Ed. 0121 - 70702570 REV02 Pizzaform - Pre-installation
D Electrical connection (qualied electrician’s inspection)
√For a correct connection during the installation:
•provide a socket connecting to the electrical network near the
product.
•machines NOT for the American market - UL have the power
cable already installed; a plug (not supplied) must be t-
ted to it of suitable capacity. This operation must be carried out
by qualified personnel.
•machines for the American market - UL have NO power cable
and NO plug. Both are NOT supplied, must be fitted by qualified
personnel and must be only of the type stated in the table.
•check that the systems in the room comply with the legal
provisions in force in the country of use and meet the spec-
ifications on the serial number plate. For a correct electrical con-
nection, the appliance must:
•be included in an equipotential system in compliance with
the legislation in force. This connection must be made be-
tween the various devices with the terminal marked with the
equipotential symbol . The cable must have a maximum
cross-section of 10 mm2(in compliance with IEC EN 60335-2-
42:2003-09) and must be yellow-green;
•must be grounded to the mains (green-yellow wire);
•must be connected to a thermal dierential switch in com-
pliance with the regulations in force (0.03A A type);
•must be connected to an omnipolar circuit breaker allowing
complete disconnection in overvoltage III category conditions.
Electrical data
Model
Pizzaform Supply
V
Upper
h.elem.
W
Lower
h.elem.
W
Motor
WTot. kW
Absorbed
current
A
Cable type*
n x mm2
Cust. panel
prot.
nxA
30
single-phase 230V/50Hz 1790 1790 370 3.95 17.2 3x2,5 2 x 20
three-phase 3x230V/50Hz 1790 1790 550 4.13 10.4 4x1,5 3 x 16
three-phase 3x400V+N/50Hz
1790 1790 550 4.13 6.0 5x1 4 x 16
single-phase 208V/60Hz 1790 1790 550 4.13 19.9 3xAWG14 2 x 25
three-phase 3x208V/60Hz 1790 1790 550 4.13 11.5 4xAWG14 3 x 16
35
single-phase 230V/50Hz 1790 1790 370 3.95 17.2 3x2,5 2 x 20
three-phase 3x230V/50Hz 1790 1790 550 4.13 10.4 4x1,5 3 x 16
three-phase 3x400V+N/50Hz
1790 1790 550 4.13 6.0 5x1 4 x 16
single-phase 208V/60Hz 1790 1790 550 4.13 19.9 3xAWG14 2 x 25
three-phase 3x208V/60Hz 1790 1790 550 4.13 11.5 4xAWG14 3 x 16
40
single-phase 230V/50Hz 2400 2400 750 5.55 24.1 3x2.5 2 x 25
three-phase 3x230V/50Hz 2400 2400 750 5.55 13.9 4x2,5 3 x 16
three-phase 3x400V+N/50Hz
2400 2400 750 5.55 8.0 5x1.5 4 x 16
single-phase 208V/60Hz 2400 2400 750 5.55 26.7 3xAWG14 2 x 32
three-phase 3x208V/60Hz 2400 2400 750 5.55 15.4 4xAWG14 3 x 16
45
single-phase 230V/50Hz 2900 2900 750 6.55 28.5 3x4 2 x 40
three-phase 3x230V/50Hz 2900 2900 750 6.55 16.4 4x2,5 3 x 16
three-phase 3x400V+N/50Hz
2900 2900 750 6.55 9.5 5x1,5 4 x 16
single-phase 208V/60Hz 2900 2900 750 6.55 31.5 3xAWG12 2 x 40
three-phase 3x208V/60Hz 2900 2900 750 6.55 18.2 4xAWG12 3 x 20
50
single-phase 230V/50Hz 2900 2900 750 6.55 28.5 3x4 2 x 40
three-phase 3x230V/50Hz 2900 2900 750 6.55 16.4 4x2,5 3 x 16
three-phase 3x400V+N/50Hz
2900 2900 750 6.55 9.5 5x1,5 4 x 16
single-phase 208V/60Hz 2900 2900 750 6.55 31.5 3xAWG12 2 x 40
three-phase 3x208V/60Hz 2900 2900 750 6.55 18.2 4xAWG12 3 x 20
Checks before purchasing
* These cables can only be used if their length does not exceed 2 m between the point where the cable or its protection enters the
appliance and the entry into the plug.