• For gases which are difcult to identify it is ne-
cessary to follow special rules.
• Replace the lters whenever there is an odour
change on the air coming into the headtop.
• Useonlycertiedoriginalltersdeterminedforyour
powered respiratory unit.
CAUTION! Violation of any precepts for usage of
your powered respiratory unit automatically annuls
the Warranty!
3. Unpacking / Assemblage /
Usage and Functions
3.1. Unpacking the CA Chemical 2F/3F
Check whether the consignment is complete and if no-
thing has been damaged during transport.
The complete system including accessories contains
the following components:
1. Powered respiratory unit 1 pc
2. Battery 1 pc
3. Belt 1 pc
4. Air supply hose 1 pc
5. Flow indicator 1 pc
6. Battery charger 1 pc
7. Manual for use 1 pc
3.2. Assemblage
1. Connect the air supply hose to the powered re-
spiratory unit making sure the screw is tight enough
so the joint is leakproof.
2.Attachthelterstotheunit-alwaysallofthesame
type!
3. Connect the hose to the headtop.
Basic description of usage and functions
CA CHEMICAL 3F Plus
The unit can be switched on by pressing any of the two
controllingpush-buttonsshortly.Individualowlevels
can be changed by shortly pressing buttons and .
Instantly after switching the unit on you can see infor-
mation about the supplier of your powered respiratory
uniton the display; during the second visualdisplay,
you can go over to the MENU by pressing both buttons
at the sane time for 2 seconds; last the information
display will visualize giving you the following informa-
tion: the actual ow level, the present state of lter
cloggingandofbaterrycharging.Forbetterorientation,
these specications are distinguished by correspon-
dent pictograms.
The Flow Control System keeps the air-ow steady
irrespectiveoftheltercloggingorthedegreeofba-
ttery charging.
Ifitisimpossibletokeepthechosenair-ow,youwill
hear an acoustic signal. If it is possible, the electro-
nicswill automatically decrease theair-owby one
level. If the unit is unable to keep the lowest practicable
air-ow, youwill be warnedbyalarm andthereason
for this alarm as well as the instructons for needful
intervention into the unit will appear on the display.
Next it is urgent to stop work immediatelly and to repla-
cethelterorbattery,eventuallytochargethebattery.
CA CHEMICAL 2F Plus
The unit can be switched on by pressing any of the two
controllingpush-buttons.Individualowlevelscanbe
changed by shortly pressing buttons and . Instant-
ly after switching the unit on you can see information
about the supplier of your powered respiratory unit on
thedisplay;duringthesecondvisualdisplay,youcan
go over to the MENU by pressing both buttons at the
same time for 2 seconds ; last the information display
will visualize giving you the following information: the
actual ow level, the present state of lter clogging
andofbaterrycharging.Forbetterorientation,these
specications are distinguished by correspondent
pictograms. The Flow Control System keeps the
airowsteadyirrespectiveoftheltercloggingorthe
degree of battery charging.
Ifitisimpossibletokeepthechosenair-ow,youwill
hear an acoustic signal. If it is possible, the electro-
nicswill automatically decrease theair-owby one
level. If the unit is unable to keep the lowest practicable
air-ow,youwillbewarnedbyalarmandthereasonfor
this alarm as well as the instructions for needful inter-
vention into the unit will appear on the display. Next it
is urgent to stop work immediatelly and to replace the
lterorbattery,eventuallytochargethebattery.
Detailed description of functions for units 2F Plus
and 3F Plus
Monitoring panel – displays
selected standard, type of lter
in use, remaining and set alarm
time, present ow volume, the
presentstateofltercloggingand
battery charging.
Alarm – alarm informing the
user about unsatisfactory air-
-owthroughtheunitduetolter
clogging. It is vital to leave the
contaminated area and replace
lters.
Alarm – alarm notifying the user
of the lter expiry which can be
pre-set. The alarm is also repre-
-sented by a red LED located
next to the display.