Creatix CTX712 User manual

Creatix WLAN Modem Combo
CTX712 V.2
User Manual

This handbook is protected by copyright. It must not be copied, reproduced,
translated or transmitted in electronic media, in whole or in part.
Accuracy of the information is not guaranteed.
Any mention in this handbook of products of other manufacturers is for
information purposes only and represents no misuse of trademarks.
Safety instructions for Data-Fax-Modem
This equipment has been designed and tested in accordance with the
requirements of Standard IEC 950 „Safety of Information Technology
Equipment, Including Electrical Business Equipment“ Extracts from these
requirements according Standard IEC 950:
•The FAX-Modem was evaluated for use in maximum ambient temperature
of 40 °C.
•The FAX-Modem may only be used in countries where the modem is
certified.
•Neither the data transmission cable nor the telephone cable should be
connected or disconnected during a thunderstorm.
mv205a0.402uk

Regulatory Statements
FCC Certification
The United States Federal Communication Commission and the Canadian
Department of Communication have established certain rules governing the
use of electronic equipment.
Part15, Class B
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device my not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation. This equipment has been tested and
found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for
help.
Caution:
1. This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated
with minimum distance 20cm between the radiator and your body.
2. This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
3. Changes or modifications made to this equipment not expressly approved
by Creatix Polymedia GmbH may void the FCC authorization to operate this
equipment

Table of Contents
Chapter 0 INSTALLATION WLAN
Chapter 1 INTRODUCTION ................................ 1-1
What is a Modem? ...................................................................................... 1-1
About this Modem ....................................................................................... 1-1
The 56K Technology....................................................................................1-2
General Description .................................................................................... 1-2
Auto-Answering............................................................................................1-3
Installation Instructions Windows 95/98 ..............................................1-3
Windows 9x and ME......................................1-3
Windows NT 4.0 ............................................ 1-4
Windows 2000/XP .........................................1-4
Factory Settings .......................................................................................... 1-4
Chapter 2 AT COMMANDS: DATA MODEM ...... 2-1
Guidelines for Using AT Commands .......................................................... 2-1
AT - Attention Code .................................................................................... 2-3
The ESC Sequence .................................................................................... .2-3
A - Answer Mode .........................................................................................2-4
A/ - Repeat Last Command Line ................................................................ 2-4
B - BELL/CCITT ..........................................................................................2-4
D - Automatic Dialing and Dialing Parameters ............................................2-5
E – Echo Function ......................................................................................2-6
H – Switch Hook Check (Replace Handset) – Go "On Hook" ....................2-6
I – Firmware Information..............................................................................2-6
L – Volume Level ........................................................................................ .2-6
M – Switching the Loudspeaker On and .....................................................2-6
N – Recognizing Type of Modulation...........................................................2-7
O – Return to online Operation....................................................................2-7
Q – Modem Messages On / Off .................................................................. 2-7
S – Reading and Modifying Registers ........................................................2-7
V – Verbal or Numeric Modem Messages ..................................................2-7
W – Controlling Connect Messages ........................................................... 2-8
X – Result Code Type/Call Progress ..........................................................2-9
Y – Long Space Disconnect .......................................................................2-9
Z – Reset Modem/Record Stored Profile ....................................................2-9
&C – DCD (Data Carrier Detect) Option......................................................2-9

&D – DTR (Data Terminal Ready) Option ................................................2-10
&F – Loading the Factory Settings ...........................................................2-10
&G – Guard Tone .....................................................................................2-11
&K – Select Serial Port Flow Control ........................................................2-11
&S – DSR (Data Set Ready) ..................................................................... 2-11
&T – Data Mode Self-Test Command .......................................................2-11
&V – View Active Configuration and Stored Profiles ................................2-12
&W – Storing a set Profile .........................................................................2-12
&Y – Selecting a Start Configuration .........................................................2-12
&Z – Telephone Number Storage..............................................................2-13
+MS – Select Modulation. .........................................................................2-13
\A – MNP Block Size ................................................................................. 2-16
\B – Sending a Break Signal......................................................................2-16
\C – Set Auto-Reliable Buffer .................................................................... 2-16
\G – Set Modem Port Flow Check ............................................................2-16
\J – bps Rate Adjust Control. ....................................................................2-17
\K – Set Break Control ..............................................................................2-17
\N – Set Operating Mode .......................................................................... 2-18
\Q – Set Serial Port Flow Control...............................................................2-18
\T – Set Inactivity Timer .............................................................................2-19
\X – Set XON/XOFF-Pass Through........................................................... 2-19
-J – Set V.42 Detect Phase ......................................................................2-19
%C – MNP5 Data Compression Control ...................................................2-19
%E – Auto-Retrain Control .......................................................................2-20
%G – Rate Renegotiations ........................................................................2-20
"H – V.42bis Compression Control ...........................................................2-20
"O – V.42bis String Length ....................................................................... 2-20
Chapter 3 MODEM MESSAGES ........................ 3-1
Chapter 4 S-REGISTERS ................................... 4-1
S0 – Number of Ring Characters before Modem engages ........................ .4-2
S1 – Ring Character Counter .....................................................................4-2
S2 – Esc Sequence Character ................................................................... .4-2
S3 – Carriage Return Character ................................................................. 4-2
S4 – Line Feed Character............................................................................4-2
S5 – Backspace Character .........................................................................4-2
S6 – Waiting Time for Dial Tone .................................................................4-3
S7 – Waiting for Carrier Signal ................................................................... 4-3
S8 – Pause Time after Comma ...................................................................4-3

S9 – Answer Time after Carrier Recognition 4-3
S10 – Delay between Carrier Loss and Hanging Up...................................4-3
S12 – Guard Time for Esc Sequence .........................................................4-4
S14 – General Options ................................................................................4-4
S16 – Modem Test Options ........................................................................ .4-5
S18 – Test Timer ........................................................................................4-5
S21 – V.24/General Options........................................................................4-5
S22 – Loudspeaker/Authorized Modem Messages .................................... 4-6
S23 – General Options ............................................................................... 4-6
S25 – DTR Delay Time ............................................................................... 4-7
S27 – General Options ............................................................................... 4-7
S30 – Inactivity Timer ..................................................................................4-7
S33 – Sleep Modem Timer .........................................................................4-8
S37 – Maximum Line Speed Attempted .....................................................4-8
TECHNICAL INFORMATION.................................. A-1
GLOSSARY ................................................................................................A-1
CCITT RECOMMENDATIONS ...................................................................A-2
Technical Specifications ..............................................................................A-3
Support ........................................................................................................A-4
COUNTRY CODE CONVERSION
when using new drivers
Drivers concerned: W2K/XP drivers

CHAPTER 0 INSTALLATION WLAN



Table of contents
Other Creatix Modem manuals






















