4. CongurationofCP1000
4.1 Service code
4.2 Congurationoverview
4.3 Change Master code
4.4 Change Service code
4.5 LED indications
4.6 Outputs
4.7 Special settings
5. One-time-/day code
6. Blocking
7. Manual reset
8. Technicalspecications
9. Connection examples
page 3
page 3
page 4
page 4
page 4
page 5
page 6
page 6
page 7
page 7
page 7
page 7
page 8
page 8
page 9
page 10
page 11
page 12
page 12
page 12
page 13

3
1. Introduction
CP1000isaexiblekeypadandproximityreaderinoneunitformaydierentapplica-
tions.
In standby the yellow LED is lit (● ○ ○)
By correct code/tag lights the yellow and green LED (●● ○)
By incorrect code/tag lights the red LED (○ ○ ●)
CP1000 has a buzzer for indicating while keying, correct code/tag, incorrect etc. and
2 transistor outputs, independant from each other, so the CP1000 can give access by
code and proximity tag.
The CP1000 is a stand alone unit, that can be programmed directly by Master code
and Service code.
2. Installation
Mountthereaderonaevensurface(usethefollowingdrilltemplateforpreciset-
ting).
Connect the wires to power supply, door strike, assembly board etc.
Note: Right after applying the voltage all LED’s lights and the buzzer sounds do not
touch the reader untill the yellow LED is lit and the buzzer is silent.
See connection examples og page 13.
9 - 25 VDC / 30 mA
0V GND
Output 2 open collector, 500 mA, 0V active
External controlling green LED, 0V active
Output 1 open collector 500 mA, 0V active
External buzzer / high security
External controlling red LED, 0V active
REX, 0V active
CT 2000 Prox
ALARM SYSTEM A/S
Prox
1 3
5
7 9
2
4 6
8
0

3. Programming users
Programming the CP1000 is simple and easy to understand.
3.1 User positions
CP1000 has 200 positions, which can contain a code or a proximity tag. The positions
are divided as following:
User position Function
1 - 100 Activates output 2 (the code in position 1 is 1234 - factory default).
101 - 150 Activates output 1.
151 - 190 Activates output 1 and 2.
191 - 200 Reserved for special functions.
3.2 Programming user codes
The Master code is used to program/change/delete the users. By default the Master
code is 4711.
LED indication: No light: ○ Light: ● Flash: * Clear buer:
New users
(4711 - standard) ○ ● ○ ●● ○ ●● ○ ○ ● ○
To program more users, continue for “Key in the user positions” or press
to leave the programming mode. ● ○ ○
Changing user codes
It’s the same procedure as programming new users, just overwrite the user positions.
#
Key in the
Master code #
Key in the
user position #
Key in the
user code
#
4

5
Delete specic users
(4711 - standard) ○ ● ○ ●● ○ ○ ● ○ ● ○ ○
Delete all users
(4711 - standard) ○ ● ○ ○ ○ ●
○ ●
● ○ ○
3.2 Programming proximity tags
CP1000 can reader Atmel and Emarine tags.
Programming a new proximity tag
(4711 - standard) ○ ● ○ ●● ○ ●● ○ ○ ● ○
For more proximity tags, continue from “Key in the user position or press
to leave the programming mode. ● ○ ○
Changing proximity tags
It’s the same procedure as programming new users, just overwrite the user position.
Delete a specic proximity tag
(4711 - standard) ○ ● ○ ●● ○ ○ ● ○ ● ○ ○
#
Key in the
Master code #
Key in the
user positions ##
#
Key in the
Master code #
Key in
2500 #
#
Key in the
Master code #
Key in the
user position #
Show
proximity tag
#
#
Key in the
Master code #
Key in the
user position #
#

6
3.4 Programming codes/proximity tags for special functions
Programming the codes and proximity tags is described in 3.2 and 3.3. This entry acti-
vates the output(s) for 5 seconds (factory default). Only 1 user can enter at the time.
Programming the same user twice
By programming the same code/proximity tag on the same position twice toggles the
output.
(Ie. the code/proximity tag is entered to unlock a door and entered to lock it again).
Programming the same user 3 times
By programming the same code/proximity tag on the same position 3 times, the out-
put is designated as switch on only.
(Ie. the code/proximity tag is permanently unlocked when the code/proximity tag is en-
tered).
Programming the same user 4 times
By programming the same code/proximity tag on the same position 4 times, the out-
putisdesignatedasswitchoonly.
(Ie. the door is locked when the code/proximity tag is entered).
3.5 Smart reading
This position makes it possible to program codes/proximity tags quickier without
entering new user positions. Key in a user position and it counts automatically to the
next position. Codes and proximity tags can be programmed alternatively as you see
t.
○ ● ○ *● ○ * ○ ○ For more
codes/tags
repeat from
here
Note: This programming mode overwrites existing user positions.
#
Key in the
Master code #
Key in
05 #
Key in the start
position #
Key in the code
or show tag

7
4.CongurationofCP1000
4.1 Service code
The Service code is used for CP1000’s advanced settings such as changing the MAster
code and Service code, LED indications and much more. the overview of the settings
and the factory settings can be seen in 4.2 Conguration overview.
The Service code is 12347890 (factory default).
Note: Before the Service code can be used must the voltage be turned OFF and
ON (the Service code can now be entered within 10 seconds).
After entering the Service code the reader is in programming mode (the green LED is
lit). Each time a setting is made the CP1000 goes back to the previous point and the
next setting can be made.
The navigation is by entering the position / value followed by #.
4.2Congurationoverview
Position Setting Factory default
00 Master code (1 to 8 digits) 4711
01 Service code (1 to 8 digits) 12347890
02 LED indications Normal = Yellow, active = Yellow and green
03 Outputs Output time for 1 and 2 is 5 seconds
04 Special functions
05 Smart reading
06 Background light
07 Onetime-/day code
2500 Alle codes/proximity tags on the user positions are deleted
0250 Reset to factory default
4.3 Change the Master code
By default the Master code is 4711 and can only be used to program, change or delete
users on CP1000.
To change the Master code, enter the following:
○ ● ○ ●● ○ ○ ● ○
#
Key in the
Service code #
Key in
00 #
Key in a new
code or show tag

4.4 Change the Service code
TheServicecodeisusedtoconguratetheCP1000’ssettings.
To change the Service code, enter the following within 10 seconds after power on:
○ ● ○ ●● ○ ** ○ ○ ● ○
4.5 LED indications
The CP1000’s 3 LED’s can be adjusted at will.
To adjust the LED indications enter the following:
adjust the LED’s for standby indication (normal).
adjust the LED’s for correct code/tag indication (active).
adjust the keying indication (how the LED will react while keying).
To adjust the LED’s press on the following:
= yellow LED (toggle by press)
= green LED (toggle by press)
= red LED (toggle by press)
= buzzer (works only on active and keying indication( toggle by press))
= save and go one step back
To save the settings press or press / . to go back to the previous
point (not saving).
#
Key in the
Service code #
Key in
01 #
Key in a new
code or show tag #
Repeat new
code/tag
#
02
#
1
#
2
#
3
1
2
3
0
#
8
***
***
***
***
#*

4.6 Outputs
The CP1000 has 2 transistor outputs, which both are activated for 5 seconds (factory
default) when a correct code/proximity tag is entered. The output activations time can
be changed and inverted.
To change these settings key in:
activation time for output 1 (white core)
activation time for output 2 (yellow core)
The time is set as:
● ○ ○ ○ ● ○ ○ ○ ●
If no value is entered in hours, minutes or seconds is the value automatically 0 (which
corresponds to set the output as toggle).
bonding the positions and output 1
bonding the positions and output 2
Bothoutputsarebondedtospecicpositions.Byfactorydefaultpositions1to100
and bonded to output 2 and positions 101 to 150 to output 1.
The value can not be crossed.
inverted outputs
output 1 (● ○ ○ = inverted / ○ ○ ○ = not inverted)
output 2 (○ ● ○ = inverted / ○ ○ ○ = not inverted)
To save the settings press or press / . to go back to the previous
point (not saving).
9
#
03
#
1
#
2
○ ●●
#
Key in hours
0 to 60 #
Key in minutes
0 to 60 #
Key in seconds
0 to 60
#
3
#
4
#
5
1
2
#*

4.7 Special functions
These settings is used to change the CP1000’s special functions such as turning the
buzzeron/o,enableHighSecurityetc.
To change these settings, key in:
= Service code without timeout (●= inactive / ●= active)
= The Master code can be changed by Master code (●= inactive / ●= active)
= Mute reader (●=o/●= on)
= Brown core function (●= external buzzer / ●=HighSecurity)
=HighSecurity(●= inaktiv / ●= aktiv)
= Bell/star key (●=deletesnon-nishedcodes/●= activates output 1*)
*When the bell/star key is set to activate output 1 can codes and proximity tags only activates out-
put 1.
High Security
HighSecurityincreasestheCP1000’ssecuritybyensuring2positionshavetobeacti-
vated before the output is activated (the positions must be next to each other).
Special positions
On positions 191 to 194 special functions can be activated by code/proximity tag. The
programming is like programming a new user.
191 = No buzzer.
192=Input1(browncore)function(HighSecurityorexternalbuzzer).
193=HighSecurity.
194 = Bell/star key function (activates output 2 by press).
To save the settings press or press / . to go back to the previous
point (not saving).
Note: A power cut puts the functions back to the settings made by the Service code.
10
#
04
●○ ○
1
2
3
4
5
6
#*

5. One-time-/day code
TheCP1000oers2advancedfunctionsofcodesthatcanbeusedonceonlyanda
code that is valid for a single day.
First the codes have to be generated using the ConlanCode Generator (download
available from www.conlan.eu or on itunes and Google Play).
Enteraseednumberintotherstbox.Thiscanbeanynumberfrom1to9999999.
Then enter the numbers of digits you require the code to have (best to avoid 4 or 8
digitscodessothereisnochanceofconictwithServicecodeorMastercode.The
system defaults to a 6 digit code.
Once you press the enter key, the day code will be shown on the left and a series of
one-timecodesshowninthetablebelow.Boththesecanbeexportedtoaleifre-
quired.
Whentheinformationisspecied,theCP1000canbeset:
Setting the time
○ ● ○ ● ○ ○ ○ ● ○ ●● ○
○ ○ ●● ○ ●○ ● ○
Activation of One-time-/day code
●**●= on, ● = o ○ ● ○ ● ○ ○
Finally, the reader must know how many digits the one-time-/day codes have and the
seed number. This is done in the same way as programming a user code: Position 198
is for seed and position 199 is for digits.
11
#
Key in the
Service code #
Key in
07 #
Key in year
4 digits #
Key in month
2 digits
#
Key in day
2 digits #
Key in hours
2 digits #
Key in minutes
2 digits
#
Key in
04 #
Key in 7for one-time
code or 8for day code #
Conlan Code
Generator for
Windows, for
administration
of one-time and
day codes.
Conlan Day
Code app for
iOS and An-
droid units for
administration
of day codes
with SMS and
Email notica-
tion.

6. Blocking
The CP1000 is blocked for 1 minute after 4 incorrect codes/proximity tags.
LED indication: ○ ○ *
7. Manual reset
The CP1000 can be reset to factory default manually.
•Turnthevoltageo
•Connecttheyellowandbrowncore
•Turnthevoltageon(9-25VDC)thereadersLED’slightsandthebuzzersounds
•Turnthevoltageoanddisconnecttheyellowandbrowncore
The CP1000 is now reset to factory default and the user codes/tags are deleted.
8.Technicalspecications
Voltage: By12VDC,30mA
Voltagerange: 9-25VDC
Proximity reading: Max. 20 mm
Output: 2 pcs, open collector, max. 500 mA
Input: Externalbuzzer/HighSecurity(brown)andREX,0Vactive(blue)
Protection rate: IP67
Color: Black or white
Cable: 2,5 m white, 8 cores
Dimensions(HxWxD): Mykey=76x49x8mm/Classic=130x50x8mm
12

9. Connection examples
Direct connection
Indirect connection
+12V DC
0V DC
REX, 0V active
High Security/external buzzer, 0V active
External controlling green LED, 0V active
External controlling red LED, 0V active
CT 2000 Prox
ALARM SYSTEM A/S
Prox
1 3
5
7 9
2
4 6
8
0
0V GND
Doorstrike
+ 12V DC
+ 12V DC
0V GND
Doorstrike
+ 12V DC
+ 12V DC
+12V DC
0V DC
REX, 0V active
Hight Security/external buzzer, 0V active
Relay
External controlling green LED, 0V active
External controlling red LED, 0V active
CT 2000 Prox
ALARM SYSTEM A/S
Prox
1 3
5
7 9
2
4 6
8
0
NO
NC
C
Relay
0V GND
Doorstrike
+ 12V DC
+ 12V DC
0V
+ 12V DC

Code overview
User Code User Code User Code
1 35 69
2 36 70
3 37 71
4 38 72
5 39 73
6 40 7
7 41 75
8 42 76
9 43 77
10 44 78
11 45 79
12 46 80
13 47 81
14 48 82
15 49 83
16 50 84
17 51 85
18 52 86
19 53 87
20 54 88
21 55 89
22 56 90
23 57 91
24 58 92
25 59 93
26 60 94
27 61 95
28 62 96
29 63 97
30 64 98
31 65 99
32 66 100
33 67 101
34 68 102
14

Code overview
User Code User Code User Code
103 136 169
104 137 170
105 138 171
106 139 172
107 140 173
108 141 174
109 142 175
110 143 176
111 144 177
112 145 178
113 146 179
114 147 180
115 148 181
116 149 182
117 150 183
118 151 184
119 152 185
120 153 186
121 154 187
122 155 188
123 156 189
124 157 190
125 158 191
126 159 192
127 160 193
128 161 194
129 162 195
130 163 196
131 164 197
132 165 198
133 166 199
134 167
135 168

secure open
Conlan ApS • Speditorvej 2A • DK-9000 Aalborg • Tel: +45 72 40 60 03 • Fax: +45 96 32 00 22
www.conlan.eu • [email protected]
Thank you for choosing Conlan’s products.
For further assistance, please contact
Our support service.
This manual suits for next models
1
Table of contents
Other Conlan Keypad manuals
Popular Keypad manuals by other brands

GE
GE NetworX NX-1600E Series user manual

Bosch
Bosch D1260 Series installation guide

DMP Electronics
DMP Electronics 7800 International Series Installation and programming guide

Universal Remote Control
Universal Remote Control Total Control TKP-7000 owner's manual

Invertek Drives
Invertek Drives OPTIPAD user guide

Elk Products
Elk Products Cross Platform Control ELK-M1KP user guide