Conlan CT1000 User manual

secure open
Conlan ApS • Speditorvej 2A • DK-9000 Aalborg • Tel: +45 72 40 60 03 • Fax: +45 96 32 00 22
www.conlan.eu • [email protected]
Keypad
CT1000
Art. No.: 460100 (black)
Art. No.: 460106 (white)
User Manual
CT1000_usermanual_ENGmay15

2
Table of Content
1. Introduction
2. Installation
3. Programming Users
3.1 Positions
3.2 Programming the User Codes
4. AdvancedCongurations
4.1 Service code
4.2 CongurationOverview
4.3 Changing the Master code
4.4 Changing the Service code
4.5 LED Indication
4.6 OutputTime
4.7 Function Settings
4.8 ActivatingtheOutputwithCode/Bellkey
5. Blocking(Duress)
6. Manuel Reset
7. TechnicalSpecications
page 3
page 3
page 4
page 4
page 4
page 5
page 5
page 5
page 6
page 6
page 6
page 6
page 7
page 7
page 8
page 8
page 8

3
1. Introduction
CT1000isaexiblekeypadformanydierentapplications.
In standby the yellow LED is lit (● ○ ○)
Correct code lights the yellow and the green LED (●● ○)
Incorrect code lights the red LED (○ ○ ●)
CT1000 has a buzzer for indicating while keying, correct code, incorrect etc. and 2 transistor
outputs with open collector for controlling of locks etc.
CT1000 is a stand alone unit, that can be programmed directly by Master Code and Service
Code.
2. Installation
• Mount the reader (use the drilling guide for proper alignment).
• Connectthewirestothepowersupply,lockunit,assemblyboxetc.
• Applyvoltage9VDC,max.25VDC.
Note: Right after applying the voltage all LED’s light and the buzzer sounds do not touch the
reader untill the yellow LED lights and the buzzer is silent.
9 - 25 VDC / 30 mA
0V GND
Output 2 open collector, 500 mA, 0V active
External controlling green LED, 0V active
Output 1 open collector 500 mA, 0V active
External buzzer
External controlling red LED, 0V active
REX, 0V active
1
3
5
7
9
2
4
6
8
0

3. Programming Users
3.1 Positions
CT1000 has 28 positions, which can contain a code from 1 to 8 digits.
The code in position 1 is 1234 (default)
3.2 Programming the User Codes
TheMasterCodeisusedtoprogram/change/deletetheusers.BydeafualttheMasterCodeis
4711.
LED indication: No light: ○Light: ●Flash: *Clearbuer:
New users
(4711 - standard) ○ ● ○ ●● ○ ●● ○ ○ ● ○
Toprogrammoreusers,continuefrom“Keyinthepositionortype toexit.
● ○ ○
Changing codes
It’s the same procedure as programming new users, just overwrite the positions.
Delete specic users
(4711 - standard) ○ ● ○ ●● ○ ○ ● ○ ● ○ ○
Delete all users
(4711 - standard) ○ ● ○ ○ ○ ● ○ ● ○ ● ○ ○
4
#
Key in the
Master Code #
Key in the
position #
Key in the user
code
#
#
Key in the
Master Code #
Key in the
position ##
#
Key in the
Master Code #
Key in
2500 #

5
4. Advanced settings
4.1 Service Code
The Service Code is used for CT1000’s advanced settings such as changing the Master Code
and Service Code, LED indication and much more. The overview of the settings and the facto-
ry settings can be seen in 4.2 Conguration Overview.
The Service Code is 12347890 (factory default).
Note:BeforetheServiceCodecanbeusedthevoltagemustbeturnedoandon(theSer-
vice Code can no.
After entering the Service Code the reader is in programming mode (the green LED lit).
Eachtimeasettingismade,theCT1000goesbacktothepreviouspointandthenextsetting
canbemade.Thenavigationisbyenteringthecongurationnumberand#
4.2CongurationOverview
Cong. no. Setting Default
00 Master Code (1 to 8 digits) 4711
01 Service Code (1 to 8 digits) 12347890
02 LED indication 31
03 Outputtime(white) 5
04 Outputtime(yellow) 5 (for codes)
05 Function settings 0
06 Activationwithcodes/bell 29
2500 All codes on position 1 to 28 is deleted
0250 Reset to factory default
4.3 Changing the Master Code
ByfactoryistheMasterCode4711 and can only be used to program, change or delete users
on the CT1000.
To change the Master Code, enter the following:
○ ● ○ ●● ○ ○ ● ○
#
Key in the
Service Code #
Key in
00 #
Key in a new
code

6
4.3 Changing the Service Code
TheServiceCodeisusedtocoguretheCT1000’ssettings.
To change the Service Code, enter the following:
○ ● ○ ●● ○ ** ○ ○ ● ○
4.5 LED Indication
CT1000’s 3 LED’s can be adjusted at will.
Putthedesiredvaluestogether(e.g.YELLOWasnormal,YELLOWandGREENasactive:
01+10+20 = 31) and key them in under “Key in value”.
Yellow LED Green LED Red LED
Normal 01 02 04
Active 10 20 40
To change the LED indication, enter the following:
○ ● ○ ●● ○ ○ ● ○
Afteryouhaveentered#thenextsettingcanbechanged,toleavetheprogrammingmode
enter # again or wait 10 seconds.
4.6OutputTime
CT1000 has 2 transistor outputs (yellow (04) and white (03) wire), which both are activivated in
5 seconds (factory default) by correct code, the activation time can be changed.
The values are divided like this: 1 - 100 in seconds (e.g. 5 = 5 seconds, 101 - 199 in minutes
(e.g. 105 = 5 minutes) and 0 is toggle.
To change these settings, enter the following:
○ ● ○ ●● ○ ○ ● ○
Afteryouhaveentered#thenextsettingcanbechanged,toleavetheprogrammingmode
enter # again or wait 10 seconds.
#
Key in the
Service Code #
Key in
01 #
Key in a new
code #
Repeat new
code
#
Key in the
Service Code #
Key in
02 #
Key in value
#
Key in the
Service Code #
Key in
03 / 04 #
Key in value

7
4.7 Function Settings
These settings is used to change CT1000’s function e.g. to use the Service Code without pow-
er down and up, mute the buzzer etc.
Theoverviewbelowshowsthevaluesforthedierentfunctions.
On O
Buzzer 0 1
Toggle mode for 8 digits codes 2 0
ServiceCodewithpoweron/o 4 0
Output(yellowwire)inverted 8 0
Hold function 16 0
Lock L2H 32 0
Lock H2L 64 0
4 digits code without # (rolling code) 128 0
Put the desired values together and enter them in “Key in value”.
To change the function settings, enter the following:
○ ● ○ ●● ○ ○ ● ○
4.8ActivatingtheOutputwithCodes/Bell
This function is by default set that all codes activate the yellow output and the bell key acti-
vates the white output (value = 29). If the white output also should activate by codes key in 1
to 27 as value, it is the position after the entered value that starts to activate the white out-
put.
To change theses settings, enter the following:
○ ● ○ ●● ○ ○ ● ○
It is the position after the entered value that starts to activate the white output.
#
Key in the
Service Code #
Key in
05 #
Key in value
#
Key in the
Service Code #
Key in
06 #
Key in value
1 to 27

5.Blocking(Duress)
The CT1000 is blocked for 1 minute after 4 incorrect codes.
Indication: ○○*
6. Manuel Reset
CT1000 can be reset to default settings manually.
Turnothevoltage,connecttheyellowandbrownwire,turnthepoweronagainandthe
readersLED’slightandthebuzzersounds.WhenonlytheyellowLEDislitandthereaderis
silent,turnothepowerandseparatetheyellowandbrownwire.
The CT1000 is now reset to default and the user codes are deleted.
7.TechnicalSpecications
Voltage: 12 VDC, 30 mA
Voltage interval: 9 - 25 VDC
Output(yellowcore): Max.500mA
Output(whitecode): Max.500mA
ExternalcontrollinggreenandredLED
Externalcontrollingbuzzer,HoldandLock
Protection rate: IP67
Color: Blackorwhite
Dimensions(HxWxD): 130x50x8mm
Thank you for using Conlan’s products.