Cumberland 891-00516 User manual

EDGE
Models:
891-00516
Quick start
895-00692
Version 02
NOTE: For more complete information on the product, please refer to the
manual on the USB key provided with your EDGE manual or go to the
following web sites :
http://www.automatedproduction.com/en/apmanuals.php
http://www.cumberlandpoultry.com/sales-and-service/manuals.html
895-00692


Technical Specifications
Table 1 EDGE Main Controller safety ratings
Inputs:
Supply Input : 24VDC, 15W
Outputs:
Alarm relay output: 24VDC/AC ; 1.5A MAX
Operating Temperature 0 to 40°C (32 to 104°F)
Storage Temperature -20 to 50°C (-4 to 122°F)
Environment Type Indoor use only
Pollution Degree 2
Installation Category 2
Altitude 2000 Meters Max. (6561 Ft. Max)
Operating Relative
Humidity (maximum)
0 to 10°C (32 to 50°F) Non condensing
10 to 30°C (50 to 86°F) 95 % (± 3 %) Non condensing
30 to 40°C (86 to 104°F) 95 % (± 3 %) Non condensing
IP rating (IEC 60529) 54
Nema Rating (Nema 250) 12
Flame Rating (UL94) 5VA V-0
Flame Rating (IEC 60695 or IEC 60707) FV-0
IK rating (degree of mechanical protection - impact, IEC
62262)
08
Table 2 EDGE Main Controller — dimensions and weight
Enclosure dimensions Height 482 mm (19 inches)
Width 355 mm (14 inches)
Depth 152 mm (6 inches)
Weight 3719 grams (8.20 lbs)
Touch screen Size 15 inches, 12 high
Type LED
Resolution 1024 X 768
Clearance around the enclosure Top 260mm (10 inches)

Table 2 EDGE Main Controller — dimensions and weight (cont'd.)
Bottom 250mm (10 inches)
Hinge side 180mm (7 inches)
Latch side 150mm (6 inches)
EDGE 3-Slot Expansion Box - dimensions and weight
Enclosure
dimensions
Height 660 mm (26 inches)
Width 457 mm (18 inches)
Depth 279 mm (11 inches)
Weight 11 521 grams (25.4 lbs)
Clearance Top 300mm (12 inches)
Bottom 300mm (12 inches)
Hinge Side 250mm (10 inches)
Latch Side 180mm (7 inches)
EDGE 6-Slot Expansion Box - dimensions and weight
Enclosure
dimensions
Height 660 mm (26 inches)
Width 635 mm (25 inches)
Depth 279 mm (11 inches)
Weight 15966 grams (35.2 lbs)
Clearance around
the enclosure
Top 300mm (12 inches)
Bottom 300mm (12 inches)
Hinge Side 250mm (10 inches)
Latch Side 180mm (7 inches)
Table 3 6-Slot Expansion Box and 3-Slot Expansion Box ratings
6-Slot 100Vac-240Vac, ±10%,50-60Hz, 1 phase, 120W
3-Slot 100Vac-240Vac ±10%; 50-60Hz, 1 phase, 120W
On/Off outputs
NO (normally open) contact - motor/inductive load 12A MAX
(Nb of Units = Max current rating divided by the max
current of the fan multiplied by its service factor )
Ex.: 12A /(2.5 A * 1.5 SF) = 3.2, relay can drive 3 fans
Minimum load of 0.2A
NO (Normally Opened) contact - resistive load (electric
heating element)
120/208/240Vac: 12A MAX
Minimum load of 0.2A
NO (Normally Opened) contact - Tungsten load (incan-
descent and heat lamp)
120Vac; 10A MAX
208Vac; 5.7A MAX

Table 3 6-Slot Expansion Box and 3-Slot Expansion Box ratings (cont'd.)
240Vac; 5A MAX
Minimum load of 0.2A
NO (Normally Opened) contact - DC load 24Vdc; 5A MAX. ( Current reading not available in DC).
Minimum load of 0.2A
NO (normally opened) contact - LED and CCFL loads 120/208/240Vac, 750W; 920VA MAX
Minimum load of 0.2A / 25W
NO (normally opened) contact – Ballast loads 120/208/240Vac, 6A MAX
Minimum load of 0.2A
NC (Normally Closed) contact - Motor/inductive load 10 A MAX
Minimum load of 0.2A
(Nb of Units = Max current rating divided by the max
current of the fan multiplied by its service factor)
For example, 10A / (2.5 A * 1.5 SF) = 2.7; relay can
drive up 2 fans
NC (normally closed) contact - Resistive loads (electric
heating element)
120/208/240Vac, 10A MAX
NC (normally closed) contact - Tungsten load 120/208/240Vac; 3A MAX
Minimum load of 0.2A
NC (normally closed) contact - DC load 24Vdc; 5A MAX (Current reading is not available in DC)
Minimum load of 0.2A
NC (normally closed) contact - LED and CCFL loads 120/208/240Vac; 750W; 920VA MAX
Minimum load of 0.2A / 25W
NC (normally closed) contact – Ballast load 120/208/240Vac; 3A MAX
Minimum load of 0.2A
Variable outputs modules (SSR)
Resistive loads (heat lamps, heat mats, incandescent
light)
120 VAC; 2000W; 16.66A; 50/60Hz
208 VAC; 2000W; 9.61A; 50/60Hz
240 VAC; 2000W ; 8.33A; 50/60Hz
Minimum load of 0.2A

Table 3 6-Slot Expansion Box and 3-Slot Expansion Box ratings (cont'd.)
Motor/inductive load 10,5 A MAX
Minimum load of 0.2A
Full Load amperage on the motor nameplate is not the
maximum amp. When varying, the amperage might be
higher.
(Nb of Units = Max current rating divided by the max
current of the fan )
LED and CCFL loads 120/208/240Vac; 50/60Hz, 750W/ 920VA MAX
Minimum load of 0.2A / 25W
Ballast load 120Vac; 50/60Hz; 1200W; 10 MAX
208 Vac; 50/60Hz; 1040W; 5A MAX
240Vac; 50/60Hz; 720W; 3A MAX
Minimum load of 0.2A
Inputs
Temperature Compliant to GSIE temperature probes
Accuracy of ±0.1ºC in a normal operation
Allowable loss of performance in a noisy environment:
Accuracy of ±0.65ºC from initial reading with a fixed resistor of 1% precision used for test-
ing purpose.
Analog 0-5 Volts Sensor must be able to drive a 2k Ohms load, which means the sensor must drive at least
2.5mA to ensure correct readings.
Accuracy of ±30mV in a normal operation.
Allowable loss of performance in a noisy environment:
Accuracy of ±80mV from initial reading with a voltage source of 1% precision used for test-
ing purpose.
Analog 4-20mA Sensor must be able to drive a 120 Ohms load
Maximum rating: 20.8mA, 2.5V
Accuracy of ±0.2mA in a normal operation.
Allowable loss of performance in a noisy environment:
Accuracy of ±0.4mA from initial reading with a current source of 1% precision used for test-
ing purpose.
Dry contact Close contact resistance must be lower than 200 Ohms
Open contact resistance must be higher than 100k Ohms
Water meter, Pulse
speed
Max 100Hz, pulse width minimum of 3.2ms
Max 100 Ohms (close contact) and min. 100k Ohms (open contact) including the value of
the wire resistance

Variable output
module (SSR) cur-
rent sensor
Frequencies range : 40-70 Hz.
Accuracy of ±0.6A for AC load <20A in a normal environment.
Allowable loss of performance in a noisy environment:
Accuracy of ±0.8A from initial reading with a load of 1% precision used for testing purpose
Relay outputs with
current sensing
input
Accuracy of ±0.5A for AC load <20A in a normal environment.
Allowable loss of performance in a noisy environment:
Accuracy of ±0.75A from initial reading with a load of 1% precision used for testing purpose
Auxiliary outputs
0-10 VDC outputs 0-10VDC, accuracy : 1% (means, 0.1V), output impedance : 50 Ohms, Max current per
output : 20mA for each output
24 VDC outputs 24 VDC, 50 mA for each output
Operational specifications
Operating
Temperature
0 to 40°C (32 to 104°F)
Storage
Temperature
-20 to 50°C (-4 to 122°F)
Environment Type Indoor use only
Pollution Degree 2
Installation
Category
2
Altitude 2000 Meters Max. (6561 Ft. Max)
Operating Relative
Humidity
(maximum)
0 to 10°C (32 to 50°F) Non condensing
10 to 30°C (50 to 86°F) 95 % (± 3 %) Non condensing
30 to 40°C (86 to 104°F) 95 % (± 3 %) Non condensing
IP rating (IEC
60529)
54
Nema Rating
(Nema 250)
12
Flame Rating
(UL94)
5VA V-0

Flame Rating (IEC
60695 or IEC
60707)
FV-0
IK rating (degree of
mechanical protec-
tion - impact, IEC
62262)
08

Low voltage cable ratings
Table 1 communication bus — communication cables
Item Description
Cable type Twisted and shielded
Minimum gauge 1 mm2 (18 AWG)
Maximum cable length (including cable extensions) 1200 meters (4000 feet)
Certification and type CSA, CMG FT4 type, 18 AWG, 600 V, 75 °C (167 °F)
UL, AWM or CM ttype, 18 AWG, 600 V, 75 °C (167 °F)
Characteristic Impedance 120 Ω +/- 12
Inductance 0.258 µH/ft, Nominal
Mutual Capacitance 12 pf/ft @1 kHz, Nominal
Velocity of propagation 75%
Conductor DCR 6.9 Ω/1000ft @20°C, Nominal
OA Shield DCR 1.8 Ω/1000ft @20°C, Nominal
Attenuation (Max dB/100ft) 0.13 @ 125 kHz
0.25 @ 500 kHz
0.36 @ 1 MHz
Number of Twists 2.4 Twists/foot (min)
Table 2 DC Power cables
Item Description
Wire gauge 18 AWG 16* AWG 14 AWG 12 AWG 10 AWG
1 pair twisted
shielded
1 pair twisted
shielded
1 pair twisted
shielded
1 pair twisted
shielded
1 pair twisted
shielded
Max. length 150m (500 feet) 300m (1000
feet)
600m (2000
feet)
900m (3000
feet)
1200m (4000
feet)
Inductance
Nominal
0.17 μH/ft 0.174 μH/ft 0.16 μH/ft 0.16 μH/ft 0.14 μH/ft
ConductorDCR
@20°C, Nominal
6.1 Ω/1000ft 3.6 Ω/1000ft 2.6 Ω/1000ft 1.63 Ω/1000ft 1.09 Ω/1000ft
Certification and
type
CSA, TEW type, 600 V, 105 °C (221 °F)
UL, 1015 type, 600 V, 105 °C (221 °F)

*The recommended cable is AlphaWire 6451- 2 pairs:
- 1 pair 18AWG twisted shielded for Communication;
- 1 pair 15AWG twisted shielded for Power
Table 3 Other Low voltage cables
Item Description
Cable type Twisted and shielded
Minimum gauge 1 mm2 (18 AWG)
Maximum sensor cable length 150 m (500 feet)
• Sensor cables
• Potentiometer cables
• All other low voltage devices

Wiring diagram choice according to the equipment
e following table helps you select the wiring diagram to refer to in order to connect the equipment you have.
Equipment
name
On/o On/o
failsafe
Variable
0-10 VDC
Variable
with SSR
Variable
with realy
Dual
capacity
Inlet Inlet
failsafe
Inputs
interlock
option
Output
interlock
option
Pit fans X X X
Sidewall fans X X X
Stir fans X X X
Tunnel fans X X
Heaters X X X X X
Brooders X
Ceiling inlets X X potentio-
meter
Wall inlets X X potentio-
meter
Natural
curtains
X pot &
whisker
Tunnel inlets X pot. &
whisker
Natural
chimneys
X X X
Lights X
Cool cells X Water
valves:
supply,
zone drain
Mister /
fogger
X
Soaker X
Water valves X
Probe name Analog input Analog input w/24VDC
Temperature probes X
Water meters X
Humidity probes X X
Static pressure sensor X X

NOTE: For more complete information on the product,please refer to the manual on the USB key provided with your EDGE
manual or go to the following web sites :
AP website: http://www.automatedproduction.com/en/apmanuals.php
Cumberland website: http://www.cumberlandpoultry.com/sales-and-service/manuals.html








Table of contents
Other Cumberland Controllers manuals

Cumberland
Cumberland PNEG-881 User manual

Cumberland
Cumberland Smart-Flex FLX-4629 User manual

Cumberland
Cumberland Evolution 1200 Series User manual

Cumberland
Cumberland Evolution 4000 User manual

Cumberland
Cumberland EDGE 074-11793 Quick start guide

Cumberland
Cumberland Evolution Variable Output User manual

Cumberland
Cumberland Evolution Back-Up User manual

Cumberland
Cumberland Evolution S3 User manual

Cumberland
Cumberland EDGE 891-00516 Quick start guide

Cumberland
Cumberland CC2415 User manual