Tripla 65
On Completion of Work
Having finished the job and before any type of maintenance is done, proceed as follows:
1. Close the cock (1)
2. Push the brushes base switch (2) into the UP position, until
the maximum UP position is reached.
3. position the switch of swueegee up/down (1) into the central position, so
that the suction motor keeps on working to empty the suction hose for about
20 seconds, then put it up into the U
20 seconds, then put it up into the UP position.
4. Bring the machine up to the place provided for the water outlet.
5. Turn the general key switch (2) 1/4 round counter clockwise
6. Take off the exhaust pipe from its hook, unscrew the exhaust plug and
empty the recovery tank. To simplify draining operation, it is recommended to hold
with one hand the hose upwards more than the water level inside the tank is and with
the other hand unscrew the knob and take off the plug. Slowly lower the hose and the
liquid will start to drain at the desired speed.
liquid will start to drain at the desired speed.
Daily Maintenance
Recovery Tank Cleaning
1. Empty the tank through the fexible hose, unscrewing of some
turns the knob and then taking off the exhaust plug.
Attention: This operation ahs to be carried out using
gloves to protect contact wiht dangerous solutions.
2. Open the side plug by unscrewing the knob and rotating the
closing blade.
3. Rinse the tank and clean the exhaust plug
4. Check the perfect position of the side plug gasket
5. Retighten the side plug and the plug onto the exhaust pipe
Cleaning of the Squeegee
Clean the squeegee with a water jet. Check the rubber wear and if neccessary, turn them up-side or change them. The
careful cleaning of the complete suction group assures higher life of the suction motor.
Replacement of the Squeegee Rubber
If the squeegee is worn and does not dry well, it is possible to change the drying edge.
Proceedngs as follows:
1. Push and rotate the fixing plates
2. Slip off the rubber blade and rubber itself
3. Turn the rubber up-side down and if neccessary, replace it
4. Adjust the squeegee height
5. Reassemble everything repeating inversley the above operations.
5. Reassemble everything repeating inversley the above operations.
Solution Tank and Filter Cleaning
When the solution tank is empty:
1. Open the cock
2. Unscrew the filter and rinse it thoroughly
Industrial Floorcare Machines | Issue 1 | 1st May 2012
7. The squeegee has to be lifted when the machine is not operating. In this way damage
to the squeegee rubbers is avoided.
8. Take off the brushes and clean them with a water jet.
9. Remove the hopper unit (if washing/sweeping unit is being used) to empty debris,
then clean out carefully.
Attention: This operation has to carried out using gloves to protect
from contact with dangerous solutions.