manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Crown
  6. •
  7. Computer Hardware
  8. •
  9. Crown IQ-PIP-USP3/CN User manual

Crown IQ-PIP-USP3/CN User manual

* You must have a PIP2-compatible amplifier to use the IQ-
PIP-USP3/CN. To determine if your amplifier is PIP2-compat-
ible, look for the logo on the back of the amplifier.
The IQ-PIP-USP3/CN is NOT compatible with older Crown
PIP amplifiers, and cannot be used with CT210 or MA3600
amplifiers
Specifications
General
Internal Controls: A Reset/Preset switch,
accessible with a straightened paper clip
through the PIP panel, selects the next user
preset if pressed for less than 2 seconds,
resets the PIP to preset “0” if pressed for more
than 2 seconds.
IQ-PIP-
USP3/CN
ULTRA SERIES
The Crown® IQ-PIP-USP3/CN is a 3rd
generationDSP-based PIP™ (Program-
mable Input Processor) input module for
PIP2™ compatible amplifiers.* It connects the
amplifier to a 100 Mb Ethernet network allow-
ing it to be remotely controlled and monitored
via System Architect or IQwic™ software. In
addition, the USP3/CN allows the transport of
real-time digital audio via CobraNet over the
same Ethernet network.
The USP3/CN is a HiQnet and TCP/IQ series
component and connects to the audio con-
trol/monitor network using a standard 100Mb
Ethernet hardware (switches, Network Interface
Cards, and cables). CobraNet™ audio is avail-
able over the same 100Mb Ethernet network,
providing a simple to install, single plug
solution for audio distribution, control, and
monitoring.
The USP3/CN’s SHARC DSP processor gives
the user an enormous amount of digital signal
processing. Audio routing, faders, meters,
polarity & mute, input compressors, filters,
delays, multimode output limiters, error report-
ing, and load monitoring are all available. A
built in noise generator and sine-wave genera-
tor provide noise masking and test capabilities.
The enhanced AUX port capability allows the
user to interface with the amplifier to provide
external manual control and monitoring.
Offering crisp, clear sound and the wide
dynamic range possible with CobraNet, the IQ-
PIP-USP3/CN provides unprecedented power
and flexibility in one compact—and very afford-
able—module.
The IQ-PIP-USP3/CN requires Harman Pro
System Architect software or IQwic software
available from www.iqaudiosystems.com.
For more details about the Crown
IQ-PIP-USP3/CN, contact the Crown Technical
Support Group at 800-342-6939 or 574-294-
8200. Also, visit the Crown Audio website at
www.crownaudio.com.
Connectors:
Balanced Audio Input Connector
Single 5-pin removable barrier-strip connector
for both channels.
AUX Connector
Configurable for AUX input or AUX output.
Listen Bus is available through CobraNet.
Network Connector
The dual RJ45 CobraNet connectors allow a
Primary & Secondary connection to the 100Mb
Ethernet network. Should the Primary con-
nection lose link activity with the network,
the USP3/CN will automatically switch to the
Secondary connection to ensure uninterrupted
audio and control. The indicators on the RJ45
connectors display network information con-
cerning the Ethernet and CobraNet connections.
Indicators:
Preset Indicator
Signals the number of the current preset, if
active, by flashing a series of flashes equal to
the current preset number.
IQ Data Indicator
Flashes when the IQ-PIP-USP3/CN receives a
valid command that is addressed to the IQ-PIP-
USP3/CN.
Switches:
Reset/Preset Switch
Used to change presets, restore settings to fac-
tory default or restore all the presets to the fac-
tory defaults. During operations of the switch,
the Data indicator flashes as an aid to the user.
Memory Backup: 512 kbyte non-volatile FLASH
memory for backup of run-time parameters,
presets, and program storage. Capable of
greater than 10 year data retention and esti-
mated 20+ year life-cycle.
Communications: 100Mb Fast Ethernet con-
forming to IEEE 802.3.
Power Requirements (provided by the ampli-
fier): +24VDC @ 350mA, –24VDC @ 30mA.
< 8.7 Watts.
Overall Audio Performance:
DSP Processing: 32 bit, Floating Point,
665 µs latency.
DAC Conversion: 24 bit, 135 µs latency.
Dynamic Range: 103 dB typical
(A-weighted, 20Hz–20kHz, audio sourced
from muted CobraNet channel).
Distortion: < 0.05% THD+N, 20Hz–20kHz.
Frequency Response: ± 0.5 dB,
20Hz–20kHz.
Input/Output Monitor Accuracy: Typically
±1dB.
Features
• 100Mb Ethernet single-plug solution for
CobraNet audio, and HiQnet or TCP/IQ control
and monitoring
• Analog audio inputs allow CobraNet network
audio input, CobraNet audio backup, or a hard-
wire emergency override of CobraNet audio
• “Listen Bus” amplifier output monitor via
CobraNet
• 24 bit digital to analog conversion with 32 bit,
floating point DSP processing
• 64 assignable filters with 9 different filter types
including all-pass filters
• Over 2 seconds of delay available per
channel
• Input compressors and output limiters for each
channel
• Dual, uncorrelated noise generators for noise
masking
• Sine generator
• Load supervision
• Full error reporting
• Firmware upgrades via the network
• 10 user selectable presets
• Reliable FLASH memory backup of all param-
eters
• Three Year, No-Fault, Fully Transferable War-
ranty completely protects your investment and
guarantees its specifications
IN USE/
CONDUCTOR
LINK/
ACTIVITY
Crown International
1718 W. Mishawka Rd.
Elkhart, IN 46517-9439
TEL: 574-294-8200
FAX: 574-294-8FAX
www.crownaudio.com
7/05
Crown’s Three-Year, No-Fault, Fully Transferable Warranty
Crown offers a Three-Year, No-Fault, Fully Transferable Warranty for every new Crown IQ com-
ponent—an unsurpassed industry standard. With this unprecedented No-Fault protection, your
new Crown IQ component is warranted to meet or exceed original specifications for the first three
years of ownership. During this time, if your unit fails, or does not perform to original specifica-
tions, it will be repaired or replaced at our expense. About the only things not covered by this
warranty are those losses normally covered by insurance and those cuased by intentional abuse.
And the coverage is transferable, should you sell your unit.
See your authorized Crown dealer for full warranty disclosure and details. For customers outside
of the USA, please contact your authorized Crown distributor for warranty information or call
574-294-8200.
Specifications subject to change without prior notice. Latest
information available at www.crownaudio.com and
iqaudiosystems.com.
Crown, Crown Audio and IQ are registered trademarks; PIP
and PIP2 are trademarks of Crown International. HiQnet is
a trademark of Harman International Industries, Inc. Other
trademarks are the property of their respective owners.
Printed in U.S.A.
© 2005 Crown Audio®, Inc.
IQ-PIP-USP3/CN SIgnal Flow Block Diagram
135809-2C
IQ-PIP-
USP3/CN
Balanced Audio Inputs:
Input Impedance: Nominally 20 k ohms
balanced, 10 k ohms unbalanced.
Maximum Input Level: + 20 dBu.
ADC Conversion: 18 bit, 312 µs latency.
Signal to Noise Ratio: 70 dB typical (A-
weighted, 20Hz-20kHz).
Crosstalk: > 60 dB @ 1kHz.
Common Mode Rejection (CMR): 50 dB typi-
cal.
Distortion: > 0.05% THD+N, 20Hz–20kHz.
Frequency Response: ± 0.5 dB, 20Hz–20kHz.

This manual suits for next models

1

Other Crown Computer Hardware manuals

Crown PIP-BEQ User manual

Crown

Crown PIP-BEQ User manual

Crown ScreenArray PIP-3632 User manual

Crown

Crown ScreenArray PIP-3632 User manual

Crown ScreenArray PIP-3632 User manual

Crown

Crown ScreenArray PIP-3632 User manual

Crown IQ-PIP-USP2 User manual

Crown

Crown IQ-PIP-USP2 User manual

Crown PIP-XOV User manual

Crown

Crown PIP-XOV User manual

Crown IQ-PIP-USP3 User manual

Crown

Crown IQ-PIP-USP3 User manual

Crown IQ-P.I.P.-SLM User manual

Crown

Crown IQ-P.I.P.-SLM User manual

Crown PIP-ATN User manual

Crown

Crown PIP-ATN User manual

Crown IQ-P.I.P.-SLM User manual

Crown

Crown IQ-P.I.P.-SLM User manual

Crown PIP-EDC User manual

Crown

Crown PIP-EDC User manual

Crown IQ-PIP-USP2 User manual

Crown

Crown IQ-PIP-USP2 User manual

Crown IQ-P.I.P.-MEM User manual

Crown

Crown IQ-P.I.P.-MEM User manual

Crown PIP-FPX User manual

Crown

Crown PIP-FPX User manual

Crown IQ-PIP-LITE User manual

Crown

Crown IQ-PIP-LITE User manual

Crown IQ-P.I.P-SMT User manual

Crown

Crown IQ-P.I.P-SMT User manual

Crown PIP-AF User manual

Crown

Crown PIP-AF User manual

Crown PIP-XOV User manual

Crown

Crown PIP-XOV User manual

Crown PIP-ATX User manual

Crown

Crown PIP-ATX User manual

Crown PIP-FXT User manual

Crown

Crown PIP-FXT User manual

Crown PIP-EDCB User manual

Crown

Crown PIP-EDCB User manual

Crown IQ-P.I.P User manual

Crown

Crown IQ-P.I.P User manual

Crown IQ-P.I.P User manual

Crown

Crown IQ-P.I.P User manual

Crown P.I.P.-102 User manual

Crown

Crown P.I.P.-102 User manual

Crown IQ-PIP-USP2 User manual

Crown

Crown IQ-PIP-USP2 User manual

Popular Computer Hardware manuals by other brands

swiftech MCW5000-PX installation guide

swiftech

swiftech MCW5000-PX installation guide

AXIOMTEK CAPA880 Series Quick installation guide

AXIOMTEK

AXIOMTEK CAPA880 Series Quick installation guide

NETGEAR MA521 - 802.11b Wireless PC Card Specifications

NETGEAR

NETGEAR MA521 - 802.11b Wireless PC Card Specifications

Alphacool GPX-A 380-M05 instruction manual

Alphacool

Alphacool GPX-A 380-M05 instruction manual

NXP Semiconductors Motorola DSP56602 user manual

NXP Semiconductors

NXP Semiconductors Motorola DSP56602 user manual

SHIFT Cryptocurrency Digital BitBox user guide

SHIFT Cryptocurrency

SHIFT Cryptocurrency Digital BitBox user guide

Gigabyte AORUS LIQUID COOLER Series Quick installation guide

Gigabyte

Gigabyte AORUS LIQUID COOLER Series Quick installation guide

junger EASY LOUDNESS manual

junger

junger EASY LOUDNESS manual

HighPoint SSD7140A Quick installation guide

HighPoint

HighPoint SSD7140A Quick installation guide

Dell PowerEdge 2600 Installing or replacing

Dell

Dell PowerEdge 2600 Installing or replacing

Microchip Technology MPLAB REAL ICE user guide

Microchip Technology

Microchip Technology MPLAB REAL ICE user guide

ekwb EK-Velocity sTR4 user guide

ekwb

ekwb EK-Velocity sTR4 user guide

Johnson Controls Frick XL Installation operation & maintenance

Johnson Controls

Johnson Controls Frick XL Installation operation & maintenance

IBM System x3630 M4 manual

IBM

IBM System x3630 M4 manual

ST X-NUCLEO-IDB04A1 user manual

ST

ST X-NUCLEO-IDB04A1 user manual

Elenco Electronics K-28 Assembly and instruction manual

Elenco Electronics

Elenco Electronics K-28 Assembly and instruction manual

Teridian 71M6531 quick start guide

Teridian

Teridian 71M6531 quick start guide

SIIG JU-PCM422-S2 Quick installation guide

SIIG

SIIG JU-PCM422-S2 Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.