24
Main menu Submenu Description
UTI Output End xxH
(default 0H)
The time when utility end to power the load. Setting range
from 0H to 23H.
UTI Charge Start xxH
(default 0H)
The time when utility start to charge the battery. Setting
range from 0H to 23H.
UTI Charge End xxH
(default 0H)
The time when utility start to charge the battery. Setting
range from 0H to 23H.
PV Input Mode
Parallel Two solar input parallel.
Independent
(default) Two solar input independent.
AC Input Mode
APL:90-280VAC
(default) Common application. (APL: Appliances)
UPS:170-280VAC UPS application.
AC Output Volt
208VAC AC output voltage 208VAC.
230VAC(default) AC output voltage 230VAC.
240VAC AC output voltage 240VAC.
AC Output Freq
Auto(50Hz)
(default) AC output frequency 50Hz, have self-adaption function
Auto(60Hz) AC output frequency 60Hz, have self-adaption function
Fixed(50Hz) AC output frequency 50Hz,do not have self-adaption
function
Fixed(60Hz) AC output frequency 60Hz,do not have self-adaption
function
OverLoad Restart
YES(default) Enable auto restart when overload occurs.
NO Disable auto restart when overload occurs.
Swith to UTI If overload occurs in battery discharge mode, utility provides
power to the load.
OverTemp Restart YES (default) Enable auto restart when temperature occurs.
NO Disable auto restart when temperature occurs.
Buzzer ON/OFF ON (default) Alarm on.
OFF Alarm off.
Battery Type Lead_Acid Lead_Acid.
Custom Lead_Acid Self-defined Lead_Acid.
Max Charge Curr xxxA
(default 40A)
If battery type is selected as lead acid battery, this program
can be set up. Setting range is from 10A to 130A.
BulkCharge Volt
xx.xV
(default 56.4V)
If battery type is selected as “self-defined Lead_Acid”, this
program can be set up. Setting range is from 50.0V to 57.4V.
25
Main menu Submenu Description
FloatCharge Volt xx.xV
(default 54V)
If battery type is selected as “self-defined Lead_Acid”, this
program can be set up. Setting range is from 50~56V.
Battery Low Volt xx.xV
(default 46.4V)
Setting voltage point back to battery mode when selecting
ȾBAT first” or “PV first”. Setting range is from 44.4~51.4V.
BatLowCut Config
Default Setup battery low cut-off voltage.
Custom
BatLowCut Volt xx.xV (default 42.0V).
The battery low cut-off voltage’s setting range is from
42.0~44.0V. Increment of each click is 0.1V. Battery low
warning voltage is 2V more than battery low cut-off voltage.
And battery low warning return voltage is 4V more than
battery low cut-off voltage.
AC Output Mode
Single (default) Only CPS5000ECH48-P has shown AC Output Mode. The unit
works in parallel mode if setting "Parallel". Otherwise, the
unit works in single mode.
Parallel
System Time xxxx/xx/xx xx:xx:xx Setup the system time
COM Addr xxx Setup communication address
Error Description
Error code Description
Bat voltage high Battery voltage is high
Over Temperature Over temperature
Over Load Over load
Over Current Over current
AC-InOut Reverse AC input and output are reversed each otherġ
Error: 101 M3 failed to communicate with DSP
Error: 102 The sample from M3 and DSP of the battery voltage is inconsistent
Error: 103 Buck over current
Error: 116 Reverse polarity protection diode failed
Error: 117 Bus Soft-start failed
Error: 118 DC-DC boot failed
Error: 119 DC injection outrange
Error: 120 Failed to detect current
Error: 121 Communication failed between DSP and M3
Error: 122 Bus voltage is too high
Error: 127 AC Output voltage is too high
The following error code appears only in parallel mode