GETTING STARTED
Color Kinetics
®
PDS-60ca 7.5V, PDS-60 12V and PDS-60ca 24V are
compact, robust power/data supplies for indoor and outdoor installa-
tions. The PDS-60ca 7.5V, PDS-60ca 12V, and PDS-60ca 24V provide
power and data to Color Kinetics Chromasic™ driven product lines,
and are available with DMX, Ethernet, and preprogrammed control
options.
This guide contains important information on installing and using your
new PDS-60ca. Please read it carefully and save it for future refer-
ence.
Included In This Box
•
Power/data supply with cover, gasket attaching screws,
and NPT
threaded seal plugs
• 2 Spare fuses (Only with PDS-60ca 7.5V and PDS-60ca 12V)
• Installation Guide
Additional Items Needed
•
Mounting hardware and tools
• Standard strain relief cable clamps (Indoor applications)
• Water-tight conduit and fittings (As required per local codes)
• Electronic grade RTV Silicone (UL recognized) to seal conduit
connections as required
• 5/16" hex wrench or adjustable wrench for seal plugs
• Wire nuts
Scope of This User Guide
The goal of this user guide is to explain in an easily understandable
language the necessary steps to install the PDS-60ca with preprogrammed
control and assure peak performance. Its intended use is for reference
only, by persons who are fully qualified. This document should never be
considered a substitute for any provisions of a regulation or state and/or
local code.
Identification and Warnings of Safety Hazards
In accordance with ANSI Z535.4 the following system of identifying
the severity of the hazards associated with the products is used:
“
DANGER
” Imminently hazardous situation which, if not avoided, will
result in death or serious injury.
“
WARNING
” Potentially hazardous situation that, if not avoided, could
result in death or serious injury.
“
CAUTION
” Potentially hazardous situation that, if not avoided, may
result in minor or moderate injury or property damage.
DANGER
: Ensure that main power supply is off before installing, wir-
ing, or servicing the PDS-60ca power supply. Failure to adhere to
these instructions will result in death or serious injury.
WARNING
: The PDS-60ca power supply must be installed by
a qualified professional in accordance with NEC and relevant
local codes. Failure to comply can result in death, serious injury, or
property damage.
WARNING
: Do not attempt to install or use the PDS-60ca until you read
and understand the installation instructions and safety labels. Failure
to adhere to these instructions could result in serious injury or property
damage.
WARNING
: Do not use the PDS-60ca if power cables are damaged.
Doing so can result in death, serious injury, and property damage.
WARNING
: This is a class A product. In a domestic environment this
product may cause radio interference in which case the user may be
required to take adequate measures.
CAUTION
:
Ensure that the PDS-60ca is securely attached, properly
mounted, and free of excessive vibration. Failure to do so will result in
property damage and void the warranty.
CAUTION
:
When sealing the PDS-60ca, ensure that the gasket is
seated properly, that no wires are pinched, and that the housing is
free of foreign material and debris. Failure to do so will cause seal
failure resulting in property damage and voiding the warranty.
CAUTION
: Do not hot swap. Ensure the power supply is off before con-
necting or disconnecting fixtures. Hot swapping will result in property
damage and void the warranty.
CAUTION
: Do not modify or alter the PDS-60ca. Doing so will void the
warranty.
CAUTION
:
For outdoor installations, seal on points of entry and exit
with electronic grade RTV Silicone. Failure to do so will result in prop-
erty damage and void the warranty.
NOTE
:
The instructions and precautions set forth in this user guide are
not necessarily all inclusive, all conceivable, or relevant to all applica-
tions as Color Kinetics cannot anticipate all conceivable or unique
situations.
Owner/User Responsibilities
It is the responsibility of the contractor, installer, purchaser, owner, and
user to install, maintain, and operate the PDS-60ca in such a manner
as to comply with all state and local laws, ordinances, regulations,
and the American National Standard Institute Safety Code.
INSTALLING THE PDS-60ca
The PDS-60ca shall be installed by a qualified electrician in accor-
dance with NEC and relevant local codes for power supplies. A
power screwdriver is recommended for mounting the unit.
Mounting the Housing
•
Select the location to mount the housing, keeping the PDS-60ca
within the maximum distance specified for your fixture. Refer to your
fixture user guide for the cable run information.
•
Using the seal plugs and gaskets provided, seal all conduit holes
not needed for the installation. Tighten plugs until gaskets are
slightly compressed. Do not over tighten
.
• Mount the housing to a flat surface using four screws suitable for the
mounting surface. Mounting slots are located on the flanges at each
end of the housing. (See mounting details, Fig. 1.)
WIRING THE PDS-60ca
After mounting the power/data module, you are ready to connect
power, lights, and data to the PDS-60ca.
Connecting Power to the PDS-60ca
Indoor Installation
• Insert power cable into the power connection chamber of the PDS-
60ca.
• Using pig tails and wire nuts, connect Line (black), Neutral (white),
and Ground (green/yellow). Follow local electrical codes for
internal wire bending.
• Use a standard strain relief to hold the cable. See Fig. 2
Outdoor Installation
•
Pull power cable through outdoor rated conduit and into the
power connection chamber of the PDS-60ca. Use RTV Silicone
on the conduit coupler and ensure that conduit connection to the
PDS-60ca is water-tight.
• Using wire nuts, connect Line (black), Neutral (white), and Ground
(green/yellow). Follow local electrical codes for internal wire
bending. See Fig. 3.
NOTE
:
It is the end user’s responsibility to use the proper conduc-
tors to permanently connect the incoming facility power, and to
provide means for disconnecting the system.
Connecting Lights to the PDS-60ca
• Insert the fixture leader cable into the power out/data connection
chamber of the PDS-60ca.
NOTE
: Outdoor rated lights have water-tight couplers on the cables.
Ensure that the water-tight coupling is properly installed and sealed
with RTV Silicone to ensure NEMA 4 protection. Refer to the user
guide for your lights for instructions. These couplers also provide
strain relief. See. Fig. 4
• Plug connector into a power output receptacle. Power outputs are
labeled Out 1 and Out 2. See Fig. 4
• For indoor rated lights, use a standard screw connector strain relief
to hold the cable. See Fig. 4
• Refer to the user guide for your lights to determine maximum
number of lights per power/data supply and specific wiring
requirements.
PDS-60ca 7.5V
PDS-60ca 12V
PDS-60ca 24V
INSTALLATION GUIDE
Color Kinetics Incorporated
10 Milk Street, Suite 1100
Boston, MA 02108
Tel 888 Full RGB
Tel 617 423 9999
Fax 617 423 9998
[email protected]
www.colorkinetics.com
ITEM# 109-000015-00 (7.5V)
109-000016-00 (24V)
109-000020-00 (12V)
This product is protected by one or more of the following patents: U.S. Patent Nos.
6,016,038, 6,150,774 and other patents listed at http://colorkinetics.com/patents/.
Other patents pending.
©2003-
2005 Color Kinetics Incorporated. All rights reserved. Chromacore, Chromasic,
Color Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, ColorCast,
ColorPlay, ColorScape, Direct Light, iColor, iColor Cove, iPlayer, Optibin, QuickPlay,
Sauce, the Sauce logo, and Smartjuice are registered trademarks and DIMand,
IntelliWhite, Powercore, and Video With Light are trademarks of Color Kinetics
Incorporated.
PUB-000099-01 Rev 05
PREPROGRAMMED CONTROL
OUT
1
DMX/ETHERNET
IN
OUT
2
DMX
OUT
8.3"
(21 cm)
1"
(2.5)
0.8"
(2 cm)
Power Out/
Data
Connection
Mounting Slots
2"
(5 cm)
Mounting Slots
Fig. 1
100-240VAC
Line - Black
Neutral - White
Ground - Green/Yellow
Strain Relief
Ground from external
power source. Ground from
internal
power supply
• Use a standard strain relief to hold the cable. See Fig. 2
Fig. 2
100-240VAC
Line - Black
Neutral - White
Ground - Green
Conduit with
water-tight
fitting
Fig. 3
OUT 1
OUT
2
Leader
Cable
Strain
Relief
OUT 1
OUT
2
Locknut with
Internal Gland
Grommet
Assembled Coupler
Seal with RTV
Silicone.
INDOOR
OUTDOOR
O-Ring
Fig. 4
CAUTION
:
PDS-60ca must be installed in a location that allows air to
move freely. Packing insulation around the housing or mounting in a
sealed location that raises ambient temperature above 104º F (40º C)
will result in property damage and void the warranty.
CAUTION
:
Ensure proper installation for outdoor applications to main-
tain NEMA 4 ratings. Failure to do so will result in property damage
and void the warranty.
DANGER
:
Turn off main power supply before wiring the PDS-60ca.
Failure to do so will result in death or serious injury.
Setting Preprogrammed Effects
•
Light Type
: Using the toggle switch, select the type of lights that
are attached to the PDS-60ca. See Fig. 5.
POSITION
1
for iColor Flex SL, iColor Flex SLX, iColor Cove EC,
iColor Cove QL or Pro products.
POSITION
2
for iColor Tile FX.
POSITION
3
for future products.
NOTE
:
Before engaging power, set the light type using the toggle
switch. If Light Type is changed after power is engaged, the power
supply must be recycled in order to recognize the change.
•
Mode
: After selecting the light type, use the Mode button to select
the effect. Press and release the Mode button to cycle through each
effect. The following effects are available for each light type.
FLEX SL, COVE EC, PRO
: Rainbow, Random, Color Wash, Fixed Color.
TILE FX
: Burst, Spiral, Vertical Rainbow, Horizontal Rainbow, Random,
Color Wash, Fixed Color.
•
Speed
: Press and release to cycle through four speeds.
NOTE
:
When in Fixed Color mode, press and hold the Speed button
to change colors.
• Option
: The Options button lets you modify certain effects as
follows:
RANDOM
: Toggles between snap and fade changes.
RAINBOW
: Each cycle increases through four width settings then
reverses direction and decreases widths.
COLOR WASH
,
BURST
, and
SPIRAL
: Reverses direction.
NOTE
: Once mode, speed, and options are set,
PDS-60ca remem-
bers your settings and recalls them after each power cycle.
Sealing the Power Supply
•
After all the power and data connections have been made, and all
through holes are water-tight, replace the cover and attach with pro-
vided screws. Tighten screws to 8 to 10 in/lbs.
NOTE
: Before attaching cover, ensure gasket is seated properly and
that no wires are pinched.
Replacing Fuses
Each power output terminal of the PDS-60ca 7.5V and PDS-60ca 12V
is equipped with a fuse. Red LEDs are located next to each fuse to
indicate that power is present that the output connector. If an output
terminal is not functioning, replace the fuse as follows:
• Turn off power.
• Remove the fuse from the malfunctioning fuse terminal.
• Insert the replacement fuse into the fuse terminal. Use only correct
fuse size as noted on the fixture. See Fig. 6.
PDS-60ca SPECIFICATIONS
Power Output
7.5VDC, 12VDC or 24VDC, 62W
Power Input
100-240VAC (auto ranging), 50-60 Hz; 1.7A
Ambient Temp
14˚F to 104˚F (-10˚C to 40˚C)
Packaging
NEMA 4 enclosure
Dimensions
8.27” (31 cm) X 5.36 ” (14 cm) X 3.57” (9 cm)
Connectors
RJ45 data input and output connectors; 4-pin power
output connectors
Data Interface
Color Kinetics Chromasic data interface output
WARRANTY
This product is sold pursuant to CK’s Standard Terms and
Conditions (the “T&Cs”) which may be found at
http://colorkinetics.com/howtobuy/buy/terms and which contain
important provisions, including, among others, Limited Warranty,
exclusions and limitations on CK’s liability for damages, and restric-
tions on the remedies that are available to you.
1 - FLEX SL, FLEX SLX,
COVE EC, COVE QL, PRO
2 - TILE FX
3 - FUTURE PRODUCTS
OPTIONS
SPEED
MODE
OUT
1
DMX/ETHERNET
IN
OUT
2
DMX
OUT
Fig. 5
OUT
1
DMX/ETHERNET
IN
OUT
2
DMX
OUT
Fuse
PDS-60ca 7.5V
PDS-60ca 12V
Fig. 6
WARNING
: Ensure that the power supply is off before connecting or
disconnecting fuses.

This manual suits for next models

3

Other COLORKINETICS Controllers manuals

COLORKINETICS iPlayer 3 User manual

COLORKINETICS

COLORKINETICS iPlayer 3 User manual

COLORKINETICS Data Enabler Pro User manual

COLORKINETICS

COLORKINETICS Data Enabler Pro User manual

COLORKINETICS iColor Player User manual

COLORKINETICS

COLORKINETICS iColor Player User manual

COLORKINETICS VAYA Series User manual

COLORKINETICS

COLORKINETICS VAYA Series User manual

COLORKINETICS ColorDial Pro User manual

COLORKINETICS

COLORKINETICS ColorDial Pro User manual

COLORKINETICS AuxBox User manual

COLORKINETICS

COLORKINETICS AuxBox User manual

COLORKINETICS Data Enabler IntelliPower User manual

COLORKINETICS

COLORKINETICS Data Enabler IntelliPower User manual

COLORKINETICS iColor Player User manual

COLORKINETICS

COLORKINETICS iColor Player User manual

COLORKINETICS Light System Manager gen5 User manual

COLORKINETICS

COLORKINETICS Light System Manager gen5 User manual

COLORKINETICS Gen6 User manual

COLORKINETICS

COLORKINETICS Gen6 User manual

Popular Controllers manuals by other brands

AutoGate GENESIS Retrofit Instructions

AutoGate

AutoGate GENESIS Retrofit Instructions

BN Thermic RT26 instructions

BN Thermic

BN Thermic RT26 instructions

Neptronic SPC Specification and installation instructions

Neptronic

Neptronic SPC Specification and installation instructions

Honeywell RA116A user manual

Honeywell

Honeywell RA116A user manual

ITT Advantage Actuator 2.0 Maintenance manual

ITT

ITT Advantage Actuator 2.0 Maintenance manual

Velleman VM192RF user manual

Velleman

Velleman VM192RF user manual

esportsim Formula Steering Wheel 2 Series user manual

esportsim

esportsim Formula Steering Wheel 2 Series user manual

Remote Control Technology Muirhead 11337 product manual

Remote Control Technology

Remote Control Technology Muirhead 11337 product manual

Redline Communications RDL-3000 Series installation guide

Redline Communications

Redline Communications RDL-3000 Series installation guide

Honeywell SEC-H-602 manual

Honeywell

Honeywell SEC-H-602 manual

rotai RT-7900S Repair manual

rotai

rotai RT-7900S Repair manual

Honeywell Ex-Or MLSM2000A Installation and commissioning instructions

Honeywell

Honeywell Ex-Or MLSM2000A Installation and commissioning instructions

EOS ECON D3 Installation and operating instruction

EOS

EOS ECON D3 Installation and operating instruction

Kimray GEN 3 Installation operation & maintenance data

Kimray

Kimray GEN 3 Installation operation & maintenance data

Bodet Scorepad user manual

Bodet

Bodet Scorepad user manual

Artecta Domotion DLC-4 RGBW instruction manual

Artecta

Artecta Domotion DLC-4 RGBW instruction manual

dbx PMC16 owner's manual

dbx

dbx PMC16 owner's manual

MH EDS O2D2 instruction manual

MH

MH EDS O2D2 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.