6.2 Cooling operation
- Press the “MODE” button till the “Cool” icon appears.
- Press the “ DOWN ”or“ UP ”button to select a desired room temperature.
(61°F-88°F)
- Press the “ SPEED ” button to select wind speed.
6.3 Dehumidifying operation
Press the “MODE” button till the “Dehumidify” icon appears .
- Automatically set the selected temperature to current room temperature minus 2°F.
(61°F-88°F)
- Automatically set the fan motor to LOW wind speed.
6.4 Fan operation
- Press the “MODE” button till the “Fan” icon appears.
- Press the “ SPEED ” button to select wind speed.
6.5 Timer operation
Timer ON setting:
- When the air-conditioner is OFF, press the “TIMER” button and select a desired
ON time through the temperature and time setting buttons.
- “Preset ON Time” is displayed on the operation panel.
- ON time can be regulated at any time in 0-24 hours.
Timer OFF setting
- When the air-conditioner ON, press “TIMER” button and select a desired OFF
time through the temperature and time setting buttons.
- “Preset OFF Time” is displayed on the operation panel.
- OFF time can be regulated at any time in 0-24 hours.
6.7 Auto SWING
After machine turns on, press this key, the louver will swing continuously left and
right; by pressing this button again the movement will stop and the louver remain in
that position.
6.8 SLEEP mode
- While in cooling mode, press the SLEEP key to set the temperature. It increases
1°F after an hour and at most increases 2°F after 2 hours.
- Press the SLEEP key again can cancel the setting.
6.9 Water drainage
Water Full Alarm
The inner water tray inside the air-conditioner has one water level safety switch, it
controls water level. When water level reaches an anticipated height, the water full
indicator lamp lights up. (If water pump is damaged, when the water is full, please
remove the rubber stopper at the bottom of unit, and all water will drain outside.)
Continuous Drainage
- When you plan to leave this unit unused for a long time, please remove the rubber
stopper from the drainage hole at the bottom of unit, and connect a drain hose to the
lower fixing clip. All the water in the water tank will drain outside.
- If water pump is damaged, continuous drainage can be used, and under this
condition, the water pump is not activated. The unit can also work well.
If water pump is damaged, intermittent drainage can also be used. Under this
condition, when the water full indicator lamp lights up, please connect a drain hose
to the lower fixing clip, then all the water in the water tray will be drained outside.
The unit can also work well.