manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Crowcon
  6. •
  7. Measuring Instrument
  8. •
  9. Crowcon APM 145 User manual

Crowcon APM 145 User manual

APM 145
PRESSURE
METER
OPERATING
INSTRUCTIONS
Crowcon Detection Instruments
172 Brook Drive,
Milton Park,
Abingdon,
Oxfordshire OX14 4SD
Tel: 01235 557780
email: sales@crowcon.com
web: www.antonbycrowcon.com
INSTRUMENT OPERATION
ON / OFF
Press and hold button for 0.5s to turn on.
Press and hold button for 2s to turn off.
Default switch-off interval is 5 minutes, unless any
button is activated or the pressure level is above 1
mbar.
MENU STRUCTURE
Main Menu
Test Menu
Let-by / Tightness
Pressure
Diff Pressure
Working Pressure
Operating Pressure
Flue Draught Pressure
Units of Measurement
Settings
Auto off timeout
Back light
Key click
Report
Supervisor settings
Set date & time
Edit owner line 1
Edit owner line 2
Change Password
Stored Logs
Select a log
Find a log by number
Delete all logs
Test Menu –Let-by / Tightness
Used to perform let-by, stabilisation and tightness test.
Durations, pass & fail controlled by user.
Data can be stored & shared.
Test Menu –Pressure
Used for quick timed pressure tests that do not need
to be stored & shared.
1. Positive pressure input spigot
2. Negative pressure input spigot
3. Backlit LCD screen
4. Multi-function 1 button
5. Multi-function 2 button
6. Multi-function 3 button
7. Power / Enter button
8. Escape / Cancel button
9. Infra-red LED
10. Magnet
11. Tilt stand / hook
STANDARD ACCESSORIES
The APM 145 is supplied complete with:
•Three AA Alkaline batteries
•Operating instructions
•Protective rubber boot with stand, hook
and magnet
INSTRUMENT APPLICATION
This instrument is not suitable for use with corrosive
substances or cyclic hydrocarbons, e.g. motor oil,
transmission fluid and Freon. To use the APM 145
with these components, isolation must be provided in
the form of a buffer, such as a mineral oil or dry air.
Test Menu –Diff Pressure
Used for differential pressure measurement where
both pressure spigots are used and the pressure
difference is shown on screen.
Test Menu –Working Pressure
Used to determine correct working pressure is set up
for appliances.
Data can be stored & shared.
Test Menu –Operating Pressure
Used to determine correct operating pressure is set up
for appliances.
Data can be stored & shared.
Test Menu –Flue Draught Pressure
Used to determine correct flue draught pressure.
Data can be stored & shared.
Units of Measurement
Select this menu option to change the pressure units
displayed on the meter.
Settings Menu –Auto off timeout
Changes the period when the unit will switch off if
unattended.
Settings Menu –Backlight
Changes the brightness of the backlight.
Lower settings will prolong battery life.
Settings Menu –Key Click
Enable/disable button click.
Settings Menu –Report
Change report sending option (printer, wireless or
toggle).
Settings Menu –Supervisor Settings
User configurable settings. Allows setting of time and
date, owner/company name and user password.
Stored Logs Menu
Search and retrieve stored logs. Allows log to be
reviewed, re-printed or re-transmitted over the
wireless link.
BATTERY REPLACEMENT
1. Remove the protective rubber boot by slipping it
away from the bottom of the case and sliding it over
the pressure spigots exposing the case back.
2. Remove the battery cover from the bottom of the
case by removing the four screws.
3. Remove the three AA batteries and replace with
good quality AA Alkaline batteries taking care to
install them the right way round.
4. Replace the battery cover carefully making sure it is
alligned properly and replace the screws. Take care
not to over tighten the screws otherwise it may
damage the case.
For best results and longer life always use quality
alkaline batteries MN1500 or equivalent.
CAUTIONS
Exposure to silicone based products, corrosive gases,
water / condensation and freezing should be avoided
at all times as this will cause damage to the sensor
and internal component corrosion.
This instrument should not be stored or operated
outside of its operating temperature range.
Particular care must be taken not to exceed the
maximum pressure ratings for the device as this
may rupture the sensor membrane. This is not
covered by the manufacturer’s warranty.
NOTE: The differential/gauge instruments will only
measure positive pressures i.e. positive pressure
applied to positive port, or negative pressure applied
to the negative port.
WARRANTY
This instrument is guaranteed against defects of
workmanship and materials for a period of twelve
months from date of invoice.
During the warranty period a defective instrument will
be repaired or replaced at the discretion of the
manufacturer. This warranty does not cover damage
or failure due to misuse or accident. Modification,
adjustment or any alteration shall void the warranty.
For any warranty claims to be considered the
instrument must be returned to Anton along with proof
of purchase at the sender’s cost.
FCC Compliance
NOTE: This equipment has been tested and found to
comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference when the equipment is operated
in a commercial environment. This equipment
generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance
with the instruction manual, may cause harmful
interference to radio communications. Operation of
this equipment in a residential area is likely to cause
harmful interference in which case the user will be
required to correct the interference at his own
expense.
SPECIFICATIONS
Power Supply
3 x AA Alkaline Batteries
Battery Life
> 20 hours*
Duty Cycle
Continuous.
Auto switch off after 5 mins.
Operating
Temperature
-10 to +50 °C
Weight
395 grams including
batteries
Dimensions
185 x 75 x 43 mm
Accuracy
±2% of reading
* Using recommended Industrial batteries
Units
APM 145
mbar
-39.99 to +19.99
+20.0 to +130.0
PSI
-0.29 to +1.89
mmHg
-15.00 to +19.99
+20.0 to +98.1
mmH2O
-199.9 to +199.9
+200 to +1336
inH2O
-8.03 to +52.63
hPa
-39.99 to +19.99
+20.0 to +130.0
Pa
-400 to 9999
kPa
-1.99 to 13.00

Other Crowcon Measuring Instrument manuals

Crowcon Sprint Pro 1 User manual

Crowcon

Crowcon Sprint Pro 1 User manual

Crowcon M07630 User manual

Crowcon

Crowcon M07630 User manual

Crowcon Tetra 3 User manual

Crowcon

Crowcon Tetra 3 User manual

Crowcon Gas-Pro User manual

Crowcon

Crowcon Gas-Pro User manual

Crowcon Gas-Tec User manual

Crowcon

Crowcon Gas-Tec User manual

Crowcon CellarSafe User manual

Crowcon

Crowcon CellarSafe User manual

Crowcon APM 135 User manual

Crowcon

Crowcon APM 135 User manual

Crowcon Tetra User manual

Crowcon

Crowcon Tetra User manual

Crowcon Triple Plus+ User manual

Crowcon

Crowcon Triple Plus+ User manual

Crowcon APM 155 User manual

Crowcon

Crowcon APM 155 User manual

Crowcon Gas-Pro User manual

Crowcon

Crowcon Gas-Pro User manual

Crowcon Clip User manual

Crowcon

Crowcon Clip User manual

Crowcon SprintPro 3 User manual

Crowcon

Crowcon SprintPro 3 User manual

Crowcon Gasman User manual

Crowcon

Crowcon Gasman User manual

Crowcon Gas-Pro User manual

Crowcon

Crowcon Gas-Pro User manual

Crowcon Xgard ESU C01987 Manual

Crowcon

Crowcon Xgard ESU C01987 Manual

Popular Measuring Instrument manuals by other brands

Vega VEGABAR 52 operating instructions

Vega

Vega VEGABAR 52 operating instructions

Extech Instruments AN200 user manual

Extech Instruments

Extech Instruments AN200 user manual

Wohler WA 335 operating manual

Wohler

Wohler WA 335 operating manual

Larson Davis NoiseTutor user manual

Larson Davis

Larson Davis NoiseTutor user manual

S+S Regeltechnik THERMASGARD ALTM2-Q Operating Instructions, Mounting & Installation

S+S Regeltechnik

S+S Regeltechnik THERMASGARD ALTM2-Q Operating Instructions, Mounting & Installation

Procentec ATLAS user manual

Procentec

Procentec ATLAS user manual

A&D AD-4531B instruction manual

A&D

A&D AD-4531B instruction manual

jacarta SP8 user manual

jacarta

jacarta SP8 user manual

Droplet SP2 manual

Droplet

Droplet SP2 manual

FLIR EXTECH SDL310 user guide

FLIR

FLIR EXTECH SDL310 user guide

TempSen ITAG4 BIO quick guide

TempSen

TempSen ITAG4 BIO quick guide

Dräger JM-105 Instructions for use

Dräger

Dräger JM-105 Instructions for use

Helios CO2 AP-A Installation and operating instructions

Helios

Helios CO2 AP-A Installation and operating instructions

Teledyne Lecroy PP006D Operator's manual

Teledyne Lecroy

Teledyne Lecroy PP006D Operator's manual

PCB Piezotronics 3711F112G Installation and operating manual

PCB Piezotronics

PCB Piezotronics 3711F112G Installation and operating manual

Burkert 8026 quick start

Burkert

Burkert 8026 quick start

Hytek HO Series Technical data

Hytek

Hytek HO Series Technical data

ANALOX O2EII Pro quick start guide

ANALOX

ANALOX O2EII Pro quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.