Operating and Installation
Instructions
RoHS compliant. SO/PICCOLO/G3 Issue 05
Technical
Nominal Voltage: 12 volts DC
Voltage range: 9-15 volts DC
Sounder Type: Tone (Piezo)
Sound output level : 112 dB (A) @ 1 metre
Sound only Current: 84mA @ 12volts dc
Sound duration: Determined by control panel.
Flash only current: 17mA @ 12volts dc
Sound and ash: 100mA @ 12volts dc
System Status Current: 4mA @ 12volts dc
Temperature Range: -15° C to +40° C
Tamper Detection
Lid and mounting surface removal.
Housing
Base Material: Polycarbonate
Lid Material: ABS
Dimension (mm): 125mm x 85mm x 37.5mm
Specications
SO/PICCOLO/**/G3/S5
12 volt Internal Sounder
** denotes lens and lid colour
Low profile design.
112dB sound output.
Selectable alternating or continuous tone.
Flashing alarm indication.
System status indicator
Low current consumption.
Tamper protected lid and mounting.
Tamper
CFS
Tamper
Linked Sound & Flash
Tamper
CFS
Tamper
Flash only
Tamper
CFS
Tamper
Sound only
Tamper
CFS
Tamper
Independent Sound & Flash
-ve -ve
+ve
+ve
Not Connected
Not Connected
-ve
+ve
+ve sound
+ve ash
-ve common
Link
S = Sound +ve
F = Flashing LED’s +ve
C = Common -ve
Tamper x 2 = Lid and mounting surface tamper.
System status indication x 2
Connection Examples
FIRE & SECURITY
-ve supply
+ve supply
System status indication. (Permanently illuminates LED’s at lower intensity.)
EN50131-1:2006 + A1:2009
:Security Grade 3 Environmental Class II
EN50131-4:2009
Warning device type : Internal Remotely Powered
Safety Precautions
Always observe local regulations when disposing of this unit
Plastic bags can suocate, always dispose of packaging carefully
This remotely powered internal sounder can be installed in security systems up to and
including Grade 3 Environmental class II in accordance with EN50131:2006 + A1:2009. It is
certied by Telecation to EN50131-4:2009. The warning device gives an audible and visual
signal of alarm activation. The LED’s can also be wired independantly to indicate the system
status. The sound output is selectable for either alternating or continuous tone. It is also
protected against tampering by means of lid removal and removal from the mounting
surface.