Comedes Lavaero 1000 User manual

air purifier
Lavaero 1000

table of contents
foreword................................................................................................
safety instructions ...............................................................................
Intended Use.............................................................
Technical data .....................................................................................
device description ...........................................................................
Before commissioning.............................................................................
commissioning .......................................................................................
Front cover handling........................................................
filter change ..............................................................................
air humidification
Cleaning the device..............................................................................
Malfunctions and
remedies..........................................................................
Further information...........................................................................

Dear customer,
Thank you for choosing the Lavaero 1000 from Comedes GmbH.
You have purchased a powerful air purifier designed to the latest technical standards. To
ensure that the device will remain your faithful servant over a long period of time, we ask you
to study the operating instructions, in particular the safety instructions, in detail.
If you still have questions about the device after you have read the operating instructions,
please do not hesitate to contact us:
E-mail address: service@comedes.com
If you enter your telephone number, we will call you back free of charge.
We welcome any feedback from our customers and would appreciate it if you contact us.
Yours sincerely
Philipp Thannhuber
Managing Director
Comedes GmbH
Warning:

Read the instructions carefully before commissioning. Failure to follow the safety instructions
and instructions may result in electric shock, fire and/or serious injury. Keep all safety
instructions and instructions for the future.
Watch your step! Do not open the device until the mains plug has been disconnected from
the mains socket. Risk of death due to electric shock! Have repairs carried out only by an
authorised specialist workshop.
safety instructions
Check the voltage of 220-240V before use.
Check the mains plug before plugging in.
Do not place the unit in direct sunlight, directly in front of the air outlet of
air conditioners or near heat sources. This can cause plastic parts of the
device to deform, discolour or malfunction.
Do not operate the air purifier near televisions or radios. This may cause
image noise, noise and other disturbances. Ensure a minimum distance
of 1 meter between the air purifier and these devices. Do not use the
same socket for these appliances and the air purifier.
The unit should only be operated standing on the floor.
To avoid tipping over or falling to the ground, the air purifier should not be placed on an
uneven, sloping or moving surface during operation.
In order to ensure good air circulation and effective air cleaning, ensure
sufficient distance from walls and furnishings. The distance to the top,
sides and back should not be less than 30cm. A minimum distance of
30cm from the front of the unit should be maintained.
Do not place any objects on the unit and never cover the
air inlet or outlet. Make sure that no moving objects, such
as curtains, can block the air inlet or outlet. This can
damage/destroy the blower motor.
Always switch and disconnect the device before moving or lifting it. Do not pull the
power cord when moving or storing the unit. This can lead to electric shock and fire
hazard.
Take care not to damage the power cord, plug or socket. The mains
cable must not be shortened, strongly twisted or bent. Do not pull the
power cord to disconnect or move the unit. If the supply cable is
damaged, stop operation and have it replaced immediately by the
manufacturer or an authorised specialist workshop.
Do not touch the power plug or the product with wet hands as this
may result in electric shock.

Do not insert any objects (especially metallic objects) or your fingers
into the air inlets and outlets of the device. This could result in electric
shock and injury.
Never use hairsprays, thinners or flammable gases in the vicinity of the device, as there
is a risk of fire and explosion.
Make sure that no liquids such as water and cleaning agents get into the
device and never immerse it in water.
The air purifier is not suitable as a replacement for fans, ventilation
systems, vacuum cleaners or extraction hoods.
Never operate the appliance near heat sources such as heaters, open fires,
stoves, or gas and petrol powered appliances.
Do not operate the appliance in very humid or hot environments, such as
bathrooms, toilets or kitchens.
Make sure that the remote control is kept out of the reach of children.
Do not grip the unit by the two air inlets to carry it.
Use the two recessed grips on the sides for this purpose.
Never turn the unit upside down because of the humidification unit inside.
Do not operate the air purifier at the following locations:
◦ Unstable places: This may cause the unit to tip over or fall, resulting in personal
injury, electric shock or fire.
◦ Hot or humid rooms, such as showers. This may result in electric shock or fire.
◦ Places such as kitchens where steam or smoke is emitted.
Do not use the air purifier in rooms where smoke-based insect killers are used.
◦ Chemical residues can accumulate in the device and then be released, which can
lead to damage to health.
◦ After the use of such insect killers or mosquito spirals, the room should be fully
ventilated before using the air purifier.
Further safety-relevant information

If any of the following occur, immediately disconnect and disconnect the air purifier and
contact the manufacturer.
◦ The device makes unusual noises or vibrates strongly during operation.
◦ The equipment, power plug or cord may become abnormally hot.
◦ The smell of fire or smoke is perceptible.
◦ One of the keys can no longer be operated.
◦ Other irregularities or malfunctions.
Clean the mains plug regularly. If it is heavily soiled or very damp/wet, this can pose a
fire hazard.
◦ Disconnect the device and clean the plug with a dry cloth.
◦ If the device will not be used for a longer period of time, disconnect it.
Always disconnect the unit before moving, cleaning or cleaning/replacing the filter.
Make sure that the plug is always firmly and securely plugged into the socket.
Do not use the device if the mains plug or socket is damaged.
Always reach for the mains plug to disconnect the device. Do not disconnect the unit by
pulling the power cord.
Use the ON/OFF switch to turn the unit on and off.
Never use the plug to switch the unit "on and off".
If candles or gas ovens burn in the same room during operation, open the window
occasionally.
The device must not be used in an environment containing high levels of dust or
chlorine.
The device must not be used in closed and narrow rooms.
If the supply cable is damaged, stop operation and have it replaced immediately by the
manufacturer or an authorised specialist workshop.
The device may only be operated by persons who are physically and mentally capable
of correct operation according to these operating instructions or who have been
instructed on this device by a responsible person.
Do not allow children to play with the device or its packaging, such as plastic films.
Do not operate the unit without a filter, as dust cannot be filtered and can get inside the
unit. This can lead to malfunctions.
Intended Use
The air purifier is only intended for air cleaning of privately used rooms (e.g. living rooms,
bedrooms, storage rooms or cellars). The user must comply with the specified operating
parameters of these instructions.
The machine may only be used for its intended purpose. Any further use beyond this is not
intended. The user/operator and not the manufacturer shall be liable for any damage or injury
of any kind resulting therefrom.
Air cleaners are only conditionally suitable for use in kitchens, as oils and fats in the air as well
as increased soot pollution can very quickly clog the filters.

Technical data
Product name: Comedes Lavaero 1000
Tension: 220-240V / 50/60 Hz
Nominal power: 85W
Air flow rate: 488m³/h
Timer (hours): 1-12
Weight: 11,3 kg
Dimensions (W*H*T): 401*662*232 mm
Noise emission: max 69dB(A)
device description
air inlet
(on both
sides)
front cover
control panel
display
air outlet
recessed
water tank

Control panel/display
remote control
A button cell Lithium Cell CR2032, 3V is required for the remote control.
(Not included in delivery.)
Before commissioning
Remove the filter elements from the unit, remove the protective films and reinsert them into
the unit. Follow the steps in the chapter "Filter change". The filters should normally be changed
every 6-9 months.
commissioning
Inserting the device
When you plug in the device, the power LED lights up.
Caution: Never insert or remove the device with wet hands.
ion
sleep
timer
power
Speed +
AUTO
Filter Reset
UV Light
/Sterilize
Speed
unlock
lure
control panel
display

POWER
The power switch is used to turn the unit on and off.
(The symbol lights up red in standby mode and orange when switched on).
The device always starts in automatic mode.
AUTO
Press the "AUTO" button to start the automatic mode. In this mode, the fan level is
automatically selected depending on the air quality. If the mode is active, the
"AUTO" button lights up. The ionizer and the UV light are switched on in this mode.
By pressing the "IONIZER"- or "IONIZER" button
"STERILIZE" button on the remote control, the ionizer or the UV light can be
but be switched off.
To switch from automatic mode to manual mode, press one of the following keys.
of the two "SPEED" buttons.
Relationship between PM2.5 measured value, fan stage and color indicator
fan stage
PM2.5
Measured
value
colour
indicator fan stage
PM2.5
Measured
value
colour
indicator
1 0-50 green 5 121-140 Yellow
2 51-80 6 141-160
3 81-100 Blue 7 161-300 red
4 101-120 8 301-500
timer
With the timer you can set the running time of the device. Times between 1 and 12
hours can be selected. If the display shows 12 and you press the button again, the
timer is switched off.
When the time has elapsed, the unit switches off automatically.
If the timer is active, the corresponding button lights up and the display shows the
remaining runtime is displayed.
Ionizer (IONIZER)
This button on the remote control switches the ionizer on and off.
The unit always starts with the ionizer switched on.
If the ionizer is switched on, the corresponding indicator on the display lights up.
UV light (STERILIZE)
This button on the remote control switches the UV light on and off.
The unit always starts with the UV light switched on.
If the ionizer is switched on, the corresponding indicator on the display lights up.
sleep
In this mode, the device operates at the lowest fan speed for minimal noise.
Except for the Sleep display, all displays go out.
If a running time has been set via the timer before the start of the sleep function,
this setting remains and the device switches itself off after the time has elapsed.
To exit Sleep mode, press either Sleep, Auto or one of the two Speed buttons
twice in succession.
light sensor
The air purifier is equipped with a modern light sensor. If the unit works in
automatic mode, both the air quality and the light intensity are monitored. If it is

dark in the room for longer than 2 minutes, the device automatically switches to
sleep mode. If the room is illuminated for longer than 3 minutes, the unit returns
to normal automatic mode.
speed
Press the "+" key to increase the fan speed.
Press the "-" key to lower the fan speed.
The set fan level (1-8) is shown on the display.
Child lock (Lock)
Press the "CHILD LOCK" button to activate the child lock/key lock. If the
parental control is activated, the corresponding key lights up.
Press and hold this button again for at least 5 seconds to release the key lock.
The child lock is activated by pressing the "LOCK" button on the remote control
and deactivated by simply pressing the "UNLOCK" button.
Filter change indicator and filter reset
The Comedes Lavaero 1000 has a modern filter change indicator.
After 320 hours, the filter change symbol starts flashing. This is to inform you
that the prefilter and the HEPA element should be cleaned. After cleaning and
reinserting the filters, press and hold the "Reset" button for at least 5 seconds to
reset the filter timer.
After 1500 hours, the filter change symbol lights up continuously. This will
indicate to you that the two main filters should be replaced. After changing the
filters, press and hold the "Reset" button for at least 5 seconds to reset the filter
timer.
Depending on the type and intensity of use, the filter may have to be replaced
before the filter change indicator lights up. Therefore, check the filter regularly.
Front cover handling
The air purifier can only be operated with the front cover inserted correctly.
For a firm hold, the front cover is locked on both sides with magnets in the upper area.
1. Removing the front cover

2. Installing the Front Cover
filter change
After some time in operation, the filter elements must be replaced.
1. filter removal
Always switch and disconnect the device for this purpose.
Release the latches in
the upper part of the
front cover by pulling
lightly.
The front cover can
now be removed
diagonally upwards.
First place the
front cover on top.
Now close the front
cover by pressing it
down.
To lock the front cover,
press it into the locks with
both thumbs.

Take the Remove the Remove the filters
Remove the filter cover. Prefilter. always first from
the
Protective film, before
you
and they use it.
2. The prefilter can be cleaned under running water and does not need to be replaced.
3. Now check the filters. If the HEPA element is not yet too discoloured, vacuum it off with
a vacuum cleaner (preferably outdoors).
4. If the filters are very dirty or discoloured, replace them.
5. Please note that the replacement filters must be removed from the protective film
before they can be inserted into the device.
6. Inserting the filters
First the HEPA filter element must be used. Make sure
that the filter is inserted with the tab facing outwards.
Secondly, the activated carbon/cold catalysis
combination filter must be used. Make sure that the
filter is inserted with the tab facing outwards.
Thirdly, the prefilter must be used. Make sure that the
filter is inserted so that the side with the handle is
facing outwards.

Finally, replace the filter cover.
Attention: The unit can only be started if the filter cover is inserted
correctly.
air humidification
The Comedes Lavaero 1000 is equipped with an air humidification function. Humidification
takes place by means of the evaporation principle. As soon as the water tank is filled with
water, the air flowing through the unit is automatically moistened. The higher the fan speed,
the higher the humidification performance.
If the water tank is empty, the corresponding display flashes on the display. The unit continues
to operate normally, which means it can be operated without humidification. If the water tank
is removed, the appliance switches off and the symbol on the display lights up continuously.
Filling the water tank:

Always switch and disconnect the device for this purpose.
Cleaning the device
Disconnect the mains plug before cleaning!
• Clean housing:
• Do not use aggressive cleaning agents, but only a dry and soft cloth.
• Clean the prefilter (every other week):
1) Pull the
water tank out
of the side of
the appliance.
2) Remove the
humidifying filter from
the protective film.
3) Insert the
humidifying filter
into the water
tank.
4) Open the
rubber cover of
the filling opening.
5) Fill the water
tank via the filling
opening with
approx. 1 litre of
cold, clear water.
6) Close the filling
opening again with
the rubber cap.
7) Push the water
tank back into the
side of the unit.

• Remove the prefilter from the unit as described in the chapter "Changing
the filter".
• The prefilter can be vacuumed or washed under cold, clear water. Dry the
filter before reinserting it into the unit.
• Clean the activated carbon/cold catalysis filter combination (every other
month):
• Remove the filter from the unit as described in the chapter "Changing the
filter".
• Carefully clean the front of the filter with a vacuum cleaner.
• Place the filter in a well-ventilated place so that some of the bound gases
can escape.
• Do not place the filter in direct sunlight.
• When cleaning the filter, be careful not to damage it.
• Never use water to clean this filter.
• Clean HEPA element (every other month):
• Remove the filter from the unit as described in the chapter "Changing the
filter".
• Carefully clean the filter with a vacuum cleaner.
• Place the filter in a well-ventilated place so that some of the bound gases
can escape.
• Do not place the filter in direct sunlight.
• When cleaning the filter, be careful not to damage it.
• Never use water to clean this filter.
• Clean the air outlet:
• Switch on and disconnect the device.
• Open the cover of the air outlet by pressing
on the cover and pulling it upwards.
• You can now carefully clean the air outlet with
a dry cloth.
• Then close the cover of the air outlet.
• If the cover of the air outlet is opened, the
unit switches off automatically. The unit cannot be restarted until the lid has
been inserted correctly.
• Clean air quality sensor (every second month):
• The air quality sensor of the air purifier should be cleaned at least every 2
months to ensure accurate measurement.
• Make sure that the device is switched off and disconnected.
cotton buds

• First, remove the air quality sensor cover and clean it with a soft brush or
cloth.
• Now carefully clean the lens of the air quality sensor with a cotton swab.
• In poor lighting conditions, use a flashlight or similar to see the lens well.
• Just clean the lens. Do not insert the cotton swab into any other opening in
the sensor unit.
• Finally, replace the cover of the air quality sensor.
Malfunctions and remedies
Current operating instructions can be found at http://www.comedes.com
Turn off the unit immediately and contact your dealer if any of the following problems occur:
• Fuse's blown.
• Foreign material gets into the device.
• The plug or power cord heats up.
Do not open the unit without authorized service personnel. However, you can check the
following causes of faults yourself:

The device cannot be switched on:
• Is the plug inserted correctly?
• Has the fuse blown or is there no voltage at the socket?
• Isn't the device upright or has it been put down?
• Is the child lock activated?
• Is the filter cover fitted correctly?
The air flow at the outlet opening is lower:
• Is the filter too dirty or clogged?
The air quality is always very good, even though the air is polluted:
• Has the unit been positioned in a narrow niche or similar?
• Can sufficient air circulation build up in the room?
Poor air quality is always displayed even though the unit has been running for a long
time:
• Is the particle sensor dirty?
The air purifier emits an unusual odor:
• Are the filters too dirty or clogged?
• Has the filter not been replaced for a long time?
The air purifier does not automatically switch to sleep mode:
• Is automatic mode activated?
The device is disproportionately loud:
• Does the device stand on an uneven surface?
• Isn't the filter unpacked?
• Is the filter too dirty or clogged?
During operation, a beating or chirping noise can be heard:
• Is the ionizer very dirty?
Remote control does not work:
• Replace the battery.
The filter performance is very low:
Are the filters inserted in the correct order?
• Aren't the filters unpacked?
• Do the filters have to be replaced?
Further information
Filter system:
prefilter
The prefilter is the first barrier for particles. Large particles in the room air are collected by this
filter and can later either be vacuumed off with a vacuum cleaner or washed off under running
water.
cold catalysis filter
The catalytic effect of this filter is also used in normal living environments. Activation by UV
light, high temperatures or pressure is not necessary.
Through the catalytic reaction can reduce the concentration of various gaseous compounds,
such as formaldehyde, benzene and TVOC. The reaction of these gases produces water and
carbon dioxide.
activated charcoal filter

Activated carbon, thanks to its highly porous structure, has a very large surface area, which
enables it to adsorb a large amount of different odorants and flavors, as well as various VOCs.
HEPA Filter
The HEPA (High Efficiency Particulate Airfilter) medium is able to remove even the smallest
particles from the room air. The filtration is carried out by means of mechanical filtration and
particle filtration by adhesion forces.
The HEPA element is additionally equipped with an antibacterial filter fabric.
ionizer
In the last step, the air finally flowing out of the device is mixed with a small quantity of
negatively charged ions. These ions attach themselves to the smallest particles in the room air
and charge them statically. The particles charged in this way then tend to accumulate with
other particles and form larger clusters, which can then be more easily absorbed by the filter
medium.
ultraviolet light
Irradiation with ultraviolet light is used for disinfection in many areas of industry and medical
technology. This disinfecting and sterilizing effect is also used to clean the room air flowing
through the air purifier.
Notes on air cleaning for cigarette smoke
Cigarette smoke consists of numerous complex chemical compounds. For the air purifier, it is
essentially divided into solid components of smoke and gaseous components of smoke. The
solid smoke particles are filtered out by the HEPA filter. The gaseous components can be
absorbed by the activated carbon and cold catalysis filters.
• The device should be placed as close as possible to the smoke source.
• Depending on how many cigarettes are smoked, the service life of the filter is
shortened.
Information on air cleaning in case of problems with pollen
The air purifier is able to filter all common pollen from the air. These remain in the HEPA filter.
In order for the device to be fully effective and to significantly reduce the pollen concentration,
we recommend the creation of a refuge in which the air purifier is located. The device can only
remove airborne allergens, but not allergens that have already settled on beds, walls,
furniture, etc. The device can only remove airborne allergens.
For this reason, please observe the following instructions:
• Carry out a basic cleaning of the room before using the device.
• Do not use dust cloths for cleaning, but a damp cloth.
• Vacuum upholstered furniture at least once a week. Use a vacuum cleaner suitable for
allergy sufferers.
• Wipe the room wet at least once a week.
• Let the unit run at levels 1-4 during the day.
• Turn off the device for sleeping.
• Set the fan to level 5-8 during ventilation. The best time to air the rooms is between
6:00 and 8:00 in the morning in cities or from 19:00 in rural areas.
Information on air cleaning in case of problems with house dust
House dust is usually generated by mites living in upholstered furniture, pillows, blankets and

mattresses. The house dust remains there for the time being. The air purifier can only remove
house dust from the air. It is therefore advisable to turn off sources of house dust before using
an air purifier.
• Cover mattresses allergen-proof (Encasing).
• Cover pillow and duvet allergen-tight.
• Wash pillows and duvets frequently.
• Replace older mattresses.
• Use vacuum cleaner with fine filter.
• Vacuum mattresses monthly.
• Avoid dust traps in the bedroom.
• Do not place indoor plants in the bedroom.
This product must not be disposed of with household waste. This air purifier
must be disposed of at a recycling point for electronic and electrical equipment.
You can obtain further information about the relevant acceptance points from your
local authority or city administration, or from Comedes GmbH.
Other manuals for Lavaero 1000
1
This manual suits for next models
1
Table of contents
Other Comedes Air Cleaner manuals

Comedes
Comedes Lavaero 240 User manual

Comedes
Comedes Lavaero 280 User manual

Comedes
Comedes Lavaero 100 User manual

Comedes
Comedes Lavaero 1000 User manual

Comedes
Comedes Lavaero 1200 User manual

Comedes
Comedes Lavaero 1200 User manual

Comedes
Comedes LR 50 User manual

Comedes
Comedes Lavaero 900 User manual

Comedes
Comedes Lavaero 280 User manual

Comedes
Comedes LR 700 User manual