Conlan CM1000 User manual

User manual
CM1000_usermanual_ENGjan17
Code & Mifare
CM1000
Mykey - Art. No: 480010 (black), 480011 (white)
Classic - Art. No.: 482010 (black), 482011 (white)

2
Table of contents
1. Introduction
2. Installation
3. Programming users
3.1 User positions
3.2 Programming user codes
3.3 Programming Mifare tags
3.4 Programming codes/Mifare tags for
special functions
3.5 Smart reading
4. CongurationofCM1000
4.1 Service code
4.2 Congurationoverview
4.3 Change the Master code
4.4 Change the Service code
4.5 LED Indications
4.6 Outputs
4.7 Special settings
5. Backup card
6. Blocking
7. Manual reset
8. Technicalspecications
9. Connection examples
page 3
page 3
page 4
page 4
page 4
page 5
page 6
page 6
page 7
page 7
page 7
page 7
page 8
page 8
page 9
page 10
page 11
page 11
page 11
page 11
page 12

3
1. Introduction
CM1000isaexiblekeypadandMifarereaderinoneunitformanydierentapplica-
tions.
In standby the yellow LED is lit LED ( )
Correct code/tag lights the yellow and the green LED ( )
Incorrect code/tag lights the red LED ( )
CM1000 has a buzzer for indicating while keying, correct code/tag, incorrect etc. and
2 transistor outputs, independant from each other, so the CM1000 can give access by
code and Mifare tag. The CM1000 is a stand alone unit that can be programmed
directly by Master code and Service code.
2. Installation
Mountthereaderonaevensurface.(usethefollowingdrilltemplateforpreciset-
ting).
Connect the wires to power supply, door strike, assembly board etc.
Colour scheme
Note: Right after applying the voltage all LED’s lights and the buzzer sounds do not
touch the reader untill the yellow LED lights and the buzzer is silent.
See connection examples on the last page.

3. Programming users
Programming the CM1000 is simple and easy to understand.
3.1 User positions
CM1000 has 200 positions, which can contain a code or a Mifare tag. The positions
are divided as following:
User position Function
1 - 100 Activates output 2 (the code in position 1 is 1234 - default)
101 - 150 Activates output 1
151 - 190 Activates output 1 and 2
191 - 200 Reserved for special functions
3.2 Programming user codes
The Master code is used to program/change/delete the users. By default the Master
code is 4711.
LED indication: No light: Light: Flash: ** Clearbuer:
New users
(4711 - standard)
To program more users, continue from “key in the user position” or press to
exit.
Changing user codes
It’s the same procedure as programming new users, just overwrite the user positions.
#
Key in the
Master code #
Key in the
user position #
Key in the
user code
#
4

5
Delete specic users
(4711 - standard)
Delete all users
(4711 - standard)
3.2 Programming Mifare tags
CM1000 can read Mifare classic 1K, classic 4K, Ultralight, Ultralight C, PLUS and DES-
FIRE.
Programming a new Mifare tag
(4711 - standard)
For more tags, continue from “key in the user position or type to exit.
Changing Mifare tags
It’s the same procedure as programming new users, just overwrite the position.
Delete a specic Mifare tag
(4711 - standard)
#
Key in the
Master code #
Key in the
user position ##
#
Key in the
Master code #
Key in
2500 #
#
Key in the
Master code #
Key in the
user position #
Show
Mifare tag
#
#
Key in the
Master code #
Key in the
user postion #
#

6
3.4 Programming codes/Mifare tags for special functions
Programming the codes and Mifare tags is described in 3.2 and 3.3. This entry acti-
vates the output(s) for 5 seconds (factory setting). Only 1 user can enter at the time.
Programming the same user twice
By programming the same code/Mifare tag on the same position twice toggles the
output.
(Ie. the code/Mifare tag is entered to unlock the door and entered to lock it again).
Programming the same user 3 times
By programming the same code/Mifare tag on the same position 3 times, the output is
designated as switch on only.
(Ie. the door is permanently unlocked when the code/Mifare tag is entered).
Programming the same user 4 times
By programming the same code/Mifare tag on the same position 4 times, the output is
designatedasswitchoonly.
(Ie. the door is only locked when the code/Mifare tag is entered).
3.5 Smart reading
This position makes it possible to program codes/Mifare tags quickier without enter-
ing new positions. Key in a position and it counts automatically to the next position.
CodesandMifaetagscanbeprogrammedalternativelyasyouseet.
**FFFFFF **FFFFFF For more
codes/tags
repeat from
here
Note: This programming mode overwrites existing positions.
#
Key in the
Master code #
Key in
05 #
Key in the start-
ing position #
Key in the code
or show tag

7
4.CongurationofCM1000
4.1 The Service code
The Service code is used for CM1000’s advanced settings such as changing the Master
code and Service code, LED indications and much more. The overview of the settings
and the factory settings can be seen in 4.2 Conguration overview.
The Service code is 12347890 (factory setting).
Note: Before the Service code can be used must the voltage be turned OFF and
ON (the Service code can now be entered within 10 seconds).
After entering the Service code the reader is in programming mode (the green LED
lights). Each time a setting is made the CM1000 goes back to the previous point and
the next setting can be made.
The navigation is by entering the position/ value followed by #.
4.2Congurationoverview
Position Setting Factory default
00 Master code (1 til 8 cifre) 4711
01 Service code (1 til 8 cifre) 12347890
02 LED indications Normal = Yellow, active = Yellow and green
03 Outputs Output time for 1 and 2 is 5 seconds
04 Special functions
05 Smart reading
06 Background light
08 Backup/cloning the settings
2500 Alle codes/Mifare tags on the user positions are deleted
0250 Reset to factory default
4.3 Change the Master code
By default the Master code is 4711 and can only be used to program, change or delete
users on the CM1000.
To change the Master code, enter the following:
#
Key in the
Service code #
Key in
00 #
Key in a new
code or show tag

4.4 Change the Service code
TheServicecodeisusedtoconguratetheCM1000’ssettings.
To change the Service code, enter the following within 10 seconds after power on:
****F
4.5 LED indications
The CM1000’s 3 LED’s can be adjusted at will.
To adjust the LED indications enter the following:
adjust the LED’s for standby indication (normal).
adjust the LED’s for correct code/tag indication (active).
adjust the keying indication (how the LED will react while keying).
To adjust the LED’s press on the following:
= yellow LED (toggle by press)
= green LED (toggle by press)
= red LED (toggle by press)
= buzzer (works only on active and keying indication (toggle by press))
= save and go one step back
To save the settings press or press / to go back to the previous
point (not saving).
#
Key in the
Service code #
Key in
01 #
Key in a new
code or show tag #
Repeat new
code/tag
#
02
#
1
#
2
#
3
1
2
3
0
#
8
******
******
******
******
#*

4.6 Outputs
The CM1000 has 2 transistor outputs, which both are activated for 5 seconds (factory
default) when a correct code/Mifare tag is entered. The output activation time can be
changed and inverted.
To change these settings key in:
acitvation time for output 1 (white core)
activation time for output 2 (yellow core)
The time is set as:
If no value is entered in hours, minutes or seconds is the value automatically 0 (which
corresonds to set the output as toggle).
bonding the positions and output 1
bonding the positions and output 2
Bothoutputsarebondedtospecicpositions.Byfactorydefaultpositions1to100are
bounded to output 2 and positions 101 to 150 to output 1.
The value can not be crossed.
inverted outputs
output 1 ( = inverted / = not inverted)
output 2 ( = inverted / = not inverted)
To save the settings press or press / to go back to the previous
point (not saving).
9
#
03
#
1
#
2
#
Key in hours
0 to 60 #
Key in minutes
0 to 60 #
Key in seconds
0 to 60
#
3
#
4
#
5
1
2
#*

4.7 Special settings
These settings is used to change the CM1000’s special functions such as turning the
buzzeron/o,enableHighSecurityetc.
To change these settings, key in:
= Service code without timeout ( = inactive / = active)
= Master code be changed by Master code ( = inactive / = active)
= Mute reader ( =o/ = on)
= Brown wire function ( = external buzzer / =HighSecurity)
=HighSecurity( = inactive / = active)
= Bell/star key ( =deletenon-nishedcodes/ = activates output 1*)
*When the bell/star key is set to activate output 1 can codes and Mifare tags only activate output 2.
High Security
HighSecurityincreasestheCM1000’ssecuritybyensuring2positionshavetobeacti-
vated before the output is activated (the positions must be next to each other).
Special positions
On positions 191 to 194 special functions can be activated by code/Mifare tag. The
programming is like programming a new user.
191 = No buzzer
192=Input1(brownwire)function(HighSecurityorexternalbuzzer)
193=HighSecurity
194 = Bell/star key function (activates output 2 by press)
To save the settings press or press / to go back to the previous
point (not saving).
Note: A power cucle puts the functions back to the settings made by the Service code.
10
#
04
1
2
3
4
5
6
#*

5. Backup card
The CM1000’s informations can be saved and loaded with a Backup card (Art. No.:
480080).
Pleaseviewthefollowingcongurationschemeforfurtherinformation.
6. Blocking
The CM1000 is blocked for 1 minute after 4 incorrect codes/Mifare tags.
LED indication: **
7. Manual reset
The CM1000 can be reset to factoty default manually.
•Turnthevoltageo.
• Connect the yellow and brown wire.
• Turn the voltage on (9 - 25 VDC) the readers LED’s lights and the buzzer sounds.
•Turnthevoltageoanddisconnecttheyellowandbrownwire.
The CM1000 is now reset to factory default and the user codes/tags are deleted.
8.Technicalspecications
Voltage: 12 VDC, 30 mA
Voltage range: 9 - 25 VDC
Mifare reading: Max. 50 mm
Output: 2x open collector, max. 500 mA
Input: Externalbuzzer/HighSecurity(brown)andREX,0Vactive(blue)
Protection rate: IP67
Color: Black or white
Cable: 2,5 m white, 8 cores
Dimensions(HxWxD): Mykey=76x49x8mm/Classic=130x50x8mm
11

9. Connection examples
Direct connection
Relay connection
Thank you for choosing Conlan’s products.
For further assistance please contact
our support service
This manual suits for next models
4
Table of contents
Other Conlan Keypad manuals
Popular Keypad manuals by other brands

Toshiba
Toshiba RKP004Z-0 instruction manual

resideo
resideo PROSIXLCDKP-EU Series Installation and setup guide

Storm AXS
Storm AXS S60 Series Engineering manual

ICT
ICT EliteSuite ELT-KLCS user manual

Door-Gard
Door-Gard Wiegand 272mp Programming and use instructions

Contro l4
Contro l4 C4-SKC installation guide

alphatronics
alphatronics AlphaVision ML installation instructions

CDVI
CDVI GALEO 4.0 - Bluetooth installation manual

Honeywell
Honeywell 6150 - Ademco Fixed - Display Keypad Installation and setup guide

Xantech
Xantech MRKP1E installation instructions

LOCKEY USA
LOCKEY USA PD2 installation instructions

DMP Electronics
DMP Electronics Thinline Series installation guide