manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CTC Union
  6. •
  7. Switch
  8. •
  9. CTC Union IFS+402GSM-4PHE24 User manual

CTC Union IFS+402GSM-4PHE24 User manual

Introduction
IFS+402GSM-4PH(E)24 are managed industrial grade Fast Ethernet PoE (Power
over Ethernet) switches that provide stable and reliable Ethernet transmission.
Housed in rugged DIN rail or wall mountable enclosures, these switches are
designed for harsh environments, such as industrial networking and intelligent
transportation systems (ITS) and are also suitable for many military and utility
market applications where environmental conditions exceed commercial product
specifications. Standard operating temperature range models (-10°C~60°C) and
wide operating temperature range models (-40°C~75°C) fulfill the special needs of
industrial automation applications.
Package List
IFS+402SM-4PH(E)24 device with terminal block
Console cable (RJ-45 to DB9)
Quick installation guide Protective caps for SFP slots
Din rail with screws CD (SmartConfig, MIB file, Manual)
Features
Redundant dual DC inputs 24VDC/48VDC (20~57VDC), -48VDC
Built-in very high efficiency booster (94~97%) that raises power to 53VDC for
PoE output
Regulate PoE output voltage (53VDC) to stabilize PoE devices
IP30 rugged metal housing
Wide temperature range -40°C~75°C (IFS+402GSM-4PHE24)
Support negative power input with isolated RS-232 console port
Support many advanced Ethernet L2 functions
Support IEEE1588 PTPv2 for precise time synchronization
Console, Telnet, Web and SNMP management
4KV surge protection for RJ-45, PoE and fiber ports
2.25K VDC Hi-pot isolation protection for Ethernet ports and power
Heavy Industrial grade EMS, EMI, Railway Traffic EN50121-4, N61000-6-2,
EN61000-6-4 & Safety EN60950-1
Specifications
Ethernet Interface
Standards: IEEE802.3 (10Base-T), 802.3u (100Base-TX)
4 RJ-45 (shielded) ports
Speed: 10/100M (Auto)
Optical
Standards: IEEE80802.3u (100Base-FX), 802.3z (1000Base-X)
2 SFP-based slots
Speed: 100/1000M (Manual)
Switch Features
Store & Forward Switch
Supports IEEE802.3x Flow Control
Auto MDI/MDI-X
Duplex: Full/Half (Auto-negotiation per IEEE802.3u)
Switching Fabric: 4.8Gbps (Non-blocking)
Memory Buffer: 512K Bytes
MAC Table: 8K
MTU: 64~9600 bytes
Power over Ethernet
4 PoE enabled ports, End Span Alternate A Mode
Supports IEEE802.3af 15.4watts PoE per port
Supports IEEE802.3at 30watts PoE+ per port (120W budget)
Positive (V+) pins 1, 2; Negative (V-) pins 3, 6; Data 1, 2, 3, 6
Specifications (cont.)
Power
Absolute Input Range: 24/48VDC (20~57VDC), -48VDC
Support Power Input Reverse Polarity Protection
Support Dual Power Inputs
Support Removable Terminal Block
Consumption:
Items
Input Voltage
Total Power
Consumption
Device Power
Consumption
PoE
Budget
Boost
Efficiency
24VDC
132.5W
6.5W
120W
96%
48VDC
133W
7.7W
120W
96%
Mechanical
Water & Dust Proof: IP30 Protection
Dimensions: 106 mm (D) x 62.5 mm (W) x 135 mm (H)
Mounting: DIN-Rail, Wall Mount (Optional)
Weight: 700 g
Environmental
Operating Temperature: -10°C~60°C, -40°C~75°C (IFS+402GSM-4PHE24)
Storage Temperature: -40°C~85°C
Humidity: 5%~95% (Non-condensing)
Certifications
EMC: CE
EMI (Electromagnetic Interference): FCC, FCC Part 15 Subpart B Class A, CE
EN55022 Class A
Railway Traffic: EN50121-4
Immunity for Heavy Industrial Environment: EN61000-6-2
Emission for Heavy Industrial Environment: EN61000-6-4
EMS (Electromagnetic Susceptibility) Protection Level:
EN61000-4-2 (ESD) Level 3, Criteria B
EN61000-4-3 (RS) Level 3, Criteria A
EN61000-4-4 (Burst) Level 3, Criteria A
EN61000-4-5 (Surge) Level 3, Criteria B
EN61000-4-6 (CS) Level 3, Criteria A
EN61000-4-8 (PFMF, Magnetic Field) Field Strength: 300A/m, Criteria A
Safety: EN60950-1
4KV surge protection for UTP, PoE ports and SFP
Hi Pot Protection: DC 2.25KV for power to chassis ground, Ethernet ports to
chassis ground
Shock: EN60068-2-27 Freefall: EN60068-2-32
Vibration: EN60068-2-6 MTBF (MIL-HDBK-217): 626,632 Hours
Panels
Quick Installation Guide
IFS+402GSM-4PH24
IFS+402GSM-4PHE24
Industrial 4 x 10/100Base-TX + 2 x SFP with 4 PoE Managed Switch (Hardened)
No.
Description
No.
Description
1
UTP RJ-45 ports (support PoE
function)
5
UTP RJ-45 Link/ACT & PoE LED indicators
2
SFP slots
6
Link/ACT LED indicators for fiber optic
3
Power, Fault, CPU ACT & Ring
Master LED indicators
7
Terminal block
4
Console port
8
Earth grounding connection
PoE Ports
All 4 LAN ports support PoE (Power over Ethernet) per IEEE802.3af (15.4W) or
IEEE802.3at (30W) for connection to standard PoE PD (Power Devices) such as IP
Cameras, Access Points, IP Phones, Digital Signage, etc. PoE eliminates the need to
run separate power to these devices thereby simplifying deployment and reducing
expenses.
The LAN ports may also connect to any non-PoE device for normal Ethernet
transmission without any damage to the non-PoE device or to this device.
RJ-45 Ethernet Port Pinouts RJ-45 Ethernet & PoE Pin Assignments
Pin
No.
RJ-45 Ethernet
100Base-TX
PoE Output
1
RX+
V+
2
RX-
V+
3
TX+
V-
4
-
5
-
6
TX-
V-
7
-
8
-
Console Port
The RJ-45 port labeled “Console”is an RS-232 terminal port for local
management. These models use a “light”CLI (Command Line Interface) in addition
to a user friendly Web interface and industry standard SNMP. See page 6 for basic
CLI and Web operation.
One RJ-45 to DB-9 cable is provided with this device. Console port pinouts and
RS-232 DB-9 connector are illustrated below together with RJ-45 to DB-9 signal
mapping information. Use the supplied cable to connect the RJ-45 Console port to
a console PC.
Figure 3. Console Port Pinout Figure 4. RS-232 (Female) Pinout
RJ-45 to DB-9 Signal Mapping
DB-9 (Female)
Direction
RJ-45
Signal
Pin
Pin
Signal
RXD
2
3
TXD
TXD
3
6
RXD
GND
5
5
GND
- 1 -
V1.0
- 3 -
Figure 2. Top Panel
Figure 1. Front Panel
© 2018 CTC Union Technologies Co., Ltd.
All trademarks are the property of their respective owners.
Technical information in this document is subject to change without notice.
T+886-2-26591021
F+886-2-26590237
E[email protected]
CTC Union Technologies Co., Ltd.
Far Eastern Vienna Technology Center
(Neihu Technology Park)
8F, No. 60, Zhouzi St., Neihu District, Taipei 114
Taiwan
www.ctcu.com
- 2 -
8
7
4
3
1
2
5
6
7
+ - + -
V+ V-
V+ V-
The dual power supplies of this device are completely isolated which means
your PC management device connected via the console port will not be
damaged while the device is powered up using negative -48VDC power.
Recommended Power, Alarm, Grounding Wiring Scheme
DC Power Connection
A removable terminal block on the top panel provides both power and
alarm connections. Power can be provided through the dual inputs from
separate sources (PWR1 & PWR2). One power supply is enough to power up
the device. If two power supplies are used, the device provides power
redundancy function. See the figure provided below for recommended DC
power wiring scheme.
Earth Ground Connection
An earth ground connector is provided on the top panel with an earth
ground sign next to it. Grounding the device can help to release leakage of
electricity to the earth safely so as to reduce injuries from electromagnetic
interference (EMI).
Prior to connecting to the power, it is important to connect the ground wire
to the earth. Follow steps below to install ground wire:
1. Loosen or remove the grounding screw.
2. Attach the grounding screw to the ring-type or fork-type terminal of the
grounding cable. Make sure that the grounding cable is long enough to
reach the earth.
3. Use a screwdriver to fasten the grounding screw.
Figure 10. Grounding Cable Type Figure 11. Grounding Connection
CLI & Web Basic Operation
IFS+402GSM-4PH(E)24 models are managed Fast Ethernet PoE switch
devices. Initial configuration (assignment of IP address) may be accomplished
via the RS-232 console and a PC or laptop running terminal emulation software.
Configure the terminal as follows:
115200 speed, 8 data bits, no parity, 1 stop bit, no flow control
IFS+402GSM-4PH(E)24 models use a command line interface (CLI) through
the serial port. Once the IP address has been configured, a web browser can
be used to configure the device through a more easy to use GUI (graphical
user interface). Please refer to the operation manual on the CDROM.
Using the provided console cable, connect the RJ-45 to the "CONSOLE" port
and the DB9 to PC COM port. Apply power to the switch. At the "Username:"
prompt, enter 'admin' (lower case, no quotes). Just press Enter when
prompted for password.
To set the IP address and subnet mask, issue the following commands:
Example: sets VID 1 to 192.168.0.250, subnet 255.255.255.0)
# config terminal
(config)# interface vlan 1
(config-if-vlan)# ip address 192.168.0.250 255.255.255.0
Then, press Enter.
NOTE: The factory default IP address is 10.1.1.1 with mask 255.255.255.0
Negative DC Power Connection
In some telecom applications, users may need to use negative DC power to
prevent the electrical magnetic interference. One power supply is enough to
power up the device. If two power supplies are used, the device provides
power redundancy function.
Figure 7. Recommended Negative DC Power Wiring
Alarm Relay Connection
The alarm relay contact can be wired into an alarm circuit which senses an
alarm condition when the contact is broken. The alarm relay is normally closed
when there is no alarm condition. The alarm conditions are user
programmable through management to include power, link faults or other
fault conditions. Please note that the alarm relay contact can only support 1A
current at 24VDC. Do not apply voltage and current that exceed these
specifications.
Figure 8. Alarm Relay Wiring
LED Indicators
LED
Color
Status
Definition
PWR1
PWR2
Green
On
Power is connected and active at the
PWR1/PWR2 input terminal connection.
Off
PWR1/PWR2 is not connected.
Fault
Amber
On
When one or more of the programmable alarm
conditions is active.
Off
Normal operation without faults.
Alarm conditions are all disabled.
CPU ACT
Green
On
During normal use, this LED will be lit, indicating
a healthy condition of the running CPU.
Ring
Master
Yellow
On
Lit when this unit is the 'master' in a fiber ring
and all units are configured for u-Ring or ERPS
(Ethernet Ring Protection Switching or G.8032).
100
Green
On
Lit when the LAN connected speed is 10/100M.
Off
No Ethernet link.
LAN
LINK/ACT
Green
On
Lit when the LAN port has a link.
Blinking
Blinking when there is Ethernet traffic.
FIBER
LINK/ACT
Green
On
The fiber link is up.
Blinking
Blinking when there is data traffic.
PoE
Green
On
The respective LAN port has successfully
negotiated PoE and is supplying output power to
the remote connected PD.
Blinking
One of the PoE faults (overload, short circuit,
port failure at startup) occurs.
Off
PD is not connected or output power is not
provided.
Installation
The switch comes with both wall mount and DIN rail hardware brackets.
When installing the DIN rail bracket, be sure to correctly align the orientation
pin.
Figure 12. DIN Rail Figure 13. Wall Mount
The switch with DIN Rail bracket has a steel spring in the upper rail of the
bracket. This spring is compressed for mounting and un-mounting by applying
downward force.
Figure 14. Mounting Figure 15.Un-mounting
- 6 -
www.ctcu.com
- 7 -
Ring-type
terminal
Fork-type
terminal
- 4 -
Figure 6. DC Power Connection
Figure 9. Alarm
Relay circuit
Fault
Normally Closed (NC)
- 5 -
Isolated
RS-232 Port
No Damage!
Figure 5. RS-232 Port with Isolation Protection
+ - + -
V+
V-
V-
V+

This manual suits for next models

1

Other CTC Union Switch manuals

CTC Union FRM220A-MSW-202 User manual

CTC Union

CTC Union FRM220A-MSW-202 User manual

CTC Union IGS-800C-8PH User manual

CTC Union

CTC Union IGS-800C-8PH User manual

CTC Union IFS?401F User manual

CTC Union

CTC Union IFS?401F User manual

CTC Union FSW3224 User manual

CTC Union

CTC Union FSW3224 User manual

CTC Union JB120 Series User manual

CTC Union

CTC Union JB120 Series User manual

CTC Union IGS+803SM-8PH User manual

CTC Union

CTC Union IGS+803SM-8PH User manual

CTC Union PHB-200 User manual

CTC Union

CTC Union PHB-200 User manual

CTC Union ITP-G800SM-8PH24 User manual

CTC Union

CTC Union ITP-G800SM-8PH24 User manual

CTC Union IGS-1608SM-SE User manual

CTC Union

CTC Union IGS-1608SM-SE User manual

CTC Union IFS-803GSM User manual

CTC Union

CTC Union IFS-803GSM User manual

CTC Union IFS-402GSM-4PH24 User manual

CTC Union

CTC Union IFS-402GSM-4PH24 User manual

CTC Union SB142 User manual

CTC Union

CTC Union SB142 User manual

CTC Union TSB6000 Series User manual

CTC Union

CTC Union TSB6000 Series User manual

CTC Union ITP-800-8PH24 User manual

CTC Union

CTC Union ITP-800-8PH24 User manual

CTC Union ITP-500 User manual

CTC Union

CTC Union ITP-500 User manual

CTC Union IGS?401F?4PH24 User manual

CTC Union

CTC Union IGS?401F?4PH24 User manual

CTC Union JB130 Series User manual

CTC Union

CTC Union JB130 Series User manual

CTC Union FRM220A-GSW/SNMP User manual

CTC Union

CTC Union FRM220A-GSW/SNMP User manual

CTC Union SB262 Series User manual

CTC Union

CTC Union SB262 Series User manual

CTC Union IGS-2408SM-24PH User manual

CTC Union

CTC Union IGS-2408SM-24PH User manual

CTC Union JB110 Series User manual

CTC Union

CTC Union JB110 Series User manual

CTC Union IGS-804SM-SE-8PHE User manual

CTC Union

CTC Union IGS-804SM-SE-8PHE User manual

CTC Union FRM220-10/100AS-2 User manual

CTC Union

CTC Union FRM220-10/100AS-2 User manual

CTC Union IGS-401F User manual

CTC Union

CTC Union IGS-401F User manual

Popular Switch manuals by other brands

NETGEAR GSM712 installation guide

NETGEAR

NETGEAR GSM712 installation guide

JABSCO 18680-0000 manual

JABSCO

JABSCO 18680-0000 manual

GBC 34.0109.41 quick start guide

GBC

GBC 34.0109.41 quick start guide

schmersal EX-AZM 170 operating instructions

schmersal

schmersal EX-AZM 170 operating instructions

ORiNG TES-3080-M12 Series user manual

ORiNG

ORiNG TES-3080-M12 Series user manual

Weidmüller Premium Line IE-SW-PL10M Series Hardware installation guide

Weidmüller

Weidmüller Premium Line IE-SW-PL10M Series Hardware installation guide

TP-Link TL-SF1016D Mounting guide

TP-Link

TP-Link TL-SF1016D Mounting guide

D-Link Web Smart DES-1210-52 Specifications

D-Link

D-Link Web Smart DES-1210-52 Specifications

axing premium-line Series Operation instructions

axing

axing premium-line Series Operation instructions

Omron XER6022-SS operating instructions

Omron

Omron XER6022-SS operating instructions

M-Audio AIR Hub user guide

M-Audio

M-Audio AIR Hub user guide

Lem Elettronica SCF316/8 user manual

Lem Elettronica

Lem Elettronica SCF316/8 user manual

Dell Networking S55 Specifications

Dell

Dell Networking S55 Specifications

HP PROCURVE 2610-PWR Series Management and configuration guide

HP

HP PROCURVE 2610-PWR Series Management and configuration guide

Dell Force10 Z9000 Configuration guide

Dell

Dell Force10 Z9000 Configuration guide

Lenovo ThinkSystem NE10032 installation guide

Lenovo

Lenovo ThinkSystem NE10032 installation guide

schmersal ZQ 700 AS operating instructions

schmersal

schmersal ZQ 700 AS operating instructions

Intermatic WH80 user guide

Intermatic

Intermatic WH80 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.