8 Johnson Controls Ducted Systems
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
APPLICATIONS AND ACCESSORIES
Refer to Price Manual for specific model numbers.
* For Low Ambient and/or Long Lineset Applications, please see the acces-
sories listed below.
Non-Standard Lineset Applications - For installations with
reduced diameter or long linesets, refer to the current version of
the Piping Application Guide P/N 247077, available in the Appli-
cation Bulletins section on www.simplygettingthejobdone.com.
OD Unit Anti Short Cycle Kit (10 Pack) S1-2TD08700124BK:
A time delay that prevents rapid compressor restarting as a
result of power interruption, limit switch operation, or thermostat
resetting. Not required for HP models, or for AC models with
factory electronic controls.
Standard Low Ambient Control Kit S1-2LA06700424: Allows
the use of air conditioning at low outdoor ambient temperatures
down to +20°F (-7°C). For use with all R-410A single stage AC
& HP models.
Advanced Low Ambient Control Kit S1-2LA04701024: Con-
tains the necessary components and controls to allow cooling
operation down to -20ºF (-29ºC). For use with some R-410A
single stage AC & HP models. This accessory can only be
applied to models that contain a PSC outdoor fan motor.
Low Pressure Switch Kit S1-2PS06700524: Provides field
installed low pressure (loss of charge) protection. Not required
for HP models, or for AC models with factory electronic con-
trols.
High Ambient Outdoor Fan Motor S1-FHM****HT: Class F
70°C motor to allow cooling operation up to 160ºF air entering
the outdoor coil. For use with all R-410A single stage AC & HP
models containing R-410A refrigerant only.
Outdoor Communicating Board Kit (S1-33102952310): Elec-
tronic control upgrade for standard AC units to provide compati-
bility with the Residential Touch Screen Communicating
Control.
Compressor Crankcase Heater Kit (S1-025-*****-***): A
wrap-around electrical resistance heater that warms the com-
pressor sump, reducing the chance of liquid slugging on
startup. Required on all long lineset and low ambient applica-
tions. See Price Pages or Source1 SmartSearch for the correct
part for each application.
Indoor TXV Kit S1-1TVM***: Thermal expansion valves pre-
cisely meter refrigerant for optimum performance over a wide
range of conditions. See System Charge Table, Price Pages, or
Source1 Smart Search for TXV part number for each AC & HP
model.
Cold Weather Charging Tent S1-CHGTENT01: Provides
warm environment to accurately service AC & HP systems in
ambient conditions 55ºF (13ºC) or colder.
Touch-up Paint S1-5130153****: Color matched aerosol paint
for touching up unit chassis and panels. See Price Pages or
Source1 SmartSearch for the correct color for each application.
Compressor Sound Blanket S1-0100764*000: A field
installed dense foam cover that provides 2dBA sound level
reduction. See Price Pages or Source1 SmartSearch for the
correct blanket for each application.
Thermostat: Compatible thermostat controls are available
through accessory sourcing. For optimum performance, these
outdoor units are fully compatible with our Coleman Hx™
Touchscreen Thermostats available through Source1. For more
information, see the thermostat section of the Product Equip-
ment Catalog.
SOUND POWER RATINGS
Rated in accordance with ARI Standard 270.
TCHE48S4(3,4)S1 CP9C120D20MP13C 24.5 FC49D 1200 45.5 32.0 15.10 12.50
TCHE48S4(3,4)S1 CPLC080C16MP12C 21.0 FC49D 1425 46.0 34.4 14.25 12.00
TCHE48S4(3,4)S1 CPLC080C16MP13C 21.0 FC49D 1200 45.5 32.2 14.75 12.25
TCHE48S4(3,4)S1 CPLC100C16MP12C 21.0 FC49D 1425 46.0 34.4 14.25 12.00
TCHE48S4(3,4)S1 CPLC100C16MP13C 21.0 FC49D 1200 45.5 32.2 14.75 12.25
TCHE48S4(3,4)S1 CPLC100C20MP12C 21.0 FC49D 1425 46.0 34.2 15.00 12.50
TCHE48S4(3,4)S1 CPLC100C20MP13C 21.0 FC49D 1225 45.5 32.4 15.00 12.50
TCHE48S4(3,4)S1 CPLC120C20MP12C 21.0 FC49D 1425 46.0 34.2 15.00 12.50
TCHE48S4(3,4)S1 CPLC120C20MP13C 21.0 FC49D 1225 45.5 32.4 15.00 12.50
For rated condition information, see the footnotes below the System Capacity - Single Piece and Modular Air Handlers table.
1. High Efficiency Motor Furnaces have B.O.D (Blower Off Delay) standard.
2. CM coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With High Efficiency Motor Furnaces1(Continued)
UNIT
MODEL
FURNACE COIL
MODEL2
COOLING
MODEL WIDTH RATED
CFM NET MBH SEER EER
TOTAL SENS.
Standard Application Limits*
Maximum Lineset Equivalent Length 200 Ft
Outdoor Ambient Temperature Limits
Cooling Operation Maximum DB 120°F
Minimum DB 50°F
Cooling Octave Band Sound Power Level (db re. 1-pW)
Model Number 63 125 250 500 1000 2000 4000 8000 dBA
TCHE36S4(3,4)S11 74 77 68 67 66 61 58 58 71
TCHE48S4(3,4)S11 75 81 70 68 66 61 58 58 72