DO GUIDE
DM-PSU-16 Rear Panel Connections
NOTE: Ensure that the device is properly grounded by connecting the chassis ground lug to an
earth ground (building steel).
NOTE: The eight POWER ports of the DM-PSU-8 and the sixteen POWER ports of the
DM-PSU-16 are PoDM and HDBaseT®PoE PSE (Power Sourcing Equipment) ports. Any wiring that is
connected to a PoDM or HDBaseT PoE port is for intrabuilding use only and should not be connected
to a line that runs outside of the building in which the PSE is located.
DM-PSU-8/DM-PSU-16
8-Port/16-Port PoDM Power Supply for DM 8G+®I/O Cards
DO Install the Device
The Crestron®DM-PSU-8 and DM-PSU-16 can be mounted into a rack or placed onto a at surface.
Mounting into a Rack
Each device occupies 1U of rack space. Using a #1 or #2 Phillips screwdriver, attach the two
included rack ears to the device. Then, mount the device into the rack using four mounting screws
(not included).
Placing onto a Flat Surface
When placing the device onto a at surface or stacking it with other equipment, attach the included
feet near the corners on the underside of the device.
DO Connect the Device
Connect the device as required for the application.
DM-PSU-8 Rear Panel Connections
DO Check the Box
QTY PRODUCT COLOR PART NUM.
2Bracket, Rack Ear, 1U 2032122
4 Foot, 0.5" x 0.5" x 0.23", Adhesive Black 2002389
1 Power Cord, 6' 7" (2 m) 4505164
POWER
MAX 15.4 W/PORT 1–8:
To POE IN port of DM 8G®I/O card
or to HDBaseT
®
device
100–240 V ~50/60 Hz
2.2–1.0 A:
Mains power input
Ground
POWER
MAX 15.4 W/PORT 1–16:
To POE IN port of DM 8G I/O card
or to HDBaseT device
100–240 V ~50/60 Hz
3.5–1.6 A:
Mains power input
Ground
DO GUIDE DOC. 7970A (2048244) 04.17
Specications subject to change without notice.
DO Learn More
Visit the website for additional information and the latest rmware
updates. To learn more about this product, use a QR reader
application on your mobile device to scan the QR image.
Crestron Electronics
15 Volvo Drive, Rockleigh, NJ 07647
888.CRESTRON | www.crestron.com
As of the date of manufacture, the product has been tested and found to comply with specications for CE marking.
These products are Listed to applicable UL®Standards and requirements by Underwriters Laboratories Inc.
Ces produits sont énumérés aux normes applicables et les exigences UL par Underwriters Laboratories Inc.
Federal Communications Commission (FCC) Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
CAUTION:Changes or modications not expressly approved by the manufacturer responsible for compliance could void the
user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Industry Canada (IC) Compliance Statement
CAN ICES-3(B)/NMB-3(B)
Rack Mounting Safety Precautions
•Elevated Operating Ambient Temperature: If installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than room ambient temperature. Therefore, consideration should be
given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specied by the
manufacturer.
•Reduced Airow: Installation of the equipment in a rack should be such that the amount of airow required for safe operation
of the equipment is not compromised.
•Mechanical Loading: Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due
to uneven mechanical loading.
•Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the
effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
•Reliable Earthing: Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given
to supply connections other than direct connections to the branch circuit (e.g., use of power strips).
The specic patents that cover Crestron products are listed at http://www.crestron.com/legal/patents. The product warranty can be found at www.crestron.com/warranty.
Certain Crestron products contain open source software. For specic information, please visit www.crestron.com/opensource.
Crestron, the Crestron logo, DM 8G, and DM 8G+ are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. HDBaseT is either
a trademark or registered trademark of the HDBaseT Alliance in the United States and/or other countries. UL and the UL logo are either trademarks or registered trademarks of Underwriters
Laboratories, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming
the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography.
This document was written by the Technical Publications department at Crestron.
©2017 Crestron Electronics, Inc.
DM-PSU-8 DM-PSU-16

This manual suits for next models

1

Other Crestron Power Supply manuals

Crestron CSA-PWS300-CAEN User manual

Crestron

Crestron CSA-PWS300-CAEN User manual

Crestron ST-PC User manual

Crestron

Crestron ST-PC User manual

Crestron CSA-PWS10S-HUB User manual

Crestron

Crestron CSA-PWS10S-HUB User manual

Crestron C2N-SPWS300 User manual

Crestron

Crestron C2N-SPWS300 User manual

Crestron CSA-PWS10S-HUB User manual

Crestron

Crestron CSA-PWS10S-HUB User manual

Crestron DigitalMedia DM-MDA-64-PWS User manual

Crestron

Crestron DigitalMedia DM-MDA-64-PWS User manual

Crestron GLA-PWSI50 User manual

Crestron

Crestron GLA-PWSI50 User manual

Crestron FT2A-UTK-PWS User manual

Crestron

Crestron FT2A-UTK-PWS User manual

Crestron CSA-PWS10S-HUB-ENET User manual

Crestron

Crestron CSA-PWS10S-HUB-ENET User manual

Crestron DM-PSU-ULTRA-MIDSPAN User manual

Crestron

Crestron DM-PSU-ULTRA-MIDSPAN User manual

Crestron CSA-PWS225 How to use

Crestron

Crestron CSA-PWS225 How to use

Crestron DM-PSUA-PWS User manual

Crestron

Crestron DM-PSUA-PWS User manual

Crestron GREEN LIGHT Power Switching User manual

Crestron

Crestron GREEN LIGHT Power Switching User manual

Crestron Green Light DIN-PWS50 How to use

Crestron

Crestron Green Light DIN-PWS50 How to use

Crestron DM-PSU-8-PLUS Dimensional drawing

Crestron

Crestron DM-PSU-8-PLUS Dimensional drawing

Crestron CNPWS-75 User manual

Crestron

Crestron CNPWS-75 User manual

Crestron GLA-PWS50 User manual

Crestron

Crestron GLA-PWS50 User manual

Crestron C2N-SPWS300 User manual

Crestron

Crestron C2N-SPWS300 User manual

Popular Power Supply manuals by other brands

VOLTCRAFT SPS12-60W operating instructions

VOLTCRAFT

VOLTCRAFT SPS12-60W operating instructions

National Instruments RMX-400 Series Programming manual

National Instruments

National Instruments RMX-400 Series Programming manual

IBM Power System AC922 Quick install guide

IBM

IBM Power System AC922 Quick install guide

Busch-Jaeger 6191/11-101 manual

Busch-Jaeger

Busch-Jaeger 6191/11-101 manual

Ameresco Solar SK Series Installation and operation manual

Ameresco Solar

Ameresco Solar SK Series Installation and operation manual

Monster Power HDP 2400 owner's manual

Monster Power

Monster Power HDP 2400 owner's manual

cytiva EPS 3501 XL operating instructions

cytiva

cytiva EPS 3501 XL operating instructions

Powerware 5075 kVA Installation & operation manual

Powerware

Powerware 5075 kVA Installation & operation manual

Furman elite AR-15 owner's manual

Furman

Furman elite AR-15 owner's manual

Aiphone IS-PU-S PRECAUTION & MOUNTING INSTRUCTION SHEET

Aiphone

Aiphone IS-PU-S PRECAUTION & MOUNTING INSTRUCTION SHEET

Matsusada DOEF Series instruction manual

Matsusada

Matsusada DOEF Series instruction manual

Pepperl+Fuchs HiD2024 manual

Pepperl+Fuchs

Pepperl+Fuchs HiD2024 manual

Pulsar PS402415 manual

Pulsar

Pulsar PS402415 manual

Puls ML100.100 installation manual

Puls

Puls ML100.100 installation manual

Good Will Instrument PSM-3004 user manual

Good Will Instrument

Good Will Instrument PSM-3004 user manual

Agilent Technologies Series N6700 user guide

Agilent Technologies

Agilent Technologies Series N6700 user guide

Rockwell Automation Allen-Bradley PowerFlex SCR user manual

Rockwell Automation

Rockwell Automation Allen-Bradley PowerFlex SCR user manual

Lake Shore Cryotronics 121 user manual

Lake Shore Cryotronics

Lake Shore Cryotronics 121 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.