ALPHA SERIES
TREATMENT TABLES
MODELS 3010, 3020, 3030, 3013,
with ADJUSTABLE BACKREST
or NON-ADJUSTABLE TOP
ASSEMBLY INSTRUCTIONS
ASSEMBLY INSTRUCTIONS FOR ALPHA SERIES TREATMENT TABLES
MODELS 3010, 3020, 3030 & 3013 with ADJUSTABLE BACKREST/KD & Tables with Pre-Attached Backrest
For MODELS 3010, 3020, 3030 & 3013 with NON-ADJUSTABLE TOP and PRE-ATTACHED TOPS Skip STEPS 5,through 9
MAXIMUM WEIGHT CAPACITY 450 LBS
14
2
3
Open the frame box, remove all packaging and
position the table frame upside down on a soft
surface that won't mar the top. Position the legs
up as shown below.
Spin the 4 adjustable feet into the legs. With
assistance, invert the table into an upright
position on all four legs, using caution when
inverting the end with the adjustable headrest.
Use the hardware and tools provided
to secure the legs into a locked
position using the
1/4-20 x 1 ½" hex bolts
and 1/4" locknuts.
DO NOT to tighten at this time.
Attach the spanner between the two legs
using the
1/4-20 x 1" hex bolts
and wrench
provided and completely tighten all 12 frame
connecting hardware points from step 2
Thank you for counting on Clinton to meet your medical
equipment needs by purchasing this fine equipment. All
Clinton equipment is designed and manufactured to
provide years of dependable service because we want you
as a customer now and in the future. Below are easy to follow
instructions on how to properly assemble your equipment.
Please contact us at 800-441-9131 if you experience any
difficulty with the assembly or have questions.
INTENDED USE
Clinton treatment tables, models 3010, 3020, 3030 &
3013, are specifically designed and engineered for the
use by a single person at a time, who is attended to and
observed by trained medical personnel. Never leave
anyone on the table unattended. Person’s weight and the
combination of force exerted on the table during treatment
is not to exceed a total of 450 lbs.
Hardware Package
(4) 1/4-20 x 1 ½" Hex Bolts (4)
(4) 1/4-20 x 1" Hex Bolts (4)
(2) 1/4-20 x 1" Truss Head Screws (0)
(4) 1/4-20 x 2 5/8" Truss Head Screws (0)
(2) 1/4-20 x 1" Truss Head Bolts (0)
(8) 5/16" Washers (4)
(6) 5/16" Locknuts (0)
(4) 1/4" Locknuts (4)
(4) 11/4" Black
Truss Head Screws
(3030 & 3013) (4)
KD
Quantity
Pre-Attached
Quantity
Tools Required
Wrench & (2) Allen Wrenches Provided
Phillips Screwdriver and Adjustable Wrench (not provided)
6
57
8
9
Loosely fasten the adjustable backrest hinge to
the frame’s cross member using (4) 1/4-20 x
1 ½" hex bolts, two 5/16" washers (one each side)
and 5/16" locknuts. Note: Hinge flap goes on the black
channel side.
Place the black backrest channel on top of the
frame tabs with the channel cutouts close to
the head end. Secure using (2) 1/4-20 x 1" truss
head screw and
5/16 "
locknut at each end.
Mount the foot end of the top by placing the
(4) 1/4-20 x 2 5/8" truss head
screws through the frame sides
and the (2) 1/4-20 x 1" truss head screws and
5/16" washers at the end mounting points and
tightly securing the top. Fully tighten hinge
hardware from Step 6.
Secure all screws in the frame
Secure the middle brace to the top
FOR SAFETY PURPOSES, TAKE TIME TO CHECK ALL SCREWS, BOLTS AND NUTS TO INSURE THAT
THEY ARE SECURELY TIGHTENED AND THAT THE TABLE HAS BEEN PROPERLY ASSEMBLED
ACCORDING TO THESE INSTRUCTIONS.
PROCEED TO STEPS 10, 11 & 12 ON BACK COVER FOR MODELS 3020, 3030 & 3013
FOR MODELS WITH ADJUSTABLE BACKREST FOR MODELS WITH ADJUSTABLE BACKREST
FOR MODELS WITH ADJUSTABLE BACKREST
FOR MODELS WITH ADJUSTABLE BACKREST
FOR MODELS WITH ADJUSTABLE BACKREST
3030 TIER SHELF ASSEMBLY
With table in the upright position, place the
full-length shelf into position under the table
(see step 10). Using assistance, place tier shelf on the full
shelf, aligning it with the end of the shelf that has the
pre-drilled holes. (See photo below)
800-441-9131 • 717-848-3519
Toll-Free Fax 866-522-1233
Fax 717-843-5871
www.clinton-ind.com
© Copyright 2013, Clinton Industries, Inc. CLI-MA-013
Clinton Industries warrants manufactured products to be free of defects in materials, workmanship or design
under normal use for five years on all mechanical products and two years on all electrical components from
the date of purchase. This warranty does not include damage resulting from accident, abuse or misuse, alteration, or
negligence of the product and expressly excludes normal wear of parts (including but not limited to vinyl). Contact
Clinton for full warranty details. ANY ALTERATIONS TO OUR PRODUCTS VOIDS ALL WARRANTIES AND CLAIMS.
Warranty
Clinton products are built to be durable. With proper care, your Clinton equipment will provide years of
superior looks and performance. Clean table with a soft cloth and any mild cleaning agent that may be required for
sanitation. NEVER use abrasive scrubbing agents that may scratch the surfaces. Before using any cleaning agents,
try them on a small inconspicuous area to insure that they will not harm the any surface.
Damage from cleaning is not covered under the warranty. Do not use alcohol based cleaning agents.
Periodically check that all fasteners are secure and operating properly.
Care & Cleaning
11
12 3013 DRAWER ASSEMBLY
With table in the upright position, place the full-
length shelf into position under the table (see
step 10). Remove the drawers and place the drawer casing
into position aligning it with the end of the shelf that has
the pre-drilled holes. Fasten unit by screwing the supplied
1 1/4” black truss head screws through shelf and into
pre-inserted, threaded inserts. (See photo below).
MODELS 3013
MODEL 3030
10 3020 SHELF ASSEMBLY
Invert table to upright position and apply 4
adhesive backed hook and loop strips to top
edge of H-braces. Place the full-length shelf on the spanner
with the loop strip underside over the hook strips on the
braces.
Adhesive-backed hook strips
Limited Warranty
ON FRAME &
ELECTRICAL
COMPONENTS
Limited
Warranty

This manual suits for next models

4

Other Clinton Medical Equipment manuals

Clinton 84100 User manual

Clinton

Clinton 84100 User manual

Clinton 6198 User manual

Clinton

Clinton 6198 User manual

Clinton 85100 Maintenance manual

Clinton

Clinton 85100 Maintenance manual

Clinton 6361 User manual

Clinton

Clinton 6361 User manual

Popular Medical Equipment manuals by other brands

Synthes LCP Surgical Technique Guide

Synthes

Synthes LCP Surgical Technique Guide

Otto Bock 13E205 Instructions for use

Otto Bock

Otto Bock 13E205 Instructions for use

Opticlar VisionMed D-Scope Instructions for use

Opticlar VisionMed

Opticlar VisionMed D-Scope Instructions for use

Ferno 125 user manual

Ferno

Ferno 125 user manual

FujiFilm FDR D-EVO II Operation manual

FujiFilm

FujiFilm FDR D-EVO II Operation manual

Westfalia 18 30 53 instruction manual

Westfalia

Westfalia 18 30 53 instruction manual

Masimo Red DCI manual

Masimo

Masimo Red DCI manual

Sedecal Rad Room Service manual

Sedecal

Sedecal Rad Room Service manual

natus neoBLUE mini Service manual

natus

natus neoBLUE mini Service manual

Pressalit Care R1081 Mounting instruction

Pressalit Care

Pressalit Care R1081 Mounting instruction

Winco TransMotion TMM4 Installation and usage instructions

Winco

Winco TransMotion TMM4 Installation and usage instructions

Invacare MicroAIR MA50 user manual

Invacare

Invacare MicroAIR MA50 user manual

PROVOX Life quick start guide

PROVOX

PROVOX Life quick start guide

mychway YH-6505 user manual

mychway

mychway YH-6505 user manual

medi Classic Instructions for use

medi

medi Classic Instructions for use

Real WSM user manual

Real

Real WSM user manual

Interacoustics Affinity2.0 Instructions for use

Interacoustics

Interacoustics Affinity2.0 Instructions for use

Siem Nova 1001 NEB manual

Siem Nova

Siem Nova 1001 NEB manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.