Congatec COM Express conga-STX7 User manual

Copyright © 2020 congatec AG DSTXm10 1/75
COM Express™ conga-STX7
Detailed description of the congatec COM Express™ Type 7 carrier board
User’s Guide
Revision 1.0

Copyright © 2020 congatec AG DSTXm10 2/75
Revision History
Revision Date (yyyy-mm-dd) Author Changes
0.1 2020-02-12 AEM •Preliminary release
1.0 2020-07-24 AEM •Added section 6 “BMC Configuration and Management”
•Official release

Copyright © 2020 congatec AG DSTXm10 3/75
Preface
This user’s guide provides information about the components, features and connectors available on the congatec COM Express™ Type 7
carrier board.
Disclaimer
The information contained within this user’s guide, including but not limited to any product specification, is subject to change without notice.
congatec AG provides no warranty with regard to this user’s guide or any other information contained herein and hereby expressly disclaims
any implied warranties of merchantability or fitness for any particular purpose with regard to any of the foregoing. congatec AG assumes
no liability for any damages incurred directly or indirectly from any technical or typographical errors or omissions contained herein or for
discrepancies between the product and the user’s guide. In no event shall congatec AG be liable for any incidental, consequential, special, or
exemplary damages, whether based on tort, contract or otherwise, arising out of or in connection with this user’s guide or any other information
contained herein or the use thereof..
Intended Audience
This user’s guide is intended for technically qualified personnel. It is not intended for general audiences.
Lead-Free Designs (RoHS)
All congatec AG designs are created from lead-free components and are completely RoHS compliant.
Electrostatic Sensitive Device
All congatec AG products are electrostatic sensitive devices. They are enclosed in static shielding bags, and shipped enclosed in secondary
packaging (protective packaging). The secondary packaging does not provide electrostatic protection.
Do not remove the device from the static shielding bag or handle it, except at an electrostatic-free workstation. Also, do not ship or store
electronic devices near strong electrostatic, electromagnetic, magnetic, or radioactive fields unless the device is contained within its original
packaging. Be aware that failure to comply with these guidelines will void the congatec AG Limited Warranty

Copyright © 2020 congatec AG DSTXm10 4/75
Symbols
The following symbols are used in this user’s guide:
Warning
Warnings indicate conditions that, if not observed, can cause personal injury.
Caution
Cautions warn the user about how to prevent damage to hardware or loss of data.
Note
Notes call attention to important information that should be observed.
Connector Type
Describes the connector on the congatec COM Express™ carrier board and possible mating connector.
Link to connector layout diagram
This link icon is located in the top left corner of each page. It provides a direct link to the connector layout diagram on page 8 of this document.
Copyright Notice
Copyright © 2020, congatec AG. All rights reserved. All text, pictures and graphics are protected by copyrights. No copying is permitted
without written permission from congatec AG.
congatec AG has made every attempt to ensure that the information in this document is accurate yet the information contained within is
supplied “as-is”.

Copyright © 2020 congatec AG DSTXm10 5/75
Trademarks
Product names, logos, brands, and other trademarks featured or referred to within this user’s guide, or the congatec website, are the property
of their respective trademark holders. These trademark holders are not affiliated with congatec AG, our products, or our website.
Warranty
congatec AG makes no representation, warranty or guaranty, express or implied regarding the products except its standard form of limited
warranty (“Limited Warranty”) per the terms and conditions of the congatec entity, which the product is delivered from. These terms and
conditions can be downloaded from www.congatec.com. congatec AG may in its sole discretion modify its Limited Warranty at any time and
from time to time.
The products may include software. Use of the software is subject to the terms and conditions set out in the respective owner’s license
agreements, which are available at www.congatec.com and/or upon request.
Beginning on the date of shipment to its direct customer and continuing for the published warranty period, congatec AG represents that the
products are new and warrants that each product failing to function properly under normal use, due to a defect in materials or workmanship or
due to non conformance to the agreed upon specifications, will be repaired or exchanged, at congatec’s option and expense.
Customer will obtain a Return Material Authorization (“RMA”) number from congatec AG prior to returning the non conforming product freight
prepaid. congatec AG will pay for transporting the repaired or exchanged product to the customer.
Repaired, replaced or exchanged product will be warranted for the repair warranty period in effect as of the date the repaired, exchanged
or replaced product is shipped by congatec, or the remainder of the original warranty, whichever is longer. This Limited Warranty extends to
congatec’s direct customer only and is not assignable or transferable.
Except as set forth in writing in the Limited Warranty, congatec makes no performance representations, warranties, or guarantees, either
express or implied, oral or written, with respect to the products, including without limitation any implied warranty (a) of merchantability, (b) of
fitness for a particular purpose, or (c) arising from course of performance, course of dealing, or usage of trade.
congatec AG shall in no event be liable to the end user for collateral or consequential damages of any kind. congatec shall not otherwise be
liable for loss, damage or expense directly or indirectly arising from the use of the product or from any other cause. The sole and exclusive
remedy against congatec, whether a claim sound in contract, warranty, tort or any other legal theory, shall be repair or replacement of the
product only.
Certification
congatec AG is certified to DIN EN ISO 9001 standard.
C
E
R
T
I
F
I
C
A
T
I
O
N
I
S
O
9
0
0
1
TM

Copyright © 2020 congatec AG DSTXm10 6/75
Technical Support
congatec AG technicians and engineers are committed to providing the best possible technical support for our customers so that our products
can be easily used and implemented. We request that you first visit our website at www.congatec.com for the latest documentation, utilities
and drivers, which have been made available to assist you. If you still require assistance after visiting our website then contact our technical
Terminology
Term Description
BMC Board Management Controller
GbE Gigabit Ethernet
HDA High Definition Audio
IPMI Intelligent Platform Management interface
I²C Bus Inter-Integrated Circuit Bus
KCS Keyboard Controller Style
KVM Keyboard, Video and Mouse
MAC Media Access Control
N.A Not available
N.C Not connected
NCSI Network Controller Sideband Interface
PCIe Peripheral Component Interface Express (PCI Express)
SATA Serial AT Attachment
SFP+ Enhanced Small Form-factor Pluggable
SNMP Simple Network Management Protocol
SM Bus System Management Bus
SoL Serial Over LAN
T.B.D To be determined
USB Universal Serial Bus

Copyright © 2020 congatec AG DSTXm10 7/75
Contents
1 Introduction ............................................................................. 10
1.1 COM Express™ Concept......................................................... 10
1.2 conga-STX7 ............................................................................. 10
2 Connector Layout .................................................................... 11
3 Specifications........................................................................... 13
3.1 Feature List .............................................................................. 13
3.2 Mechanical Dimensions ........................................................... 14
3.3 Supply Voltage Power.............................................................. 14
3.4 Environmental Specifications................................................... 14
4 Connector Description............................................................. 15
4.1 Power Supply Connectors........................................................ 19
4.1.1 DC Power Jack......................................................................... 19
4.1.2 Mini-Fit 4-Pin Connector.......................................................... 19
4.1.3 CMOS Battery Connector........................................................ 20
4.1.4 Status LEDs .............................................................................. 20
4.2 Extension Sockets ................................................................... 21
4.2.1 M.2 Key B Socket..................................................................... 21
4.2.2 M.2 Key M Socket.................................................................... 23
4.2.2.1 HDD LED Pin Header............................................................... 24
4.3 Board to Board Connector (PCIe x16) ..................................... 25
4.4 PCI Express®Routing............................................................... 28
4.5 VGA Connector........................................................................ 29
4.6 SFP+ (10 Gbe) Connector........................................................ 30
4.7 RJ45 (1 GbE) Connector .......................................................... 30
4.7.1 PHY/MAC Management Headers............................................ 31
4.8 USB Connector ........................................................................ 32
4.9 UART Header........................................................................... 32
4.9.1 RS232 UART Header................................................................ 32
4.9.2 General Purpose Serial Ports ................................................... 33
4.10 Fan Header .............................................................................. 34
4.11 SPI Flash Socket....................................................................... 34
4.12 Front Panel Header.................................................................. 35
4.13 Feature Connector................................................................... 36
5 BMC Overview......................................................................... 38
5.1 Firmware ................................................................................. 38
5.2 Features ................................................................................... 38
6 BMC Configuration and Management .................................... 40
6.1 Before You Begin ..................................................................... 40
6.2 Enable BMC Support in BIOS Setup Menu ............................. 40
6.3 BMC IP Address....................................................................... 41
6.3.1 Configure IP Using BIOS Setup Menu ..................................... 41
6.3.2 Configure IP Using Ipmitool in Linux ....................................... 44
7 BMC Access and Management................................................ 45
7.1 Local BMC Management (KCS)................................................ 45
7.1.1 Local Access Using BIOS Setup Menu..................................... 45
7.1.2 Local Access Using Ipmitool (Linux)......................................... 46
7.1.2.1 Test the Interface .................................................................... 46
7.1.2.2 Sensor Readings ...................................................................... 47
7.1.2.3 System Event Log ................................................................... 48
7.1.2.4 LAN Configuration Parameters ............................................... 48
7.1.2.5 Chassis Power Control ............................................................ 50
7.2 Remote BMC Management ..................................................... 51
7.2.1 Remote Access Using BMC Web Interface.............................. 51
7.2.1.1 Supported Browsers ................................................................ 51
7.2.1.2 Logging In ............................................................................... 51
7.2.1.3 KVM Remote Control Operation ............................................. 55
7.2.2 Remote Access Using Ipmitool (Linux)..................................... 61
7.2.3 Using Serial Over LAN (SoL) .................................................... 62
7.2.3.1 SoL Configuration .................................................................... 62
7.2.3.2 Using Serial Over LAN (SoL) .................................................... 66
8 Additional Features.................................................................. 72
8.1 Buttons..................................................................................... 72
8.1.1 Power....................................................................................... 72
8.1.2 Reset ........................................................................................ 72

Copyright © 2020 congatec AG DSTXm10 8/75
8.2 PC Speaker .............................................................................. 72
8.3 Ground Test Points................................................................... 73
8.4 SM Bus..................................................................................... 73
8.5 I2C Bus...................................................................................... 73
8.6 LPC Bus.................................................................................... 73
8.7 PWR_OK .................................................................................. 74
8.8 Module Type Detection ........................................................... 74
9 Mechanical Dimensions ........................................................... 75

Copyright © 2020 congatec AG DSTXm10 9/75
List of Tables
Table 1 Feature Summary..................................................................... 13
Table 2 Module Type 7 Connector Pinout—Rows A and B .................. 15
Table 3 Module Type 7 Connector Pinout
—Rows C and D.................. 17
Table 4 X43 Pinout Description ............................................................ 19
Table 5 X44 Pinout Description ............................................................ 19
Table 6 X31/X49 Description ............................................................... 20
Table 7 Status LED Description ............................................................ 20
Table 8 X42 Pinout Description ............................................................ 21
Table 9 X40/X41 Pinout Description .................................................... 23
Table 10 Header X39 Pinout Description ............................................... 24
Table 11 X48 Pinout Description ............................................................ 25
Table 12 X13 Pinout Description ............................................................ 29
Table 13 GbE Pinout Description ........................................................... 30
Table 14 X3 Pinout Description .............................................................. 31
Table 15 X14 Pinout Description ............................................................ 31
Table 16 X25/X26 Pinout Description .................................................... 32
Table 17 Possible Serial Port Configuration ........................................... 33
Table 18 SW3 Pinout Description........................................................... 33
Table 19 X36/X38 Pinout Description .................................................... 34
Table 20 M19 Pinout Description ........................................................... 35
Table 21 X50/X51/X52 Pinout Description............................................. 35
Table 22 X32 Pinout Description ............................................................ 36
Table 23 MegaRAC Menu Bar Description............................................. 54
Table 24 Ipmitool Remote Commands................................................... 61
Table 25 Module Type Detection Pinout Description............................. 74

Copyright © 2020 congatec AG DSTXm10 10/75
1 Introduction
1.1 COM Express™ Concept
COM Express™ is an open industry standard defined specifically for COMs (computer on modules). Its creation makes it possible to smoothly
transition from legacy interfaces to the newest technologies available today.
A Computer On Module integrates all the core components and standard I/O interfaces of a common PC onto an application specific carrier
board. The key advantage of the COM in the embedded computer industries is that all the highly-integrated, high-speed components such as
CPU, chipsets and memory are combined on a small module form factor for easy adaptation into different applications across multiple market
segments.
COM Express™ modules have standardized form factors and specified pinouts on the two system connectors that remain the same regardless
of the vendor. The COM Express™ module reflects the functional requirements for a wide range of embedded applications. These functions
include, but are not limited to PCI Express, graphics, high definition audio, serial ATA, gigabit Ethernet and USB ports. Two ruggedized,
shielded connectors provide the carrier board interface and carry all the I/O signals to and from the COM Express™ module.
Carrier board designers can use as little or as many of the I/O interfaces as deemed necessary. The carrier board can therefore provide all the
interface connectors required to attach the system to the application specific peripherals. This versatility allows the designer to create a dense
and optimized package. The result is a more reliable product with simplified system integration.
Most importantly, COM Express™ modules are scalable. Once an application has been created, the product range can be diversified by using
different performance class or form factor size modules. Simply unplug one module and replace it with another; no redesign is necessary.
1.2 conga-STX7
The conga-STX7 carrier board design is based on Type 7 pinout definition and it complies with COM Express Specification 3.0. The carrier
board comes in Intel Mini-STX form factor and supports COM Express Type 7 compact and basic form-factor modules.
The conga-STX7 provides most of the functional requirements for server application. These functions include, but are not limited to a rich
complement of contemporary high bandwidth interfaces such as PCI Express, Serial ATA, USB 3.0/2.0, and 10 Gb SFP+.
By combining the scalability of COM Express modules, the conga-STX7 carrier board provides manufacturers and developers with a platform
to jump-start the development of systems and applications based on COM Express Type 7 specification. This helps to reduce product design
cycle and encourages rapid innovation in system design, to meet the ever-changing needs of the market.

Copyright © 2020 congatec AG DSTXm10 11/75
2 Connector Layout
The connector layout picture shows each
connector and its designator.
Select the Adobe ‘Zoom-In-Tool’ and
zoom in on a given component to see its
designator. Hover over the component
and the ‘Zoom-In-Tool’ will change
indicating there is a link.
Click on the link to navigate to the area
in the document where the component
is described.
Use the mouse icon in the top left hand
corner of the destination page to return
to the connector layout picture.
Lower
UpperUpper
Lower
X18 X20 X15 X17
X21
X43
X22
X44
X36
X38
M19
21
X3
X1
X2
M7 M12
M11
X19 X16
D10 D47 D13 D48 D4 D45 D7 D46
M6
X26
X25
M5
X51 X52 X50 X39
D30
X49 X31
X32
D1
9 9
2 10 2 10
ON

Copyright © 2020 congatec AG DSTXm10 13/75
3 Specifications
3.1 Feature List
Table 1 Feature Summary
Form Factor Based on Intel Mini-STX form factor (147 mm by 140 mm)
Part Number 065450
Supported Modules COM Express™ Type 7 compact and basic form factor
Operating
Temperature Range
-40°C to 85°C
Ethernet Gigabit Ethernet with support for:
-4x 10 Gb SFP+ (Inphy CS4227)
-3x 1 Gb RJ45
Board Management
Controller
ASPEED AST2500
Graphics VGA from BMC
Back Panel I/O
Connectors
4x 10 Gbe SFP+
3x 1 Gbe RJ45 1
2x USB 3.1 Gen 2
12 V DC input
Onboard I/O
Connectors
1x Board to board PCIe x16 connector for add-on cards
Extension Sockets:
-2x M.2 key M, type 2280 (PCIe x4/SATA)
-1x M.2 key B, type 3042 (PCIe x2/USB/I2C) 2
COM Express Type 7 connectors
2x RS232 UART
1x Mini-Fit power connector
1x Feature connector (power button, reset,sleep, watchdog, GPIO,
serial ports 0-1, SMB/I2C)
1x CPU fan
1x System fan
1x VGA (via the BMC)
1x SOIC8 for flashing external BIOS
IPMI Baseboard Management Controller
Intelligent Platform Interface 2.0 (IPMI 2.0)
KVM, media redirection
IPMI over LAN
Serial over LAN
Software AMI Megarc SPX BMC firmware
32 MB serial SPI flash with congatec Embedded BIOS features
Other Features Buzzer
Thermal and voltage monitoring
CMOS Battery
Boot from external BIOS flash
Optional Features BMC UART
Status LEDs powered from S0

Copyright © 2020 congatec AG DSTXm10 14/75
Note
1. The GbE port X21 supports only BMC management (no support for network connectivity)
2. Supports PCIe x1 if the module’s gigabit Ethernet is enabled
3.2 Mechanical Dimensions
The conga-STX7 has the following dimensions:
•lenght of 147 mm
•width of 140 mm
•height of 38.2 mm (30.8 mm top-side, 2 mm PCB and 5.4 mm bottom-side)
3.3 Supply Voltage Power
•12 V DC ± 10 %
3.4 Environmental Specifications
Temperature Operation: 0°C to 60°C Storage: -40° to +85°C (commercial temperature)
Temperature Operation: -40°C to 85°C Storage: -40° to +85°C (industrial temperature)
Humidity Operation: 10% to 90% Storage: 5% to 95%
Note
The above operating temperatures must be strictly adhered to at all times. The maximum operating temperature refers to any measurable
spot on the modules surface.
Humidity specifications are for non-condensing conditions.

Copyright © 2020 congatec AG DSTXm10 15/75
4 Connector Description
Table 2 Module Type 7 Connector Pinout—Rows A and B
Pin Row A Pin Row B Pin Row A Pin Row B
A1 GND (FIXED) B1 GND (FIXED) A56 PCIE_TX4- B56 PCIE_RX4-
A2 GBE0_MDI3- B2 GBE0_ACT# A57 GND B57 GPO2
A3 GBE0_MDI3+ B3 LPC_FRAME#/ESPI_CS0# A58 PCIE_TX3+ B58 PCIE_RX3+
A4 GBE0_LINK100# B4 LPC_AD0/ESPI_IO_0 A59 PCIE_TX3- B59 PCIE_RX3-
A5 GBE0_LINK1000# B5 LPC_AD1/ESPI_IO_1 A60 GND (FIXED) B60 GND (FIXED)
A6 GBE0_MDI2- B6 LPC_AD2/ESPI_IO_2 A61 PCIE_TX2+ B61 PCIE_RX2+
A7 GBE0_MDI2+ B7 LPC_AD3/ESPI_IO_3 A62 PCIE_TX2- B62 PCIE_RX2-
A8 GBE0_LINK# B8 LPC_DRQ0#/ESPI_ALERT0# A63 GPI1 B63 GPO3
A9 GBE0_MDI1- B9 LPC_DRQ1#/ESPI_ALERT1# A64 PCIE_TX1+ B64 PCIE_RX1+
A10 GBE0_MDI1+ B10 LPC_CLK/ESPI_CK A65 PCIE_TX1- B65 PCIE_RX1-
A11 GND(FIXED) B11 GND (FIXED) A66 GND B66 WAKE0#
A12 GBE0_MDI0- B12 PWRBTN# A67 GPI2 B67 WAKE1# 2
A13 GBE0_MDI0+ B13 SMB_CK A68 PCIE_TX0+ B68 PCIE_RX0+
A14 GBE0_CTREF B14 SMB_DAT A69 PCIE_TX0- B69 PCIE_RX0-
A15 SUS_S3# B15 SMB_ALERT# A70 GND (FIXED) B70 GND (FIXED)
A16 SATA0_TX+ B16 SATA1_TX+ A71 PCIE_TX8+ B71 PCIE_RX8+
A17 SATA0_TX- B17 SATA1_TX- A72 PCIE_TX8- B72 PCIE_RX8-
A18 SUS_S4# B18 SUS_STAT#/ESPI_RESET# A73 GND B73 GND
A19 SATA0_RX+ B19 SATA1_RX+ A74 PCIE_TX9+ B74 PCIE_RX9+
A20 SATA0_RX- B20 SATA1_RX- A75 PCIE_TX9- B75 PCIE_RX9-
A21 GND (FIXED) B21 GND (FIXED) A76 GND B76 GND
A22 PCIE_TX15+ 1B22 PCIE_RX15+ 1A77 PCIE_TX10+ B77 PCIE_RX10+
A23 PCIE_TX15- 1B23 PCIE_RX15- 1A78 PCIE_TX10- B78 PCIE_RX10-
A24 SUS_S5# B24 PWR_OK A79 GND B79 GND
A25 PCIE_TX14+ 1B25 PCIE_RX14+ 1A80 GND (FIXED) B80 GND (FIXED)
A26 PCIE_TX14- 1B26 PCIE_RX14- 1A81 PCIE_TX11+ B81 PCIE_RX11+
A27 BATLOW# B27 WDT A82 PCIE_TX11- B82 PCIE_RX11-
A28 (S)ATA_ACT# B28 RSVD 1A83 GND B83 GND
A29 RSVD 1B29 RSVD 1A84 NCSI_TX_EN B84 VCC_5V_SBY

Copyright © 2020 congatec AG DSTXm10 16/75
Pin Row A Pin Row B Pin Row A Pin Row B
A30 RSVD 1B30 RSVD 1A85 GPI3 B85 VCC_5V_SBY
A31 GND (FIXED) B31 GND (FIXED) A86 RSVD 1B86 VCC_5V_SBY
A32 RSVD 1B32 SPKR A87 RSVD 1B87 VCC_5V_SBY
A33 RSVD 1B33 I2C_CK A88 PCIE_CK_REF+ B88 BIOS_DIS1#
A34 BIOS_DIS0#/ESPI_SAFS B34 I2C_DAT A89 PCIE_CK_REF- B89 NCSI_RX_ER 2
A35 THRMTRIP# B35 THRM# A90 GND (FIXED) B90 GND (FIXED)
A36 PCIE_TX13+ 1B36 PCIE_RX13+ 1A91 SPI_POWER B91 NCSI_CLK_IN
A37 PCIE_TX13- 1B37 PCIE_RX13- 1A92 SPI_MISO B92 NCSI_RXD1
A38 GND B38 GND A93 GPO0 B93 NCSI_RXD0
A39 PCIE_TX12+ 1B39 PCIE_RX12+ 1A94 SPI_CLK B94 NCSI_CRS_DV
A40 PCIE_TX12- 1B40 PCIE_RX12- 1A95 SPI_MOSI B95 NCSI_TXD1
A41 GND (FIXED) B41 GND (FIXED) A96 TPM_PP 2B96 NCSI_TXD0
A42 USB2- B42 USB3- A97 TYPE10# B97 SPI_CS#
A43 USB2+ B43 USB3+ A98 SER0_TX B98 NCSI_ARB_IN 2
A44 USB_2_3_OC# 2B44 USB_0_1_OC# A99 SER0_RX B99 NCSI_ARB_OUT 2
A45 USB0- B45 USB1- A100 GND (FIXED) B100 GND (FIXED)
A46 USB0+ B46 USB1+ A101 SER1_TX B101 FAN_PWMOUT
A47 VCC_RTC B47 ESPI_EN# A102 SER1_RX B102 FAN_TACHIN
A48 RSVD 1B48 USB0_HOST_PRSNT 1A103 LID# B103 SLEEP#
A49 GBE0_SDP 1B49 SYS_RESET# A104 VCC_12V B104 VCC_12V
A50 LPC_SERIRQ/ESPI_CS1# B50 CB_RESET# A105 VCC_12V B105 VCC_12V
A51 GND (FIXED) B51 GND (FIXED) A106 VCC_12V B106 VCC_12V
A52 PCIE_TX5+ B52 PCIE_RX5+ A107 VCC_12V B107 VCC_12V
A53 PCIE_TX5- B53 PCIE_RX5- A108 VCC_12V B108 VCC_12V
A54 GPI0 B54 GPO1 A109 VCC_12V B109 VCC_12V
A55 PCIE_TX4+ B55 PCIE_RX4+ A110 GND (FIXED) B110 GND (FIXED)
Note
1. Not connected
2. Not supported

Copyright © 2020 congatec AG DSTXm10 17/75
Table 3 Module Type 7 Connector Pinout
—Rows C and D
Pin Row C Pin Row D Pin Row C Pin Row D
C1 GND (FIXED) D1 GND (FIXED) C56 PCIE_RX17- D56 PCIE_TX17-
C2 GND D2 GND C57 TYPE1# D57 TYPE2#
C3 USB_SSRX0- D3 USB_SSTX0- C58 PCIE_RX18+ D58 PCIE_TX18+
C4 USB_SSRX0+ D4 USB_SSTX0+ C59 PCIE_RX18- D59 PCIE_TX18-
C5 GND D5 GND C60 GND (FIXED) D60 GND (FIXED)
C6 USB_SSRX1- D6 USB_SSTX1- C61 PCIE_RX19+ D61 PCIE_TX19+
C7 USB_SSRX1+ D7 USB_SSTX1+ C62 PCIE_RX19- D62 PCIE_TX19-
C8 GND D8 GND C63 RSVD D63 RSVD
C9 USB_SSRX2- D9 USB_SSTX2- C64 RSVD D64 RSVD
C10 USB_SSRX2+ D10 USB_SSTX2+ C65 PCIE_RX20+ D65 PCIE_TX20+
C11 GND(FIXED) D11 GND (FIXED) C66 PCIE_RX20- D66 PCIE_TX20-
C12 USB_SSRX3- D12 USB_SSTX3- C67 RAPID_SHUTDOWN D67 GND
C13 USB_SSRX3+ D13 USB_SSTX3+ C68 PCIE_RX21+ D68 PCIE_TX21+
C14 GND D14 GND C69 PCIE_RX21- D69 PCIE_TX21-
C15 10G_PHY_MDC_SCL3 D15 10G_PHY_MDIO_SDA3 C70 GND (FIXED) D70 GND (FIXED)
C16 10G_PHY_MDC_SCL2 D16 10G_PHY_MDIO_SDA2 C71 PCIE_RX22+ D71 PCIE_TX22+
C17 10G_SDP2 2D17 10G_SDP3 2C72 PCIE_RX22- D72 PCIE_TX22-
C18 GND D18 GND C73 GND D73 GND
C19 PCIE_RX6+ D19 PCIE_TX6+ C74 PCIE_RX23+ D74 PCIE_TX23+
C20 PCIE_RX6- D20 PCIE_TX6- C75 PCIE_RX23- D75 PCIE_TX23-
C21 GND (FIXED) D21 GND (FIXED) C76 GND D76 GND
C22 PCIE_RX7+ D22 PCIE_TX7+ C77 RSVD D77 RSVD
C23 PCIE_RX7- D23 PCIE_TX7- C78 PCIE_RX24+ D78 PCIE_TX24+
C24 10G_INT2 D24 10G_INT3 C79 PCIE_RX24- D79 PCIE_TX24-
C25 GND D25 GND C80 GND (FIXED) D80 GND (FIXED)
C26 10G_KR_RX3+ D26 10G_KR_TX3+ C81 PCIE_RX25+ D81 PCIE_TX25+
C27 10G_KR_RX3- D27 10G_KR_TX3- C82 PCIE_RX25- D82 PCIE_TX25-
C28 GND D28 GND C83 RSVD D83 RSVD
C29 10G_KR_RX2+ D29 10G_KR_TX2+ C84 GND D84 GND
C30 10G_KR_RX2- D30 10G_KR_TX2- C85 PCIE_RX26+ D85 PCIE_TX26+
C31 GND (FIXED) D31 GND (FIXED) C86 PCIE_RX26- D86 PCIE_TX26-

Copyright © 2020 congatec AG DSTXm10 18/75
Pin Row C Pin Row D Pin Row C Pin Row D
C32 10G_SFP_SDA3 D32 10G_SFP_SCL3 C87 GND D87 GND
C33 10G_SFP_SDA2 D33 10G_SFP_SCL2 C88 PCIE_RX27+ D88 PCIE_TX27+
C34 10G_PHY_RST_23 D34 10G_PHY_CAP_23 C89 PCIE_RX27- D89 PCIE_TX27-
C35 10G_PHY_RST_01 D35 10G_PHY_CAP_01 C90 GND (FIXED) D90 GND (FIXED)
C36 10G_LED_SDA D36 RSVD C91 PCIE_RX28+ D91 PCIE_TX28+
C37 10G_LED_SCL D37 RSVD C92 PCIE_RX28- D92 PCIE_TX28-
C38 10G_SFP_SDA1 D38 10G_SFP_SCL1 C93 GND D93 GND
C39 10G_SFP_SDA0 D39 10G_SFP_SCL0 C94 PCIE_RX29+ D94 PCIE_TX29+
C40 10G_SDP0 2D40 10G_SDP1 2C95 PCIE_RX29- D95 PCIE_TX29-
C41 GND (FIXED) D41 GND (FIXED) C96 GND D96 GND
C42 10G_KR_RX1+ D42 10G_KR_TX1+ C97 RSVD D97 RSVD
C43 10G_KR_RX1- D43 10G_KR_TX1- C98 PCIE_RX30+ D98 PCIE_TX30+
C44 GND D44 GND C99 PCIE_RX30- D99 PCIE_TX30-
C45 10G_PHY_MDC_SCL1 D45 10G_PHY_MDIO_SDA1 C100 GND (FIXED) D100 GND (FIXED)
C46 10G_PHY_MDC_SCL0 D46 10G_PHY_MDIO_SDA0 C101 PCIE_RX31+ D101 PCIE_TX31+
C47 10G_INT0 D47 10G_INT1 C102 PCIE_RX31- D102 PCIE_TX31-
C48 GND D48 GND C103 GND D103 GND
C49 10G_KR_RX0+ D49 10G_KR_TX0+ C104 VCC_12V D104 VCC_12V
C50 10G_KR_RX0- D50 10G_KR_TX0- C105 VCC_12V D105 VCC_12V
C51 GND (FIXED) D51 GND(FIXED) C106 VCC_12V D106 VCC_12V
C52 PCIE_RX16+ D52 PCIE_TX16+ C107 VCC_12V D107 VCC_12V
C53 PCIE_RX16- D53 PCIE_TX16- C108 VCC_12V D108 VCC_12V
C54 TYPE0# D54 RSVD C109 VCC_12V D109 VCC_12V
C55 PCIE_RX17+ D55 PCIE_TX17+ C110 GND (FIXED) D110 GND (FIXED)
Note
1. Not connected
2. Not supported

Copyright © 2020 congatec AG DSTXm10 19/75
4.1 Power Supply Connectors
The conga-STX7 provides a DC power jack and a 4-pin Mini-Fit connector. The power input is protected by a 15A fuse.
4.1.1 DC Power Jack
The conga-STX7 provides a DC power jack X43. The power input is protected by a 15 A fuse.
Table 4 X43 Pinout Description
Pin Function
Inner Shell +12 V ± 10%
Outer Shell GND
Connector Type
X43 : DC power jack, 7.4 x 5.1 mm diameter
4.1.2 Mini-Fit 4-Pin Connector
The conga-STX7 provides an internal 4-pin Mini-Fit connector X44 with voltage protection.
Table 5 X44 Pinout Description
Pin Signal Description
1 GND Ground
2 GND Ground
3 +12 V Power supply +12 V
4 +12 V Power supply +12 V
Connector Type
X44 : 2 x 2-pin, 4.2 mm pitch Mini-Fit connector (Molex 87427-0442)
Possible Mating Connector: Molex 39012040
X43
X44
1
2
3
4

Copyright © 2020 congatec AG DSTXm10 20/75
4.1.3 CMOS Battery Connector
The conga-STX7 provides battery holder M20 for attaching CR2032 CMOS battery. The battery supplies power to maintain the CMOS settings
and real time clock.
Use jumper X31 to connect the RTC battery and jumper X49 to disconnect the RTC battery.
Table 6 X31/X49 Description
Jumper Description
X31 Jumper connects RTC battery (default)
X49 Jumper disconnects the RTC battery
Warning
Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer’s instructions.
Connector Type
X31, X49: 2.54mm, 1 x 2-pin header
4.1.4 Status LEDs
The table below describes the conga-STX7 status LEDs.
Table 7 Status LED Description
LED Color Status Description
Power All Off No power applied to board and BMC
BMC Heatbeat D1 Green On (blinking) BMC activity is detected. In BMC normal operation, the LED blinks at an interval of 0.5 s.
Constant blinking indicates blank SPI ROM or abnormal operation.
Off BMC is not active
HDD D30 Yellow On (blinking) Disk activity detected
Off No disk activity detected
M20
X31/X49
2
1
This manual suits for next models
1
Table of contents