NSF International requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required so that the unit
can be moved for cleaning.
2. Thisunitmustbeinstalledwithadequatebackowprotectiontocomplywithapplicablefederal,stateand
local codes.
3.Waterpipeconnectionsandxturesdirectlyconnectedtoaportablewatersupplyshallbesized,installed
andmaintainedinaccordancewithfederal,state,andlocalcodes.
3. Connect the unit to electrical outlet with appropriate amperage rating (see serial tag on machine).
4. Once power has been supplied to the unit, ip the toggle switch to the ‘ON’ position (located on the rear of the unit),
the water tank will begin to ll. When the water level in the tank reaches the probe, the heating element(s) will turn on.
5. Water in the heating tank will require approximately a half hour before reaching operating temperature (factory setting of
200°F). Where applicable, turn on the Universal Control Module (UCM). When the unit reaches operating temperature,
it will display “READY TO BREW”.
NOTE:Awaterltrationsystemmustbeusedtohelpmaintaintrouble-freeoperation.Air must be purged
from the cartridge prior to connection to equipment. Inareaswithextremelyhardwater,wehighlyrec-
ommendtheuseofaCurtisapprovedwaterlter.Forourfulllineoflters,logontowww.wilburcurtis.com.
SETUP STEPS
1. The unit should be level (left to right - front to back), on a secure surface.
2. Connect the water line to the water inlet tting on the rear of the unit. Water volume ow to the machine should be
consistent. Use tubing sized sufciently to provide a minimum ow rate of one gallon per minute.
Symbols
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
Models Included:
RTB
The Curtis G3 Brewer is Factory Pre-Set and Ready to Go… Right from the Box.
Following are the Factory Settings for the G3 Iced Tea Brewer.
• Brew Temperature = 204°F
• Brew Volume = Set to dispensing vessel requirements (2.2 liters)
Generally there will never be a reason to change the G3/Gold Cup Series default settings. However, should you need to
make slight adjustments to meet your brewing needs, programming instructions are provided later in this manual.
System Requirements:
• Water Source 20 – 90 PSI. Minimum ow rate of ½ gpm (1 gpm preferred ow rate).
• Electrical: See electrical schematic on page 8.
IMPORTANT: After
setup, run a FULL brew
cycle. Place a tea con-
tainer to catch both hot water from
the brewcone and dilution water
from spout on the front cover.
Wilbur Curtis Co., inC.
Service Manual – RTB
Important Safeguards/Symbols
This appliance is designed for commercial use. Any servicing other than cleaning and preventive maintenance should be
performed by an authorized Wilbur Curtis service technician.
• Do NOT immerse the unit in water or any other liquid
• To reduce the risk of re or electric shock, do NOT open service panels. No user serviceable parts inside.
• Keep hands and other items away from hot surfaces of unit during operation.
• Never clean with scouring powders, bleach or harsh chemicals.
CAUTION: DO NOT
connect the unit to hot
water. The inlet valve is
not rated for hot water.
CAUTION: Follow this
setup procedure before
attempting to use this
unit. Failure to follow these instruc-
tions can result in injury and/or void
of warranty.
CAUTION: Equipment
must be installed to
comply with applicable
federal, state, and local plumbing/
electrical codes having jurisdiction.
ISO 9001:2008 REGISTERED
WILBUR CURTIS CO., INC.
6913 West Acco Street
Montebello, CA 90640-5403
For the latest information go to
www.wilburcurtis.com
Tel: 800-421-6150
Fax: 323-837-2410
Forthelatestspecicationsandinformationgotowww.wilburcurtis.com
TechnicalSupport:1-800-995-0417M-F5:30am-4:00pmPT
Email: [email protected]

2
To Access Programming
Turn off (dark display) by pressing ON/OFF button (yellow). Press and hold BREW button #4 and then press and release ON/OFF button (yellow).
Continue holding the #4 button. Display will read , wait until is displayed Enter the 4-digit access code, the digits 1-4 corre-
spond to the buttons (see illustration below).
The default code set at the factory is 1-2-3-4. Then will be displayed.
All programming selections are performed with the three center buttons.
The symbols below the buttons are:
Scroll LEFT
SELECTION or ENTER to save new parameter
Scroll RIGHT
YourCurtisGeneration3BrewerisFactoryPre-SetforOptimumPerformance.
Afterconnectiontowaterandpower;thereartoggleswitchmustbeon.Youwillhearabeepsound,indicatingpowerisavailabletothecontroller.
Thecontroldisplays .PressON/OFFbuttonandthescreenwilldisplay .Afterthreeseconds, isdisplayed.
Waterwillllthetank(approximately2-3minutesdependingonwaterowrate).Whentheproperlevelisreached willappearonthe
screen.Ittakesapproximately20minutestoreachsetpointtemperatureof204°F.
Controlwilldisplay whentemperaturereachesthesetpoint(204°F).Unitisnowreadytobrew.
CURTIS <DUALDILUTION>
CURTIS
CURTIS
FILLING
CURTIS
HEATING
CURTIS
READYtoBREW
1. Brewer should be ON (Conrm at rear toggle switch, then press ON/OFF button) and Ready-to-Brew displayed.
2. Make sure tea containers are in place, sitting on the brew deck.
3. Place a paper lter in
the brew basket. Pour
leaf tea into the lter.
Place the lter into the
brew cone.
4. Slide brew cone into
brew rails.
6. Press the desired brew
button on the UCM
control panel. The brew
cycle will start.
5. Select the tea container
you wish to brew into
and rotate the brew
cone to direct the ow
into that tea container.
Tea Brewing Instructions
CAUTION HOT LIQUID, Scalding may occur. Allow the brew cone to completely drain before removing.

3
Program Menus
Program Menus
Tea By Volume
Tea Recipes
Tea By Time
Program Menus screen. Press the > button to show the next menu item.
Tea Recipes (Factory set to Standard Tea Purple)
Press to Select. Press < or > to scroll through recipes: Standard Gray, Standard Purple, Tropical Gray, Tropical
Purple, 76/308 Gray or 76/308 Purple. Press to set.
Tea Dilut Volume
Tea Dilut Delay
Tea Dilut Time
Tea by Volume: Press to select, Display will now show Push START To Begin... Press the BREW button then hot
water starts running, when desired volume is reached press BREW button again to stop the ow. Now the volume has
been set. Pressing > button will display the subsequent menu features.
Tea by Time (Factory set to 5:52 FULL, 2:56 HALF)
Press to select. By pressing < or > buttons, you can increase and decrease time. Press to set minutes and
seconds.
Tea Dilution Delay (Factory set to 0:30)
Press to Select. Press < or > buttons, to add or decrease time. Press to set. The maximum is 10 minutes.
Tea Dilution Volume: Press to Select, Display will now show Select Button... Press the desired brew button and
water will ow, when required volume is reached press BREW button again to stop the ow. Now the volume has
been set. Press > to display subsequent menu features.
Dilution Time (Factory set to 4:05 FULL, 2:02 HALF)
Press to Select. By pressing < or > buttons, you can increase and decrease time. Press to set minutes and
seconds. The maximum is 9 min, 59 sec.
Tea Dilution Stir (Factory set to Standard – Purple ON).
Press to Select. Press < or > to select between ON or OFF. Press to set.
Tea Pulse Brew (Factory set to OFF).
Press to Select. Press < or > to select ON, OFF or D. D is a manual adjust from 1 to 20 pulses with an ON time
from 5 to 150 seconds and an OFF time from 5 to 150 seconds.
Tea Fast Brew (Factory set to OFF).
Press to Select, press < or > to choose ON or OFF. Selecting ON will start hot water spraying in the brewcone rst
and then 1 minute later the dilution water will start to ow.
Tea Half Batch (Factory set to ON).
Press to Select. Press < or > to toggle between OFF and ON. This feature, when on, activates the Half Batch but-
tons or the Half Batch Shift buttons.
Tea Drip-Out (Factory set to OFF)
Press to Select. Press < or > to adjust time. Settings are OFF, up to 15 minutes, at 5 second increments.
Temperature (Factory set to 204ºF)
Press to Select. Press < or > to increase or decrease setting. Temperature range, from 170ºF to 208ºF in 2-de-
gree increments.
Energy Save Mode (Factory set to OFF)
Press to Select, < or > ON, OFF or ON 140ºF , to set. When in ON, unit will automatically shut off 4 hours
from last brew. When feature is OFF, unit does not have the energy saving mode.
In the ON 140ºF position, temperature goes down to 140ºF if unit has not brewed in 4 hours. This feature will save
energy by maintaining a lower temperature in the tank during periods of non-operation.
Brew Count Odom.
Press to Select, Shows total gallons and total brew cycles on the unit. Press ex or Reset Brew Count Total.
ContinuedonPage4
Temperature
Tea Dilut Stir
Energy Save Mode
Brew Count Odom
Tea Pulse Brew
Tea Fast Brew
Tea Drip-Out
Tea Half Batch

4
P-Maintenance
Beeper On/Off
Quality Timer
Display Brew
Time
Brew Count Total
Press to Select, Shows total gallons and total brew cycles on the unit. Cannot be reset.
Cold Brew Lock (Factory set to 5º F)
Press to select, < or > to select desired setting (CBL 5, 15 or OFF),to set.
The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point.
The rst setting is within 5 degrees of set point, next is within 15 degrees of set point, OFF is within 30 degrees of
set point for the Ready to Brew message, however it will brew at any temperature.
Master Reset
Press to display Are You Sure? Then < for Yes, > for No. When Master Reset is used, the all of the menu selec-
tions in the UCM return to factory defaults.
Service Call (Phone number Factory set to 1-800-000-0000)
Press to display number and change number or < to move place and EX to exit when complete. This number will
be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code (Factory set to 1-2-3-4)
Press to display number and change number, (the number can be changed 1 to 4) or < to move place and ex to exit
when complete.
Banner Name (Factory setting reads CURTIS)
Press to display the current banner letters. Press < or > to move cursor, press to select letters, or EX to exit
when complete. This feature allows up to 14 letters to be programmed. Programming all blanks disables Banner
Name. When a banner is set, the banner name is displayed on line one and Ready to Brew is on the second line.
P-Maintenance (Factory set to OFF)
Press to Select, Set gallons brewed to indicate P-Maintenance. Press < or > to adjust from Off to 3000 gallons.
Press to exit.
Beeper On/Off (Factory set to ON)
Press to display ON or OFF. Pressing either < or > toggles between on and off. to set. When ON, the unit will
emit a short beep each time a button is pressed.
Tea Quality Timer (Factory set to OFF)
Press to Select. Press < or > to adjust from 0 to 10 hours in 1 hour increments. Timing starts when a brew button is
pressed. When time expires, the UCM will emit an audio alarm and the words Quality Timer will appear ashing on the
screen.
Display Brew Time (Factory set to ON)
Press to display ON or OFF. Pressing either < or > toggles between on and off. When ON brew time displays and
counts down (during the brew cycle). When OFF, only the word Brewing is displayed during the brew cycle.
Display Messages (Factory set to ON)
Press to display ON or OFF. Pressing either < or > toggles between on and off. When ON, screen displays “Rinse
Server Before Brewing” message.
Model Select (Factory set to DUAL DILUTION)
Press to select, < or > to select model. The selections are: TEA/IC-1BATCH, TEA/IC-2BATCH,TEA/IC
3BATCH,TEA/IC-4BATCH,TEA-SWEET, DUAL-DILUTION, DUAL-SWEET, COMBO, COMBO/IC, and COMBO-
SWEET. Press to set. When the Model Select feature is changed, all settings are reset to the defaults of the newly
selected model.
Exit
Press to select, exits program mode and returns unit to operation.
Master Reset
Service Call
Cold Brew Lock
Access Code
Banner Name
Brew Count Total
Exit
Displ. Messages
Model Select

5
Error Message
With the G3/Gold Cup Series brewers, there are three error messages that can appear on the screen to advise the user of a malfunction. If one
of these error messages appear, the brewer will lock up and stop functioning until the error is corrected. An error message will occur under the
following conditions:
1. Water level ll error or overow. This error message occurs when the inlet valve solenoid has been on for more than
10 minutes. This error message also occurs when the valve is relling the tank during a brew cycle for more than 1½
minutes.
2. Water temperature control system error. An open probe or a break in the temperature control circuit is detected.
3. This error message indicates there is an overheating problem. The sensor is reading that temperature in the heating
tank has risen above 210ºF.
Usually the screen will display a service call phone
number. Once a malfunction is corrected, the error
message must be cleared. To reset the control panel
and return to normal operation, press the button for
5 seconds.
(800) 000-000
Over Temp Error
(800) 000-000
Sensor Err
(800) 000-000
Water Level Err
Other manuals for RTB
1
Table of contents
Other Curtis Kitchen Appliance manuals

Curtis
Curtis TLXA30 User manual

Curtis
Curtis TB User manual

Curtis
Curtis CFB3 User manual

Curtis
Curtis ThermoPro G4 User manual

Curtis
Curtis TCTS/T User manual

Curtis
Curtis TCT User manual

Curtis
Curtis Thermopro TLXA22 User manual

Curtis
Curtis FRW080 Operation manual

Curtis
Curtis G4 Series User manual

Curtis
Curtis MILANO G3 User manual