Crown IQ-PIP-USP3 User manual

IQ-PIP-USP3
ULTRA SERIES
Network Connector
The network connector is a standard RJ-45 con-
nector that allows the IQ-PIP-USP3 to connect to
an Ethernet network. Connection is made using a
standard CAT 5 cable to a network switch port.
In cases where an IQ-PIP-USP3 is used in stand-
alone mode (not connected to an network) it
can be configured using a crossover cable (TX
and RX pairs swapped) directly to a computer’s
network adapter port.
Indicators:
Preset Indicator
Signals the number of the current preset, if
active, by flashing a series of flashes equal to the
current preset number.
IQ Data Indicator
Flashes when the IQ-PIP-USP3 receives a valid
command that is addressed to the IQ-PIP-USP3.
Switches:
Reset/Preset Switch
Used to change presets, restore settings to
factory default or restore all the presets to the
factory defaults. During operations of the switch,
the Data indicator flashes as an aid to the user.
Memory Backup: 512 kbyte non-volatile FLASH
memory for backup of run-time parameters, pre-
sets, and program storage. Capable of greater
than 10 year data retention and estimated 20+
year life-cycle.
Communications: 100Mb Fast Ethernet conform-
ing to IEEE 802.3.
Power Requirements: +24VDC @ 250mA,
–24VDC @ 30mA. < 7 watts.
Overall Audio Performance:
DSP Processing: 32 bit, Floating Point,
665 µs latency.
Maximum Input Level: + 20 dBu.
ADC Conversion: 24 bit, 250 µs latency.
DAC Conversion: 24 bit, 135 µs latency.
Dynamic Range: >105 dB (A-weighted,
20Hz–20kHz).
Distortion: < 0.05% THD+N, 20Hz–20kHz.
Crosstalk: > 60 dB @ 1kHz.
Common Mode Rejection (CMR): 50 dB typical.
Frequency Response: ± 0.5 dB, 20Hz–20kHz.
Input/Output Monitor Accuracy: Typically ±1dB.
Features
• 100Mb Ethernet single-plug solution for
HiQnet or TCP/IQ control and monitoring
• Listen Bus amplifier output monitor
• 24 bit conversion with 32 bit, floating point
DSP processing
• 64 assignable filters with 9 different filter types
including all-pass filters
• Over 2 seconds of delay available per channel
• Input compressors and output limiters for
each channel
• Dual, uncorrelated noise generators for noise
masking
• Sine-wave generator
• Load supervision
• Full error reporting
• Firmware upgrades via the network
• 10 user selectable presets
• Reliable FLASH memory backup of all param-
eters
• Three Year, No-Fault, Fully Transferable Warranty
completely protects your investment and guaran-
tees its specifications
The Crown®IQ-PIP-USP3 is a 3rd genera-
tion DSP-based PIP™ (Programmable
Input Processor) input module for PIP2™
compatible amplifiers.* It connects the ampli-
fier to a 100 Mb Ethernet network allowing it
to be remotely controlled and monitored via
System Architect or IQwic software.
The USP3 is a HiQnet and TCP/IQ series com-
ponent and connects to the audio control/moni-
tor network using standard 100Mb Ethernet
hardware (switches, Network Interface Cards,
and cables).
The USP3’s SHARC DSP processor gives the
user an enormous amount of digital signal pro-
cessing. Audio routing, faders, meters, polarity
& mute, input compressors, filters, delays, mul-
timode output limiters, error reporting, and load
monitoring are all available. A built in noise gen-
erator and sine-wave generator provide noise
masking and test capabilities. The enhanced
AUX port capability allows the user to interface
with the amplifier to provide external manual
control and monitoring.
Offering crisp, clear sound and the wide
dynamic range possible with full 24-bit convert-
ers, the IQ-PIP-USP3 provides unprecedented
power and flexibility in one compact—and very
affordable—module.
The IQ-PIP-USP3 requires IQwic software avail-
able from www.iqaudiosystems.com.
For more details about the Crown IQ-PIP-USP3,
contact the Crown Technical Support Group at
800-342-6939 or 574-294-8200. Also, visit the
Crown Audio website at www.crownaudio.com.
* You must have a PIP2-compatible amplifier to use the IQ-
PIP-USP3. To determine if your amplifier is PIP2-compatible,
look for the logo on the back of the amplifier.
Specifications
General
Internal Controls: A Reset/Preset switch,
accessible with a straightened paper clip
through the PIP panel, selects the next user
preset if pressed for less than 2 seconds, resets
the PIP to preset “0” if pressed for more than
2 seconds.
Connectors:
Balanced Audio Input Connectors
3-pin removable barrier-strip connector for both
channels.
AUX Connector
Configurable for AUX input, AUX output or
Listen Bus.
Crown International
1718 W. Mishawaka Rd.
Elkhart, IN 46517-9439
TEL: 574-294-8200
FAX: 574-294-8FAX
www.crownaudio.com
7/05
Crown’s Three-Year, No-Fault, Fully Transferable Warranty
Crown offers a Three-Year, No-Fault, Fully Transferable Warranty for every new Crown IQ
component—an unsurpassed industry standard. With this unprecedented No-Fault protection,
your new Crown IQ component is warranted to meet or exceed original specifications for the
first three years of ownership. During this time, if your unit fails, or does not perform to original
specifications, it will be repaired or replaced at our expense. About the only things not covered
by this warranty are those losses normally covered by insurance and those cuased by intentional
abuse. And the coverage is transferable, should you sell your unit.
See your authorized Crown dealer for full warranty disclosure and details. For customers outside
of the USA, please contact your authorized Crown distributor for warranty information or call
574-294-8200.
Specifications subject to change without prior notice. Latest
information available at www.crownaudio.com and
www.iqaudiosystems.com.
Crown, Crown Audio and IQ are registered trademarks; PIP
and PIP2 are trademarks of Crown International. HiQnet is
a trademark of Harman International Industries, Inc. Other
trademarks are the property of their respective owners.
Printed in U.S.A.
© 2005 Crown Audio®, Inc.
IQ-PIP-USP3 SIgnal Flow Block Diagram
135808-2D
IQ-PIP-USP3

Other manuals for IQ-PIP-USP3

1

Other Crown Computer Hardware manuals

Crown IQ P.I.P.-DSP User manual

Crown

Crown IQ P.I.P.-DSP User manual

Crown IQ-P.I.P User manual

Crown

Crown IQ-P.I.P User manual

Crown PIP-USL User manual

Crown

Crown PIP-USL User manual

Crown PIP-XOV User manual

Crown

Crown PIP-XOV User manual

Crown PIP-ATX User manual

Crown

Crown PIP-ATX User manual

Crown IQ-P.I.P User manual

Crown

Crown IQ-P.I.P User manual

Crown IQ-PIP-LITE User manual

Crown

Crown IQ-PIP-LITE User manual

Crown PIP-EDCB User manual

Crown

Crown PIP-EDCB User manual

Crown IQ-PIP-USP3/CN User manual

Crown

Crown IQ-PIP-USP3/CN User manual

Crown IQ-PIP-USP2 User manual

Crown

Crown IQ-PIP-USP2 User manual

Crown IQ-P.I.P.-MEM User manual

Crown

Crown IQ-P.I.P.-MEM User manual

Crown ScreenArray PIP-3632 User manual

Crown

Crown ScreenArray PIP-3632 User manual

Crown IQ-PIP-USP2 User manual

Crown

Crown IQ-PIP-USP2 User manual

Crown PIP - LITE User manual

Crown

Crown PIP - LITE User manual

Crown IQ-P.I.P-SMT User manual

Crown

Crown IQ-P.I.P-SMT User manual

Crown IQ-PIP-USP2 User manual

Crown

Crown IQ-PIP-USP2 User manual

Crown PIP-AF User manual

Crown

Crown PIP-AF User manual

Crown PIP-XOV User manual

Crown

Crown PIP-XOV User manual

Crown P.I.P.-102 User manual

Crown

Crown P.I.P.-102 User manual

Crown PIP-EDC User manual

Crown

Crown PIP-EDC User manual

Crown PIP-FXT User manual

Crown

Crown PIP-FXT User manual

Crown IQ-PIP-LITE User manual

Crown

Crown IQ-PIP-LITE User manual

Crown PIP-FPX User manual

Crown

Crown PIP-FPX User manual

Crown IQ-P.I.P-AP Assembly instructions

Crown

Crown IQ-P.I.P-AP Assembly instructions

Popular Computer Hardware manuals by other brands

Multitech ISI551PC owner's manual

Multitech

Multitech ISI551PC owner's manual

Paradox PRT3 manual

Paradox

Paradox PRT3 manual

InWin NR24 user manual

InWin

InWin NR24 user manual

FOR-A HVS-2000MV installation guide

FOR-A

FOR-A HVS-2000MV installation guide

Ebmpapst D3G133-LV05-31 operating instructions

Ebmpapst

Ebmpapst D3G133-LV05-31 operating instructions

Contec bx200 SERIES user manual

Contec

Contec bx200 SERIES user manual

InWin IW-RT04-01 user manual

InWin

InWin IW-RT04-01 user manual

DF ROBOT BOSON KIT Starter Guide

DF ROBOT

DF ROBOT BOSON KIT Starter Guide

protech BM-0972 user manual

protech

protech BM-0972 user manual

Corsair iCUE ELITE LCD UPGRADE KIT quick start guide

Corsair

Corsair iCUE ELITE LCD UPGRADE KIT quick start guide

Contec CNT-3204MT-LPE user guide

Contec

Contec CNT-3204MT-LPE user guide

Global American Inc. 3007680 user manual

Global American Inc.

Global American Inc. 3007680 user manual

protech prox BE-U236 Quick reference guide

protech

protech prox BE-U236 Quick reference guide

Multitech MultiModem ISI5634UPCI-4 quick start guide

Multitech

Multitech MultiModem ISI5634UPCI-4 quick start guide

Black Box T1 CSU/DSU manual

Black Box

Black Box T1 CSU/DSU manual

Dolby Laboratories CP750 manual

Dolby Laboratories

Dolby Laboratories CP750 manual

Commell FS-97E user manual

Commell

Commell FS-97E user manual

Lippert PC/104-Plus Technical manual

Lippert

Lippert PC/104-Plus Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.