manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Contro l4
  6. •
  7. Switch
  8. •
  9. Contro l4 C4-SW240 User manual

Contro l4 C4-SW240 User manual

™
Warnings and considerations
WARNING! Turn OFF electrical power before installing or servicing this
product. Improper use or installation can cause SERIOUS INJURY, DEATH
or LOSS/DAMAGE OF PROPERTY.
WARNING! This device must be protected by a circuit breaker (20A max).
WARNING! Ground this device in accordance with the National Electric
Code (NEC) requirements. DO NOT rely solely upon the yoke plate’s
contact with a metal back box for adequate grounding. Use the device’s
ground wire to make a secure connection to the safety ground of the
electrical system.
IMPORTANT! This device must be installed by a licensed electrician in
accordance with all national and local electrical codes.
IMPORTANT! If you are unsure about any part of these instructions,
consult a qualified electrician.
IMPORTANT! Use this device only with copper or copper-clad wire. Do
not use aluminum wiring. This product has not been approved for use with
aluminum wiring.
IMPORTANT! Using this product in a manner other than outlined in this
document voids your warranty. Further, Control4 is NOT liable for any
damage incurred with the misuse of this product. See “Troubleshooting.”
IMPORTANT! Do NOT use a power screwdriver to install this device. If you
do, you may overtighten the screws and strip them. Also, overtightening
the screws may interfere with proper button operation.
IMPORTANT! This is an electronic device with intricate components.
Handle and install with care!
IMPORTANT! When used in conjunction with an Auxiliary Keypad
(C4-KA-xx), the wire connecting the Auxiliary Keypad to the switch must
not exceed 30 m (100 ft.) at 240V AC.
Installation instructions
1 Ensure that the location and intended use meet the following criteria:
• Do not exceed the load capacity requirements of the switch. Refer to the
load ratings in the specifications above for details.
• Install in accordance with all national and local electrical codes.
• The range and performance of the wireless control system is highly
dependent on the following: (1) distance between devices; (2) layout
of the home; (3) walls separating devices; and (4) electrical equipment
located near devices.
2 Turn o the mains electrical power at the consumer unit. To ensure the wires
do NOT have power running to them, use an inductive voltage detector.
NOTE: The back box wiring shown in this document is an example. Your
wire colors and functions may dier. If you are not sure which wires are
the Line In/Hot, Neutral, Load, Traveler, and Earth Ground wires, have a
trained electrician perform the installation.
3 Prepare each wire. Wire insulation should be stripped back 7mm from the
wire end (see Figure 1).
Supported model
• C4-SW240 Switch. 240V
Introduction
The Control4® Switch operates independently or as part of a Control4 home
automation system. It installs in a standard back box using typical wiring standards
and communicates to the Control4 system using a wireless connection.
Box contents
• Switch
• Terminal block
• Warranty card
• Switch Installation Guide (this document)
Specifications and supported load types
The specifications are described below.
Model number C4-SW240-xx
Power requirements 220V AC-240V AC +/-10%, 50/60 Hz
This device requires a neutral connection. See
the “Sample Wiring Configurations” later in this
guide.
Power consumption 950mW
Load types and ratings
Supported load types Incandescent, halogen, electronic (solid
state) low voltage (ELV) transformers,
magnetic (iron core, inductive) low voltage
(MLV) transformers, fluorescents, compact
fluorescents, LEDs, motors
Maximum load 10A, 1/2HP
Environmental
Operational temperature 0 to 40 ˚C (32 to 104 ˚F)
Humidity 5% to 95% non-condensing
Storage -20 to 70 ˚C (-4 to 158 ˚F)
Miscellaneous
Control communications Zigbee, IEEE 802.15.4, 2.4 GHz, 15-channel
spread spectrum radio
Wallbox volume 94.2 cubic centimeters (5.75 cubic inches)
Weight 0.05 kg (0.12 lb.)
Shipping weight 0.08 kg (0.18 lb.)
Switch
Installation Guide
Figure 1. Strip wire insulation
4 Identify your wiring application, and then see the appropriate wiring diagram
in the “Sample Wiring Configurations” section below.
IMPORTANT! Not grounding this product, as described in the section
“Warnings and Considerations,” may result in an installation less immune
to damage caused by electrical disturbances, such as ESD or lightning,
and may void the warranty.
5 Identify and connect the switch wires to the back box wires using the
terminal block.
IMPORTANT! The yellow wire is not a traditional traveler. It cannot directly
power a lighting load. It must be used only to connect to a Control4
Auxiliary Keypad. See “Sample Wiring Configurations.”
TIP: If you are using a Control4 push-on (screwless) faceplate in a multi-
gang installation, attach the black faceplate sub-plate to all of the devices
that will be installed into the wallbox prior to attaching the devices to the
wallbox. This will help ensure that all the devices are properly aligned and
on the same plane after installation.
6 Fit the wires back into the back box. Bend the wires in a zigzag pattern so
that they easily fold into the back box.
7 Align the switch to the back box (the load rating label should be at the
bottom) and fasten it with screws. Tighten the screws until the back side of
the yoke plate is even with the wall surface, but no further. Overtightening can
warp the dimmer and cause mechanical malfunction.
8 Install the Control4 Faceplate following the instructions in the Faceplate
Installation Guide or attach a standard Decora-style faceplate.
9 Turn on mains power at the consumer unit.
Operation and configuration
On initial power up, all status LEDs on the switch will illuminate green indicating
that the device has power. To set up this switch for use with a Control4 system,
refer to the Composer Pro User Guide.
To operate this switch as a stand-alone device:
• Press the top button to turn the light on.
• Press the bottom button to turn the light o.
Button tap sequences
Function Button tap sequence
(either top button only, or top-bottom-top)
Identify 4
Zigbee channel 7
Reboot 15
Factory reset 9-4-9
Leave mesh and reset 13-4-13
Troubleshooting
If the light does not turn on:
• Ensure at least one LED on the face of the switch is lit.
• Ensure the light bulb is not burned out and is screwed in tightly.
• Ensure that the circuit breaker is not turned o or tripped.
• Check for proper wiring (see “Sample Wiring Configurations”).
Care and cleaning
• Do NOT paint the switch or its wall plate.
• Do NOT use any chemical cleaners to clean the switch.
• Clean surface of the switch with a soft damp cloth as needed.
Regulatory/safety information
To review regulatory information for your particular Control4 products, see the
information located on the Control4 website at
ctrl4.co/reg
.
Warranty
For complete warranty information, including details on consumer legal rights as
well as warranty exclusions, visit
ctrl4.co/warranty
.
Patent information
Applicable patents are available at
ctrl4.co/patents
™
Sample wiring configurations
Figure 2. Single device location
Figure 3. Multiple device location using Auxiliary Keypad
Figure 4. Multiple device location using Configurable Keypad
Auxiliary Keypad
Maximum length:
240V AC 30 m (100 ft.)
Copyright ©2021, Wirepath Home Systems, LLC. All rights reserved. Control4 and SnapAV and their respective logos are registered trademarks or trademarks of Wirepath Home Systems, LLC,
dba “Control4” and/or dba “SnapAV” in the United States and/or other countries. 4Store, 4Sight, Control4 My Home, Snap AV, Araknis Networks, BakPak, Binary, Dragonfly, Episode, Luma,
Mockupancy, Nearus, NEEO, Optiview, OvrC, Pakedge, Sense, Strong, Strong Evolve, Strong Versabox, SunBriteDS, SunBriteTV, Triad, Truvision, Visualint, WattBox, Wirepath, and Wirepath ONE are
also registered trademarks or trademarks of Wirepath Home Systems, LLC. Other names and brands may be claimed as the property of their respective owners. All specifications subject to change
without notice.
200-00354-E 210408MS

Other Contro l4 Switch manuals

Contro l4 C4-V-OSW120 User manual

Contro l4

Contro l4 C4-V-OSW120 User manual

Contro l4 C4-SW101-Z-W User manual

Contro l4

Contro l4 C4-SW101-Z-W User manual

Contro l4 LOZ-5S1-W User manual

Contro l4

Contro l4 LOZ-5S1-W User manual

Contro l4 LOZ-5S1-W User manual

Contro l4

Contro l4 LOZ-5S1-W User manual

Contro l4 LOZ-5S1-W User manual

Contro l4

Contro l4 LOZ-5S1-W User manual

Contro l4 C4-SDSW240-N User manual

Contro l4

Contro l4 C4-SDSW240-N User manual

Contro l4 LSZ-101-W User manual

Contro l4

Contro l4 LSZ-101-W User manual

Contro l4 C4-16S2-E-B Assembly instructions

Contro l4

Contro l4 C4-16S2-E-B Assembly instructions

Contro l4 C4-DIN-8ESW-E User manual

Contro l4

Contro l4 C4-DIN-8ESW-E User manual

Contro l4 LSZ-101 User manual

Contro l4

Contro l4 LSZ-101 User manual

Contro l4 C4-SSW240-N User manual

Contro l4

Contro l4 C4-SSW240-N User manual

Contro l4 C4-DIN-8RELSW-E User manual

Contro l4

Contro l4 C4-DIN-8RELSW-E User manual

Contro l4 C4-SW120277 Series User manual

Contro l4

Contro l4 C4-SW120277 Series User manual

Contro l4 C4-SW240 Series User manual

Contro l4

Contro l4 C4-SW240 Series User manual

Contro l4 LOZ-5S1-W User manual

Contro l4

Contro l4 LOZ-5S1-W User manual

Contro l4 C4-SW1-Z User manual

Contro l4

Contro l4 C4-SW1-Z User manual

Contro l4 C4-SW120277 Series User manual

Contro l4

Contro l4 C4-SW120277 Series User manual

Contro l4 C4-SW1-Z User manual

Contro l4

Contro l4 C4-SW1-Z User manual

Contro l4 LSZ-102-W User manual

Contro l4

Contro l4 LSZ-102-W User manual

Contro l4 AVM-16S1-B User manual

Contro l4

Contro l4 AVM-16S1-B User manual

Contro l4 AVM-16S1-B Operating manual

Contro l4

Contro l4 AVM-16S1-B Operating manual

Popular Switch manuals by other brands

Intellinet 561877 instructions

Intellinet

Intellinet 561877 instructions

Cisco Catalyst 3120G Quickspecs

Cisco

Cisco Catalyst 3120G Quickspecs

D-Box HaptiSync Hub quick start guide

D-Box

D-Box HaptiSync Hub quick start guide

Edimax ED-1508 user manual

Edimax

Edimax ED-1508 user manual

Juniper EX2300-C Hardware guide

Juniper

Juniper EX2300-C Hardware guide

Raritan MCC4 user manual

Raritan

Raritan MCC4 user manual

EuroLite LVH-7 user manual

EuroLite

EuroLite LVH-7 user manual

Belkin OmniView SOHO F1DS102L user manual

Belkin

Belkin OmniView SOHO F1DS102L user manual

Broadata Link Bridge LBC-PSW52 user manual

Broadata

Broadata Link Bridge LBC-PSW52 user manual

Dell PowerConnect 6224 release note

Dell

Dell PowerConnect 6224 release note

Intermatic T7802B supplementary guide

Intermatic

Intermatic T7802B supplementary guide

Kärcher 6.997 Series manual

Kärcher

Kärcher 6.997 Series manual

Cisco Nexus 7718 Hardware installation guide

Cisco

Cisco Nexus 7718 Hardware installation guide

Hawking HKS104 Quick installation guide

Hawking

Hawking HKS104 Quick installation guide

ATEN VP2120 user manual

ATEN

ATEN VP2120 user manual

Kathrein EXD 158 Twin manual

Kathrein

Kathrein EXD 158 Twin manual

TJERNLUND SIDESHOT SS1C INCREASED CAPACITY OIL VENT SYSTEM... installation instructions

TJERNLUND

TJERNLUND SIDESHOT SS1C INCREASED CAPACITY OIL VENT SYSTEM... installation instructions

AV Access 4KMX42-H2A user manual

AV Access

AV Access 4KMX42-H2A user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.