Comedes LR 700 User manual

Air purifier
LR 700

Table of Contents
Foreword................................................................................................................... 3
Safety information .......................................................................................................4
Intended use ............................................................................................................. 5
Technical data ............................................................................................................ 6
Layout ....................................................................................................................6-7
Before startin up....................................................................................................... 8
Startin up ............................................................................................................. 8-9
Chan in the filter .................................................................................................10-11
Cleanin the device .................................................................................................. 12
Faults and troubleshootin ......................................................................................... 12
Tips on purifyin the air in cases of ci arette smoke
and problems with pollen or household dust ................................................................. 13
EC declaration of conformity ...................................................................................... 14

Dear Customer,
Thank you, that you have chosen the Comedes LR 700 air purifier, which has been
manufactured accordin to the newest technolo y available.
The air purifier LR 700 is equipped with a multilevel filter system, which has been developed
accordin to the newest technolo y available. The ionizer converts positive air-particle to
ne atives (like air is cleaned while a thunderstorm).
Dust, pollen and smoke can be abolished.
Read the manual carefully, especially the safety instructions.
If you have any queries, you are very welcome to contact us.
Our E-Mail adress: service@comedes.com
If you provide your phone number we will call you back free of char e.
We are happy with feedback and look forward to your contact.
Kind re ards
Philipp Thannhuber
Comedes GmbH

WARNING:
Be sure to read the instructions before usin for the first time. Any errors made in followin
the safety information and instructions may result in an electric shock, fire and/or serious
injury. Keep all the safety information and instructions in a safe place for future use.
Important: Make sure that the power plu is removed from the socket outlet before openin
the device. Electric shock can cause fatal injury. Have repairs carried out only by an authorized
workshop. To chan e the HEPA filter, you can easily remove the front panel yourself.
Safety Instructions
• Check the volta e of 230 V before use.
• Check the power plu before plu in it in.
• Pull the power plu out of the socket outlet whenever the device is not in use.
• Never poke any small objects in the air inlet and outlet vents on the device. This may
result in a short-circuit. Be especially careful when operatin the device within reach of
children.
• Use the SPEED/ON and OFF switch to switch the device “ON and OFF”. Do not under any
circumstances use the plu to switch the device “ON and OFF”.
• Always switch off the device and pull the plu before you start to adjust it.
• Never attempt to clean the air inlet and outlet vents with pointed objects.
• Never immerse the device in water.
• Never spray inflammable liquids into the device.
• Never use the device in a wet room (e. . bathroom). Dan er of electric shock or cur-
rent transfer.
• Never use hairspray, thinners or inflammable ases in the vicinity of the device, be-
cause they could pose a risk of fire and explosion.
• If candles are lit or as heaters are on in the same room while the device is bein used,
open the window occasionally.
• Never cover the air inlet or outlet vents. This could cause irreparable dama e to the
blower motor.
• Never use the device in the vicinity of sources of heat such as heaters, naked flames
or direct sunli ht. This may cause deformation to plastic parts.
• The device must not be used as a substitute for a fan. This will drastically reduce the
service life of the filter.
• The device must not be used in environments containin lots of dust or chlorine.
• Do not place any heavy objects on the device and keep it out of the reach of children.
• Do not use the device in enclosed and confined spaces.
• If the power lead is dama ed, stop usin the device and have the lead replaced imme-
diately.
• If the device develops a defect, switch off the power switch and pull the plu .
• To avoid interference, never use the device in the vicinity of microwaves or televisions.
• The device is allowed to be used only by persons who are physically and mentally
capable of operatin it in accordance with these operatin instructions, or by persons
who have been iven trainin on the use of the device by a responsible person.
• Never switch the device on or off with wet hands.
• Never attempt to carry out any repairs or modifications, either of an electrical or a
mechanical nature, on the device yourself.
• Do not allow children to play with any of the packa in such as sheets of plastic.
• Make sure, that there is a minimum distance of 15 cm to the nearest wall.

Intended use
The air purifier is designed only for use for purifying the air in pri ately used rooms
(e. . livin rooms, bedrooms, stora e areas or basements). The user must observe all the
operational parameters specified in this manual.
The device is allowed to be used only for its prescribed purpose. Any other use is deemed to be
a case of misuse. The user/operator and not the manufacturer will be liable for any dama- e
or injuries of any kind resultin from such misuse.

Technical data
Product name: Comedes LR 700
Volta e: 220-240V ~ 50 Hz
Power consumption: 100W
Air throu hput: 300 m³/h
Timer (hours): 1-9
Ionization: 1*
10
6 Ionen/cm³/s
Wei ht: 12,5 k
Dimensions (WxHxD): 480 x 260 x 665 mm
Room size: max. 50 m²
Noise: l < 41 dB
m< 46 dB
h < 55 dB
Layout
Fi ure 1:
Fi ure 2:
Air intlet
Dust sensor
Power line
Air outlet
Control Panel
Handle
VOC Sensor

Control Panel
Fi ure 3:
Remote Control
The remote control requires a 3 V lithium cell CR2025 button cell. (Not supplied)
Timer settin
ON/OFF
Child-proof lock display
Timer-display
UV-display
Airflow
Operatin mode
ON/OFF display
Sensor dislay
Operatin mode
UV/ION switch
Fan speed
Ion display
Timer settin
Timer ON/OFF
Child-proof lock
Sender
Operatin mode
ON/OFF
Fan speed
UV/ION switch

Before startin up
IMPORTANT: Make sure that the power plu is removed from the socket outlet
before openin the device. Electric shock can cause fatal injury. Have repairs
carried out only by an authorized workshop.
Take the filter out of the unit, take off the plastic sheetin and insert it back in the device.
The main filter should normally be chan ed every 6-9 months.
To make sure you do not for et, stick the supplied sticker on the outside of the device. This
serves as a color indicator for when to chan e the filter. When the filter is the same color as
the sticker, it is time to chan e it.
The white side of the main filter must face towards the front, then you will have inserted it
correctly.
Startin up
Plu in in the device
When you plu in the device, the Power-LED will flash. The device is now ready for use.
Power
•
Press this button to switch the unit on or off.
• When the device is switched on, the quality sensors will take approx. 2 minutes to
determine the quality of the air. After the air quality has been determined, the device
will show the DUST, VOC polution and the overall air quality.
• After switchin on the device, it will start in manual mode and small fan speed.
• If you are not intendin to use the device for an
extended period of time, we recommend that you pull the power plu .
Timer
• Use this function to select the start- or runtime for the device.
• To set the starttime, select the timer when the unit is off.
• To set the runtime, select the timer when the unit is on.
• Continuous operation is indicated when all timer LEDs are dark.
• The remainin time is also shown by the LEDs.
Speed
• The speed of the fan can be chan ed durin operation by repeatedly pressin this
button to switch between Low, Medium and Hi h.
• If the unit works in automatic Mode, the fan speed will be re ulated automatically.

Function
• This Switch is for switchin the UV li ht and the ionizer on and off.
You can switch the UV and the Ion on/off in manual-, sleep- and automatic mode.
In super mode, both functions are automatically on.
UV-light
• The UV li ht provides a natural de erminatin effect in the device.
• The TIO filter after the HEPA & activated carbon filter is activated by the UV li ht. This
filter will not work without the UV li ht. The TIO filter uses the principle of
photocatalytic effects to reduce numerous odor-buildin inor anic compounds.
ab ebaut.
ANION
• Only use this function if the air in the room has already been purified for a while (after
approx. one hour when used for the first time or after heavy air contamination).
• The ions which are released form what are known as ion clusters in the air. As a result,
even the smallest of dust particles accumulate to ether and can be absorbed by the air
purifier.
• If the humidity level in the room is hi h, the walls will become dirty very quickly if the
ionizer is switched on, so it should not be switched on if this is the case.
Operating Modes
The air purifier has diverse operatin modes, which can be adjusted with the mode button.
MANUAL
If the unit is in MANUAL mode, the fan speed, UV- and Ion-function could be adjusted.
AUTO
If the unit is in AUTO mode, the fan speed, UV- and Ion-function is adjusted automatically,
accordin to the air quality.
SUPER
If the unit is in SUPER mode, the unit works in the hi hest fan speed and UV/Ion on.
SLEEP
If the unit is in SLEEP mode, the unit works in the lowest fan speed, for minimal noise
emission. Also all LEDs, expect the SLEEP LED, will be dark.
To leave the SLEEP mode, press any button.
Child-proof lock
The child-proof lock could only be activated/deactivated with the button on the remote control.
If the child-proof lock is activated, all buttons are locked, except the button for the child-proof
lock.

Chan in the filter
Changing the main filter:
The frequency with which the filter has to be chan ed depends, of course, on the amount of
contamination and use. As a eneral rule it should normally be chan ed every 6-9 months.
Chan e the filter if the followin problems arise: The performance of the fan drops and the
noise level increases at the same time. The surface of the filter chan es color until it becomes
similar to that of the indicator. If you notice that the filter has ot to a point where it no lon-
er removes much dust and dirt from the air.
• First make sure, that the device is unplu ed. Then put the device on the backside.
• Press the two release buttons at the sides of the filter cartrid e and put it out a little.
• Lift the unit carefully, then the filtercartrid e will slide out by itself.
• Now check the filter by comparin the color. If the filter has not chan ed that much in
color, clean it with a vacuum cleaner (ideally outdoors).

• If the comparison of the colors shows that the filter needs to be chan ed, then chan e
the filter. Replacement filters can be ordered at www.comedes.com.
• The filter chan e indicator only works in a normal home environment. You may have to
chan e the filter earlier if smoke or odor levels are hi her.
• Aller y sufferers are advised to chan e the filter as soon as the chan e lamp comes on
for the first time.
Composite of the filterin system
Useful information:
The filter we use in our device is no different in terms of desi n to the types of filters which are
used extensively in laboratories throu hout the world wherever the creation of absolutely clean
ambient air is a must. We apply exactly the same principle of operation for improvin the air in
your home and office.
The installed filter can filter out up to 99.97% of all microparticles (>0,03μ) from the ambient
air. By way of comparison, the human nose filters out particles bi er than 10μ from the
inhaled air. The back of the filter has a coatin of activated carbon which also effectively eli-
minates odors in the air.
Prefilter
HEPA filter
Active Carbon filter
TiO2 Filter
Filter cartridge

Cleanin the device
Pull out the power plug before starting cleaning
work!
Cleaning the housing:
Do not use a ressive cleanin a ents, just a damp cloth
or neutral cleanin a ent.
Cleaning the air inlets:
Use a vacuum cleaner or dry cloth.
Cleaning the main filter:
The ventilation effect will drop off noticeably if a lot of dust accumulates
on the surface of the filter. You therefore need to clean the filter once
a month. Use a vacuum cleaner to do so, as shown in the illustration.
For information on how to remove the filter, please refer to the section
“Before startin up” at the very be innin of this manual.
Faults and troubleshootin
For our latest operating instructions please go to http://blog.comedes.com
Switch off the device immediately and contact your dealer if any of the followin problems
occur:
• Burned out fuse.
• Extraneous material ets into the device.
• The plu or the power cable et hot.
Do not open the device without authorized service personnel. However, you can check the
followin faults yourself:
The de ice cannot be switched on:
• Is the plu properly connected?
• Has the fuse burned out or is there no volta e supply at the socket outlet?
There is less air flow at the outlet:
• Is the filter too dirty or clo ed?
The equipment is unusually loud:
• Has the device been wall-mounted in an unstable position or are the wall pads missin
at the back?
• Has the device been set up on an uneven surface?

Tips on purifying the air in case of cigarette smoke
Ci arette smoke is comprised of a lar e ran e of complex chemical compounds. For the air
purifier these are essentially divided into the solid and aseous components of the smoke. The
solid smoke particles are filtered out by the HEPA filter. The aseous components are partly
absorbed by the activated carbon filter and partly eliminated by the TIO2 filter.
• To prevent possible dama e to the TIO2 filter, it is important that the main filter is
chan ed in ood time.
• The device needs to be set up as close to the source of smoke as possible.
• The device should not be set up on the floor. (For smokers we recommend wall-
mountin .)
• The device will have a shorter service life dependin on the number of ci arettes
smoked.
Tips on purifying the air in case of problems with pollen
The air purifier is capable of filterin all standard types of pollen out of the air. These remain in
the HEPA filter. To enable the device to work as effectively as possible and si nificantly reduce
the concentration of pollen, we recommend that you create a refu e in which the air purifier
can be stood. The device can only eliminate aller ens which are present in the air, but not
aller ens which have settled on beds, walls, furniture, etc.
Therefore, please follow the instructions below:
• Clean the room thorou hly before usin the device.
• Do not use a dustcloth for cleanin , use a damp cloth instead.
• Clean upholstered furniture with a vacuum cleaner at least once a week. Use a vacuum
cleaner suitable for aller y sufferers.
• Mop the room at least once a week.
• Run the device at settin 1 durin the day. Place the device on a table. Do not place it
on the floor and do not suspend it below the ceilin .
• Switch the device off before oin to sleep.
• Set the fan settin to III while ventilatin . Ventilate the rooms ideally between 6:00
a.m. and 8:00 a.m. in urban areas or after 7:00 p.m. in rural areas.
Tips on purifying the air in case of problems with household dust
Household dust is enerally produced by mites that live in upholstered furniture, cushions,
covers and mattresses. This is where the household dust remains at first. The air purifier can
only remove household dust which is present in the air. It is therefore advisable to seal off the
sources of household dust before you start to use the air purifier.
• Cover mattresses in aller en-proof encasin s.
• Cover pillows and blankets in aller en-proof encasin s.
• Wash pillows and blankets frequently.
• Replace old mattresses.
• Use a vacuum cleaner with a fine filter.
• Vacuum clean mattresses once a month.
• Keep dust catchers out of the bedroom.
• Do not put any indoor plants in the bedroom.

Table of contents
Other Comedes Air Cleaner manuals

Comedes
Comedes Lavaero 1000 User manual

Comedes
Comedes Lavaero 100 User manual

Comedes
Comedes Lavaero 150 ECO User manual

Comedes
Comedes Lavaero 900 User manual

Comedes
Comedes Lavaero 280 User manual

Comedes
Comedes Lavaero 1000 User manual

Comedes
Comedes Lavaero 280 User manual

Comedes
Comedes LR 50 User manual

Comedes
Comedes Lavaero 240 User manual

Comedes
Comedes Lavaero 1200 User manual